Hantek DSO4204C Digital Oscilloscope 4 Channels 200Mhz PC Portable USB Oscilloscopes +EXT+DVM+Auto range function


DSO4004C Series

4CH oscilloscope, with 1CH Arbitary/function waveform generator, independent keys of oscilloscope and waveform generator which is easy to operate at the same time.250MHz bandwidth, minimum measurement range 500μV /div,1GS/s sample rate,advanced digital trigger system, high trigger sensitivity, low trigger jitter,high resolution 7 inch 64K color TFT (800*480)

Features
4CH oscilloscope+EXT+AFG+DVM+auto range function

200MHz bandwidth,minimum range 500μV /div,1GS/s sample rate.

Over 32 types of auto measurement function

Advanced digital trigger system, high trigger sensitivity. 

Over 14 types of trigger function: edge, overtime, pulse, pattern, interval, etc.

Function/arbitrary signal generator 25MHz,12BitS resolution, 200MHz DDS, ARB/square wave/sine wave/triangular wave/trapezoidal wave/impulse wave/DC etc.,easy to simulate the sensor.

Integrated USB Host/Device, convenient to communicate with PC. Support U-stick storage/systerm update.

Support a variety of SCPI remote control command

Support optional RS232 port, LAN portStable and reliable quality, sturdy and durable.

Technical Parameters

ModelDSO4254CDSO4204CDSO4104CDSO4084C
Bandwidth250MHz200MHz100MHz80MHz

Horizontal

Sample Rate Range1GS/s
Waveform Interpolation(sin x)/x
Record LengthMaximum 64K samples per single-channel; 
Maximum 32K  samples per dual-channel (4K, 32K optional)
SEC/DIV Range2ns/div~100s/div
1, 2, 5 sequence

Sample Rate and

Delay Time Accuracy
±50ppm

Delta Time Measurement Accuracy

(Full Bandwidth)

Single-shot, Normal mode

± (1 sample interval +100ppm × reading + 0.6ns)

>16 averages

± (1 sample interval + 100ppm × reading + 0.4ns)
Sample interval = s/div ÷ 200
Vertical
AD Converter
8-bit resolution,
each channel sampled simultaneously
VOLTS/DIV Range500μV/div to 10V/div at input BNC
Position Range500μV/div~20mV/div, ±400mV
50mV/div~200mV/div, ±2V
500mV/div~2V/div, ±40V
5V/div~10V/div, ±50V
Selectable Analog Bandwidth Limit, typical20MHz 
Low Frequency Response (-3db)≤10Hz at BNC
Rise Time at BNC, typicalDSO4254C DSO4204CDSO4104CDSO4084C
<1.4ns≤1.8ns<3.5ns≤4.4ns
DC Gain Accuracy±3% for Normal or Average acquisition mode, 10V/div to 10mV/div
±4% for Normal or Average acquisition mode, 5mV/div to 500μV/div

Note: Bandwidth reduced to 6MHz when using a 1X probe.

Acquisition

Acquisition ModesNormal, Peak Detect, Average and HR
Acquisition Rate, typicalUp to 2000 waveforms per second per channel (Normal acquisition mode, no measurement)
Single SequenceAcquisition ModeAcquisition Stop Time

Normal, Peak Detect

Upon single acquisition on all channels simultaneously

AverageAfter N acquisitions on all channels simultaneously, N can be set to 4, 8, 16, 32, 64 or 128

Trigger

ModeAuto, Normal
LevelCH1~CH4±4 divisions from center of screen
EXT0~3.3V
Holdoff Range20ns ~ 10s
Trigger Level Accuracy
CH1~CH40.2div × volts/div within ±4 divisions from center of screen 
EXT± (6% of setting + 40mV)  
Edge Trigger
SlopeRising, Falling, Rising&Falling
Source
CH1~CH4/EXT
Pulse Width
PolarityPositive, Negative
Condition(When)<, >, !=, =
SourceCH1~CH4
Width Range8ns ~ 10s  
Resolution8ns        
Video Trigger
Signal StandardNTSC, PAL
SourceCH1~CH4
SyncScanLine, LinrNum, OddField, EvenField and AllField
Slope Trigger
SlopeRising, Falling
Condition(When)<, >, !=, =
SourceCH1 ~ CH4
Time Range8ns ~ 10s  
Resolution8ns       
Overtime Trigger
SourceCH1~CH4
PolarityPositive, Negative
Time Range8ns ~ 10s  
Resolution8ns        
Window Trigger
SourceCH1~CH4
Pattern Trigger
Pattern0: Lower level; 1: High level; 
LevelCH1~CH4
Interval Trigger
SlopeRising, Falling
Condition(When)<, >, !=, =
SourceCH1~CH4
Time Range8ns ~ 10s       
Resolution8ns            
Under Amp
PolarityPositive, Negative
Condition(When)<, >, !=, =
SourceCH1~CH4
Time Range8ns ~ 10s       
Resolution8ns            
UART Trigger
Condition(When)Start, Stop, Data, Parity Error, COM Error
Source(RX/TX)CH1~CH4
Data formatHex
Condition(When)<, >, !=, =
Data Length1 byte 
Data Length5 bit, 6 bit, 7 bit, 8 bit
Parity CheckNone, Odd, Even
Idle LevelHigh, Low
Baud Rate(Selectable)110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s
Baud Rate (Custom)300bit/s~334000bit/s
LIN Trigger
Condition(When)Interval Field, Sync Field, Id field, Sync Id Error, Identifier, Id and Data
SourceCH1~CH4
Data formatHex
Baud Rate (Selectable)110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s
Baud Rate (Custom)300bit/s~334000bit/s  
CAN Trigger
Condition(When)Start Bit, Remote Frame, Data Frame Id, Frame Id, DataFrame Id A, Error Frame, All Error, Ack Error, Overload Fram
SourceCH1~CH4
Data formatHex
Baud Rate (Selectable)10000, 20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000, 1000000
Baud Rate (Custom)5kbit/s~1Mbit/s  
SPI Trigger
Source (CS/CLK/Data)CH1~CH4
Data formatHex
Data Length4, 8, 16, 24, 32
IIC Trigger
Source (SDA/SCL)CH1~CH4
Data formatHex     
Data Index0~7
When(Condition)Start, Stop, No Ack, Address, Data, Restart
Inputs
Input CouplingDC、AC or GND
Input Impedance, DC coupled20pF±3 pF,1MΩ±2%
Probe Attenuation1X、10X
Supported Probe Attenuation Factors1X、10X、100X、1000X
Overvoltage Category300V CAT II
Maximum Input Voltage300VRMS (10X)
Measurements
Cursors

