Features:

7 inch graphic LCD display,touch screen and function key control at the same time, more convenient and shortcut.

Three channel ECG machine with interpretation

Auto-regulation of baseline drift can effectively inhibit baseline drift, optimizing the printing position to achieve high-quality ECG.

With automatically measuring and analyzing function for ECG parameters to reduces the doctor’s burden and improves work efficiency.

With a high resolution thermal printer to print out ECG trace,describing the trace clear and accurate,annotation as well as related parameters for diagnostic reference.

12-lead ECG simultaneous acquisition.

Adapt 110-240V, 50/60Hz AC power supply.

Specifications:


Lead

standard 12 leads

lead acquisition

synchronously 12 leads

Input circuit

Floating; Protection circuit against Defibrillator effect

Input Impedance

≥50MΩ

Input circuit current

≤0.0.05μA

Record mode

Automatic: 3CH×4+1R, 3CH×4, 3CHx2+2CHx3,3CHx2+2CHx3+1R,6CHX2;

Manual: 3CH, 2CH, 3CH+1R, 2CH+1R;

Rhythm: Any lead selectable.

Filter

EMG Filter: 25 Hz / 30 Hz / 40Hz/75 Hz / 100 Hz / 150Hz

DFT Filter: 0.05 Hz/ 0.15 Hz

AC Filter: 50 Hz / 60Hz

CMRR

>100dB

Patient current leakage

<10μA

Input Circuit Current

<0.05μA

Frequency Response

0.05Hz~150Hz (-3dB)

Sensitivity

2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV

Anti-baseline Drift

Automatic

Time constant

≥3.2s

Noise level

<15μVp-p

Paper speed

12.5 mm/s, 25 mm/s, 50 mm/s

Recording mode

Thermal printing system

Paper specification

80mmx20m paper roll

LCD display

7”graphic LCD

Safety classification

IEC60601-1 class I, type CF

Power supply

AC: 100~240V, 50/60Hz, 30VA~100VA


DC: 14.8V/2200mAh, built-in lithium battery

Fuse

AC220V±10% 2*Φ5×20mm,T2A/250V AC time lag 


AC110V±10% 2*Φ5×20mm,T4A/250V AC time lag


Package List:

ECG Machine×1

ECG Lead Wire×1

Limp Clip×4

Chest Suction Ball×6

Thermal Printing Paper×1

Fuse×1

Power Cable×1


FDA Disclaimer

FDA Disclaimer:

Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.(Seller name:May City:Beijing State:Beijing Country:China Phone:+86 18108119506)

This item has been cleaned and treated according to the manufacturer's instructions.

The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606.

The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989

The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353

The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973

massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892