• Horizontal mounting of the power converter, is recommended
although it can be mounted in any position that provides unobstructed ventilation
to the fan and vent holes.
• The manufacturer suggests testing the power converter under full load
conditions in its intended mounting location. This will ensure that there is
sufficient unobstructed ventilation to the converter allowing it to operate at
its maximum rated load. Failure to provide adequate ventilation to the
converter will cause the converter output to be reduced as it responds to
ambient conditions.
• The INTELI-POWER converters are not designed for zero
clearance compartments.
• Use a 5/32” hex driver to tighten the output screws. Do
not exceed 50 in-lbs. torque on the output terminals.
• The INTELI-POWER converters are not weather tight or
designed for wet mounting locations. They must be protected from direct contact
with water.
• Avoid the introduction of foreign materials into the case
as this could damage or cause a malfunction of the converter.