Voltage difference between cursors: △V

Time difference between cursors: △T

Reciprocal of △T in Hertz (1/ΔT)
Automatic MeasurementsFrequency, Period, Average, Pk-Pk, RMS, PeriodRms, Min, Max, RiseTime, FallTime, + Width, - Width, + Duty, - Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, PeriodAvg, FOVShoot, RPREShoot, BWidth, FRR, FFF, FRF, FFR, LRR, LRF, LFR and LFF
General Specifications
Display
Display Type7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution800 horizontal by 480 vertical pixels
Display ContrastAdjustable
Probe Compensator Output
Output Voltage, typicalAbout 2Vpp into ≥1MΩ load
Frequency, typical1kHz
Power Supply
Supply Voltage100-120VACRMS(±10%),45Hz to 440Hz,CATⅡ
120-240VACRMS(±10%),45Hz to 66Hz,CATⅡ
Power Consumption<30W
FuseT,3.15A,250V,5x20mm
Environmental
Operating Temperature0~50 °C (32~122 °F)
Storage Temperature-40~+71 °C (-40~159.8 °F)
Humidity≤+104℉(≤+40°C): ≤90% relative humidity
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity
Cooling MethodConvection
AltitudeOperating and Nonoperating3,000m(10,000 feet)

Random Vibration0.31gRMS from 50Hz to 500Hz, 
10 minutes on each axis

Nonoperating2.46gRMS from 5Hz to 500Hz
10 minutes on each axis
Mechanical ShockOperating50g, 11ms, half sine
Mechanical
Dimension318 x 110 x 150mm(L x W x H)
Weight2900g

Arbitrary Waveform Generator Mode
Waveform Frequency

Sine:         0.1Hz~25MHz

Square:     0.1Hz~10MHz

Ramp:       0.1Hz~1MHz

EXP:         0.1Hz~5MHz 
Amplitude5mV~3.5Vp-p(50Ω)
10mV~7Vp-p(High impedance)
DAC2K~200MHz adjustable
Frequency Resolution0.001
Channel1CH waveform output
Waveform Depth4KSa
Vertical Resolution12 bit
Frequency Stability<30ppm
Output Impedance
50 Ω


Product Image




Tupianku Image Hosting ServiceTupianku Image Hosting Service


Tupianku Image Hosting Service

Function Image 

Tupianku Image Hosting Service

Tupianku Image Hosting Service

Tupianku Image Hosting Service

Tupianku Image Hosting Service



Shipping: 


We will ship all items within 1-3 working days upon receipt of payment,our goal is: send faster and been received earlier .


Expedited/Standard Int'l Shipping by Fedex,DHL,TNT and EMS courier: To USA,need 3-6 business days,To other countries,need 4-8 business days normally.But sometimes int'l delivery is highly depended on the courier company and local customs/duties.


Import duties and taxes are not included in the item price or shipping charges.These charges are the buyer responsibility. 


Warranty&Return Policy: 


We encourage all customers to communicate with us through eBay messages. 

If you have any questions or comments whatsoever regarding our products or listing, we are waiting to hear from you


A 1 year warranty is offered for this product.If the product malfunctioned under proper usage per instructions


manual within the warranty period, please contact us to obtain shipping instructions and send it back at your shipping costs.


30 days evaluation and investigation takes placed after receiving your return item.A brand new replacement unit will be sent to you at our shipping costs if it meets our warranty




On Aug-24-18 at 02:48:10 PDT, seller added the following information:

DataCaciques