Feature:
 
LED backlight (new)
Larger screen: 1.5 times of F15B's (new)
Faster response time than F15(new)
Date Hold Function
Both Auto range and Manual range Selectable
Over range protection for all ranges
Polarity Indication: Indicates negative polarity
Overflow Indication
Sleep Mode /Auto Power off / Low Battery Indication
Continuity Test with Alert
Diode Test
Power Supply: 2 x AA 1.5V Battery 
(Excluding)

General Specifications: 

Maximum Voltage between any Terminal and Earth Ground: 1000 V
Display(LCD).......................................................4000 counts,updates 3/sec
Battery Type..........................................................2 AA,NEDA 15A, IEC LR6(Excluding)
Battery life.............................................................500 hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type of LED under test)
 
Temperature
Operating..............................................................0 deg to 40 deg
Storage.................................................................-30 deg to 60 deg
Relative Humidity
Operating Humidity.............................................Non-condensing≤90%at 10deg to 30deg;≤75% at 30deg to 40deg
Operating Humidity,40MC Range....................≤80% at 10deg to 30deg;≤70% at 30deg to 40deg
Altitude
Operating..............................................................2000m
Storage.................................................................12.000m
Temperature Coefficient....................................0.1×(specified accuracy)/deg(<18deg or > 28deg)
Fuse protection for current inputs....................440 mA,1000 V Fast Fuse, Fluck specified part only.
                                                                                11A,1000v Fast Fuse, Fluke specified part only.
Size(H×W×L)........................................................183×91×49.5(mm)
Weight....................................................................455g
IP Rating................................................................IP 40
Safety.....................................................................IEC 61010-1, IEC61010-2-030 600V CAT Ⅲ,1000V CATⅡ,Pollution Degree 2
Electromagnetic Environment..........................IEC 61326-1:Portable
Electromagnetic Compatibility.........................Applies to use in Korea only
                                                                               Class A Equipment(Industrial Broadcasting and Communication Equipment)

ACCURACY SPECIFICATION:

Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy

specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

Function

Range

Resolution

Accuracy

Model 15B+

Model 17B+

AC Volts (40 to 500 Hz)400.0 mV 10.1 mV

3.0 % + 3

3.0 % + 3

4.00 V 
40.00 V 
400.00 V 
1000.00 V

0.001 V 
0.01 V 
0.1 V 
1 V

1.0 % + 3

1.0 % + 3
DC Millivolts M400.0 mV0.1 mV

1.0 % + 10

1.0 % + 10
DC Volts V4.000 V 
40.00 V 
400.0 V 
1000 V
0.001 V 
0.01 V 
0.1 V 
1 V

0.5 % + 3

0.5 % + 3
Diode Test2.000 V0.001 V10 %
Temperature50 °C to 400 °C
0 °C to 50 °C 
-55 °C to 0 °C
0.1 °CNA2 % + 1 °C 
± 2 °C 
9 % + 2 °C
Resistance (Ohms)400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 30.5 % + 3 
0.5 % + 2 
0.5 % + 2 
0.5 % + 2 
0.5 % + 2 
1.5 % + 3
Capacitance50.00 nF 
500.0 nF 
5.000 µF 
50.00 µF 
100.0 µF 
1000.0µF
0.01 nF 
0.1 nF 
0.001 µF 
0.01 µF 
0.1 µF 
1µF
2 % + 5 
2 % + 5 
5 % + 5 
5 % + 5 
5 % + 5
2 % + 5 
2 % + 5 
5 % + 5 
5 % + 5 
5 % + 5
Frequency Hz (10 Hz -100 kHz)50.00 Hz 
500.0 Hz 
5.000 kHz 
50.00 kHz 
100.0 kHz
0.01 Hz 
0.1 Hz 
0.001 kHz 
0.01 kHz 
0.1 kHz
NA0.1 % + 3
Duty Cycle0.1 % to 99.9 %0.1%NA

1% typical

 

Function

Range

Resolution

Accuracy

Model 15B+

Model 17B+

AC Current (40 to 200 Hz)400.0 µA0.1 µA

1.5 % + 3

1.5 % + 3

 4000 µA1 µA  
AC Current (40 to 200 Hz)40.00 mA0.01 mA

1.5 % + 3

1.5 % + 3

 400.0 mA0.1 mA  
AC Current (40 to 200 Hz)4.000 A 10.00 A0.001 A 0.01 A

1.5 % + 3

1.5 % + 3

DC Current400.0 µA0.1 µA

1.5 % + 3

1.5 % + 3

 4000 µA1 µA  
DC Current40.00 mA0.01 mA

1.5 % + 3

1.5 % + 3


400.0 mA0.1 mA






DC Current4.000 A0.001 A

1.5 % + 3

1.5 % + 3

 10.00 A0.01 A  


Function

Overload Protection

Input Impedance (Nominal)

Common Mode Rejection Ratio

Normal Mode Rejection

AC Volts V1000 V

>10 MΩ <100 pF

>60 dB at dc, 50 or 60 Hz_
DC Volts V1000 V

>10 MΩ <100 pF

>100 dB at dc, 50 or 60 Hz>60 dB at 50 or 60 Hz
     

STANDARD ACCESSORIES

1. A Pair of Original Test leads TL75

2. FLUKE F15B+ meter

3. Original User Manual

Note:  

This meter is made by FLUKE manufacturer in China. Now China Fluke manufacturers don't provide printed English user manual. The meter comes with an English user manual printed by us. 

You can also download English user manual online: http://assets.fluke.com/manuals/151718__umeng0000.pdf


Notice:

The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.Thanks for your support!

 

Shipping:

 

 We will ship all items within 1-3 working days upon receipt of payment,our goal is: ship it as fast as we can.

Standard Shipping: To USA,UK and Australia Canada France by ePacket,need 7-15 working days. Other by China post or Singapore post ,need 15-35 working days.

Expedited/Standard Int'l Shipping by Fedex,DHL,TNT and EMS courier: To USA,need 3-6 business days,To other countries,need 4-8 business days normally.But sometimes int'l delivery is highly depended on the courier company and local customs/duties.

Import duties and taxes are not included in the item price or shipping charges.These charges are the buyer responsibility.

 

Warranty&Reture Policy:

 

We encourage all customers to communicate with us through eBay messages. If you have any questions or comments whatsoever regarding our products or listing, we are waiting to hear from you

A 1 year warranty is offered for this product.If the product malfunctioned under proper usage per instructions

manual within the warranty period, please contact us to obtain shipping instructions and send it back at your shipping costs.

30 days evaluation and investigation takes placed after receiving your return item.A brand new replacement unit will be sent to you at our shipping costs if it meets our warranty requirements.