You are bidding on 1 WORKING RFS CELLFLEX SCF12-50J D 32669 1104 40" LENGTH 1/2" CABLE LIKE NEW
male to male diffierent N Male Coupler's
Cable Type | Foam-Dielectric, Superflexible |
Size | 1/2" |
Jacket | Standard |
Return Loss (VSWR) Performance | Standard |
Maximum Return Loss, dB (VSWR) | Contact RFS for your VSWR performance specification for your required frequency band. |
Impedance, Ohm | 50 +/- 1 |
Maximum Frequency, GHz | 11.7 |
Velocity, percent | 82 |
Peak Power Rating, kW | 20.5 |
Inner Conductor dc Resistance, ohm/1000 m (ohm/1000 ft) | 2.9 (0.88) |
Outer Conductor dc Resistance, ohm/1000 m (Ohm/1000 ft) | 3.4 (1.04) |
RF Peak Voltage, Volts | 1430 |
Jacket Spark, Volt RMS | 5000 |
Capacitance, pF/m (pF/ft) | 82.0 (25.0) |
Inductance, µH/m (µH/ft) | 0.207 (0.063) |
Outer Conductor Material | Corrugated Copper |
Inner Conductor Material | Copper-Clad Aluminum Wire |
Diameter over Jacket Nominal, mm (in) | 13.7 (0.54) |
Diameter Outer Conductor, mm (in) | 12.3 (0.48) |
Diameter Inner Conductor, mm (in) | 3.6 (0.14) |
Diameter Dielectric, mm (in) | 8.3 (0.33) |
Minimum Bending Radius, Repeated Bends, mm (in) | 32 (1.25) |
Bending Moment, N•m (lb-ft) | 1.8 (1.3) |
Cable Weight, kg/m (lb/ft) | 0.21 (0.14) |
Tensile Strength, N (lb) | 650 (146) |
Flat Plate Crush Strength, N/mm (lb/in) | 20.4 (110) |
Recommended / Maximum Clamp Spacing, m (ft) | 0.30 / 0.30 (1.00 / 1.00) |
Installation Temperature, °C(°F) | -40 to +60 (-40 to +140) |
Storage Temperature, °C (°F) | -70 to +85 (-94 to +185) |
Operation Temperature, °C(°F) | -50 to +85 (-58 to +185) |
WITH 7/16" MALE TO MALE
THE PRODUCT IS USED AND TAKEN FROM A WORKING ENVIROMENT.
10 DAY WARRANTY
Cable Type | Foam-Dielectric, Superflexible |
Size | 1/2" |
Jacket | Standard |
Return Loss (VSWR) Performance | Standard |
Maximum Return Loss, dB (VSWR) | Contact RFS for your VSWR performance specification for your required frequency band. |
Impedance, Ohm | 50 +/- 1 |
Maximum Frequency, GHz | 11.7 |
Velocity, percent | 82 |
Peak Power Rating, kW | 20.5 |
Inner Conductor dc Resistance, ohm/1000 m (ohm/1000 ft) | 2.9 (0.88) |
Outer Conductor dc Resistance, ohm/1000 m (Ohm/1000 ft) | 3.4 (1.04) |
RF Peak Voltage, Volts | 1430 |
Jacket Spark, Volt RMS | 5000 |
Capacitance, pF/m (pF/ft) | 82.0 (25.0) |
Inductance, µH/m (µH/ft) | 0.207 (0.063) |
Outer Conductor Material | Corrugated Copper |
Inner Conductor Material | Copper-Clad Aluminum Wire |
Diameter over Jacket Nominal, mm (in) | 13.7 (0.54) |
Diameter Outer Conductor, mm (in) | 12.3 (0.48) |
Diameter Inner Conductor, mm (in) | 3.6 (0.14) |
Diameter Dielectric, mm (in) | 8.3 (0.33) |
Minimum Bending Radius, Repeated Bends, mm (in) | 32 (1.25) |
Bending Moment, N•m (lb-ft) | 1.8 (1.3) |
Cable Weight, kg/m (lb/ft) | 0.21 (0.14) |
Tensile Strength, N (lb) | 650 (146) |
Flat Plate Crush Strength, N/mm (lb/in) | 20.4 (110) |
Recommended / Maximum Clamp Spacing, m (ft) | 0.30 / 0.30 (1.00 / 1.00) |
Installation Temperature, °C(°F) | -40 to +60 (-40 to +140) |
Storage Temperature, °C (°F) | -70 to +85 (-94 to +185) |
Operation Temperature, °C(°F) | -50 to +85 (-58 to +185) |