You are bidding on 1 WORKING RFS CELLFLEX SCF12-50J D  32669 1104   40"  LENGTH    1/2" CABLE LIKE NEW

male to male diffierent N Male Coupler's

Technical Features
Cable Type Foam-Dielectric, Superflexible
Size 1/2"
Jacket Standard
Return Loss (VSWR) Performance Standard
Maximum Return Loss, dB (VSWR) Contact RFS for your VSWR performance specification for your required frequency band.
Impedance, Ohm 50 +/- 1
Maximum Frequency, GHz 11.7
Velocity, percent 82
Peak Power Rating, kW 20.5
Inner Conductor dc Resistance, ohm/1000 m (ohm/1000 ft) 2.9 (0.88)
Outer Conductor dc Resistance, ohm/1000 m (Ohm/1000 ft) 3.4 (1.04)
RF Peak Voltage, Volts 1430
Jacket Spark, Volt RMS 5000
Capacitance, pF/m (pF/ft) 82.0 (25.0)
Inductance, µH/m (µH/ft) 0.207 (0.063)
Outer Conductor Material Corrugated Copper
Inner Conductor Material Copper-Clad Aluminum Wire
Diameter over Jacket Nominal, mm (in) 13.7 (0.54)
Diameter Outer Conductor, mm (in) 12.3 (0.48)
Diameter Inner Conductor, mm (in) 3.6 (0.14)
Diameter Dielectric, mm (in) 8.3 (0.33)
Minimum Bending Radius, Repeated Bends, mm (in) 32 (1.25)
Bending Moment, N•m (lb-ft) 1.8 (1.3)
Cable Weight, kg/m (lb/ft) 0.21 (0.14)
Tensile Strength, N (lb) 650 (146)
Flat Plate Crush Strength, N/mm (lb/in) 20.4 (110)
Recommended / Maximum Clamp Spacing, m (ft) 0.30 / 0.30 (1.00 / 1.00)
Installation Temperature, °C(°F) -40 to +60 (-40 to +140)
Storage Temperature, °C (°F) -70 to +85 (-94 to +185)
Operation Temperature, °C(°F) -50 to +85 (-58 to +185)

WITH 7/16" MALE TO MALE

THE PRODUCT IS USED AND TAKEN FROM A WORKING ENVIROMENT.

10 DAY WARRANTY

 

Technical Features
Cable Type Foam-Dielectric, Superflexible
Size 1/2"
Jacket Standard
Return Loss (VSWR) Performance Standard
Maximum Return Loss, dB (VSWR) Contact RFS for your VSWR performance specification for your required frequency band.
Impedance, Ohm 50 +/- 1
Maximum Frequency, GHz 11.7
Velocity, percent 82
Peak Power Rating, kW 20.5
Inner Conductor dc Resistance, ohm/1000 m (ohm/1000 ft) 2.9 (0.88)
Outer Conductor dc Resistance, ohm/1000 m (Ohm/1000 ft) 3.4 (1.04)
RF Peak Voltage, Volts 1430
Jacket Spark, Volt RMS 5000
Capacitance, pF/m (pF/ft) 82.0 (25.0)
Inductance, µH/m (µH/ft) 0.207 (0.063)
Outer Conductor Material Corrugated Copper
Inner Conductor Material Copper-Clad Aluminum Wire
Diameter over Jacket Nominal, mm (in) 13.7 (0.54)
Diameter Outer Conductor, mm (in) 12.3 (0.48)
Diameter Inner Conductor, mm (in) 3.6 (0.14)
Diameter Dielectric, mm (in) 8.3 (0.33)
Minimum Bending Radius, Repeated Bends, mm (in) 32 (1.25)
Bending Moment, N•m (lb-ft) 1.8 (1.3)
Cable Weight, kg/m (lb/ft) 0.21 (0.14)
Tensile Strength, N (lb) 650 (146)
Flat Plate Crush Strength, N/mm (lb/in) 20.4 (110)
Recommended / Maximum Clamp Spacing, m (ft) 0.30 / 0.30 (1.00 / 1.00)
Installation Temperature, °C(°F) -40 to +60 (-40 to +140)
Storage Temperature, °C (°F) -70 to +85 (-94 to +185)