APC BK650MI 650VA 400W UPS NEW BATTERY UNINTERRUPTION SUPPLY 4 SOCKETS + RS232
APC BK650MI 650VA 400W UPS NEW BATTERY UNINTERRUPTION SUPPLY 4 SOCKETS + RS232
Reference: 8308

Simpletek code 8308

Grade A Refurbished

Possible presence of purely aesthetic defects, which do not affect use, such as small pixel defects (ISO-9241-3xx standards), microscratches on the body/screen and/or other defects not visible more than 30cm from the object resulting however from wear of the object over time; the hardware is however tested, working and guaranteed (see product condition details)

General informations

Reactive power: 650VA

Warranty: 1 year (Simpletek)

Purchase invoice: must be requested at the same time as the order and will be sent via email. In the absence of billing data, a receipt will be issued which cannot be cancelled.

 ATTENTION: NEW battery.
Description

PRODUCT FEATURES

Status Display: There are LED status displays that allow you to have a quick and clear picture of the power status; while acoustic alarms signal changes in the conditions of the UPS and the mains power supply. Thanks to automatic tests, it is possible to know in advance when a battery needs to be replaced, thus optimizing: performance, duration and reliability of the battery itself. In the event of their failure, it is possible to find out about it thanks to a preventive analysis which favors timely maintenance interventions. Finally, the secondary electronics protect against peaks without reducing the charge of the battery itself for the operation of the primary electronics during a blackout.

Connectivity:
Serial: Allows management of the UPS through a serial port.
USB: Offers the possibility of managing the UPS through the USB port.


Exit:
Output power capacity: 400Watt/650VA
Configurable maximum power (watts): 400Watt / 650VA
Rated output voltage: 230V
Output frequency (synchronized with mains power): 47 – 63 Hz
Output frequency (unsynchronized): 50/60 Hz +/-1 Hz
Topology: Standby
Waveform type: Sinusoid approximation

Output Connections:
IEC 320 C13 (selector_surgetitle)
IEC Jumpers (selector_surgetitle)
IEC 320 C13 (Battery backup)
Transfer time: 6ms typical, 10ms maximum

Entrance:
Input connection type: 230V
Input Frequency: 47 – 63 Hz, 50/60 Hz ±3 Hz (automatic detection)
Plug type: IEC-320-C14
Input voltage range for operation: 180 – 266V
Adjustable input voltage range for main operation: 160 – 286V
Number of power cables: 2
Maximum input current: 7.0A

Battery and Operating Time:
Battery type: Sealed, maintenance-free, suspended electrolyte, leak-proof lead-acid battery
Typical charging time: 8 hours
Spare battery: RBC17
Expected battery life (years): 4 – 6
RBC™ quantity: 1

Communications & Management:
Interface port(s): Optional Simple Signaling RS232 cable, USB
Control panel: LED status display with active line, active battery, battery to replace and overload indicators
Audible alarm: Alarm with battery operation, distinct low battery alarm, continuous tone alarm in case of overload

Surge Protection:
Peak energy classification: 310Joule
Data line protection: Analog telephone line for telephone/fax/modem/DSL (RJ45 connector)

Physical characteristics:
Maximum height: 16.5cm
Maximum width: 9.1cm
Maximum depth: 28.4cm
Weight: 6.5kg

Environmental conditions:
Operating temperature: 0 – 40°C
Operating relative humidity: 0 – 95%
Operating height: 0-3000 meters
Storage temperature: -15 – 45°C
Storage relative humidity: 5 – 95%
Storage height: 0-15000 meters
Perceivable noise 1 meter from the surface of the unit: 45dBA

Compliance:
Certifications: A-tick, C-tick, CE, GOST, NEMKO
Possible presence of purely aesthetic defects, which do not affect use, such as small pixel defects (ISO-9241-3xx standards), microscratches on the body/screen and/or other defects not visible more than 30cm from the object resulting however from wear of the object over time; the hardware is however tested, working and guaranteed (see product condition details) Status Display: There are LED status displays that allow you to have a quick and clear picture of the power status; while acoustic alarms signal changes in the conditions of the UPS and the mains power supply. Thanks to automatic tests, it is possible to know in advance when a battery needs to be replaced, thus optimizing: performance, duration and reliability of the battery itself. In the event of their failure, it is possible to f