Features:
7 inch graphic LCD display,touch screen and function key control at the same time, more convenient and shortcut.
Three channel ECG machine with interpretation
Auto-regulation of baseline drift can effectively inhibit baseline drift, optimizing the printing position to achieve high-quality ECG.
With automatically measuring and analyzing function for ECG parameters to reduces the doctor’s burden and improves work efficiency.
With a high resolution thermal printer to print out ECG trace,describing the trace clear and accurate,annotation as well as related parameters for diagnostic reference.
12-lead ECG simultaneous acquisition.
Adapt 110-240V, 50/60Hz AC power supply.
Specifications:
Lead | standard 12 leads |
lead acquisition | synchronously 12 leads |
Input circuit | Floating; Protection circuit against Defibrillator effect |
Input Impedance | ≥50MΩ |
Input circuit current | ≤0.0.05μA |
Record mode | Automatic: 3CH×4+1R, 3CH×4, 3CHx2+2CHx3,3CHx2+2CHx3+1R,6CHX2; Manual: 3CH, 2CH, 3CH+1R, 2CH+1R; Rhythm: Any lead selectable. |
Filter | EMG Filter: 25 Hz / 30 Hz / 40Hz/75 Hz / 100 Hz / 150Hz DFT Filter: 0.05 Hz/ 0.15 Hz AC Filter: 50 Hz / 60Hz |
CMRR | >100dB |
Patient current leakage | <10μA |
Input Circuit Current | <0.05μA |
Frequency Response | 0.05Hz~150Hz (-3dB) |
Sensitivity | 2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV |
Anti-baseline Drift | Automatic |
Time constant | ≥3.2s |
Noise level | <15μVp-p |
Paper speed | 12.5 mm/s, 25 mm/s, 50 mm/s |
Recording mode | Thermal printing system |
Paper specification | 80mmx20m paper roll |
LCD display | 7”graphic LCD |
Safety classification | IEC60601-1 class I, type CF |
Power supply | AC: 100~240V, 50/60Hz, 30VA~100VA |
DC: 14.8V/2200mAh, built-in lithium battery | |
Fuse | AC220V±10% 2*Φ5×20mm,T2A/250V AC time lag |
AC110V±10% 2*Φ5×20mm,T4A/250V AC time lag |
Package List:
ECG Machine×1
ECG Lead Wire×1
Limp Clip×4
Chest Suction Ball×6
Thermal Printing Paper×1
Fuse×1
Power Cable×1
FDA Disclaimer
FDA Disclaimer:
Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.(Seller name:May City:Beijing State:Beijing Country:China Phone:+86 18108119506)
This item has been cleaned and treated according to the manufacturer's instructions.
The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606.
The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989
The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353
The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973
massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892