DSO5000P Series



  • Feature:

    • 200/100/70MHz bandwidths
    • 1GSa/s Real Time sample rate
    • Large (7.0-inch) color display, WVGA(800x480)
    • Record length up to 40K
    • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
    • USB host and device connectivity, standard
    • Multiple automatic measurements
    • Four math functions, including FFTs standard
    • Provides software for PC real-time analysis


    • ModelDSO5202PDSO5102P DSO5072P
      Acquisition
      Sample RateReal-Time Sample: 1GS/s
      Equivalent Sample: 25GS/s
      Acquisition Modes
      NormalNormal data only
      Peak DetectHigh-frequency and randon glith capture
      AverageWavefom Average, selectable 4,8,16,32,64,128
      Inputs
      Inputs CouplingAC, DC, GND
      Inpits Impendance1MΩ±2% ‖20pF±3pF
      Probe Attenuation1X, 10X
      Supported Probe Attenuation Factor1X, 10X, 100X, 1000X
      Maximum Input VoltageCAT I and CAT II: 300VRMS (10×), Installation Category;
      CAT III: 150VRMS (1×);
      Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
      Horizontal
      Sample Rate Range500MS/s--1GS/s
      Waveform Interpolation(sin x)/x
      Record Length40K
      SEC/DIV Range2ns/div to 40s/div4ns/div to 40s/div
      Sample Rate and
      Delay Time Accuracy
      ±50ppm(at over any ≥1ms time interval)
      Position Range2ns/div to 10ns/div;
      (-4div x s/div) to 20ms;
      20ns/div to 80us/div; (-8div x s/div) to 40ms;
      200us/div to 40s/div; (-8div x s/div) to 400s
      Delta Time Measurement Accuracy
      (Full Bandwidth)
      Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
      >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
      Sample interval = s/div ÷ 200
      Vertical
      Vertical Resolution8-bit resolution, all channel sampled simultaneously
      Position Range2mV/div to 200mV/div, ±2V
      200mV/div to 5V/div, ±50V
      Bandwidth200MHz100MHz70MHz
      Rise Time at BNC( typical)1.8ns3.5ns5ns
      Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V
      500mV/div to 2V/div, ±40V; 5V/div, ±50V
      Math+, -, *, /, FFT
      FFTWindows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
      1024 sample point
      Bandwidth Limit20MHz
      Low Frequency Response (-3db)≤10Hz at BNC
      DC Gain Accuracy±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
      ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
      DC Measurement Accuracy,
      Average Acquisition Mode
      When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
      When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
      Volts Measurement Repeatability,
      Average Acquisition Mode
      Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
      Trigger System
      Trigger TypesEdge, Video, Pulse, Slope, Over time, Alternative
      Trigger SourceCH1, CH2, EXT, EXT/5, AC Line
      Trigger ModesAuto, Normal, Single
      Coupling TypeDC, AC, Noise Reject, HF Reject, LF Reject
      Trigger Sensitivity
      (Edge Trigger Type)
      DC(CH1,CH2):
      1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
      DC(EXT):
      200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
      DC(EXT/5):
      1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
      AC: Attenuates signals below 10Hz;
      HF Reject: Attenuates signals above 80kHz;
      LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
      Trigger Level RangeCH1/CH2: ±8 divisions from center of screen;
      EXT: ±1.2V;
      EXT/5:±6V
      Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20nsCH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
      EXT: ± (6% of setting + 40mV);
      EXT/5: ± (6% of setting + 200mV);
      Set Level to 50%(typical)Operates with input signals ≥50Hz
      Video Trigger
      Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions;
      EXT: 400mV;
      EXT/5: 2V
      Signal Formats and Field Rates, Video Trigger TypeSupports NTSC, PAL and SECAM broadcast systems for any field or any line
      Holdoff Range100ns ~ 10s
      Pulse Width Trigger
      Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulse
      Pulse Width Trigger PointEqual: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
      Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
      Less than: The trigger point is the trailing edge.
      Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
      Pulse Width Range20ns ~ 10s
      Slope Trigger
      Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slope
      Slope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.
      Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
      Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
      Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
      Time Range20ns ~ 10s
      Overtime Trigger
      Over Time ModeRising edge or Falling edge
      Time Range20ns ~ 10s
      Alternative Trigger
      Trigger on CH1Internal Trigger: Edge, Pulse Width, Video, Slope
      Trigger on CH2Internal Trigger: Edge, Pulse Width, Video, Slope
      Trigger Frequency Counter
      Readout Resolution6 digits
      Accuracy (typical)±30ppm (including all frequency reference errors and ±1 count errors)
      Frequency RangeAC coupled, from 4Hz minimum to rated bandwidth
      Signal SourcePulse Width or Edge Trigger modes: all available trigger sources
      The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
      Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
      Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
      Video Trigger mode: The Frequency Counter does not work.
      Measure
      Cursor MeasurementVoltage difference between cursors: △V
      Time difference between cursors: △T
      Reciprocal of △T in Hertz (1/ΔT)
      Auto MeasuermentFrequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
      Display
      Display Type7 inch 64K color TFT (diagonal liquid crystal)
      Display Resolution800 horizontal by 480 vertical pixels
      Display ContrastAdjustable (16 gears) with the progress bar
      Probe Compensator Output
      Output Voltage( typical)About 5Vpp into ≥1MΩ load
      Frequency(typical)1kHz
      Power Supply
      Supply Voltage100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ
      120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ
      Power Consumption<30W
      Fuse2A, T rating, 250V
      Environmental
      TemperatureOperating: 32℉ to 122℉ (0℃ to 50℃);
      Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
      Cooling MethodConvection
      Humidity+104℉ or below (+40℃ or below): ≤90% relative humidity;
      106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
      AltitudeOperating: Below 3,000m (10,000 feet);
      Nonoperaring: Below 15,000m(50,000 feet)
      Mechanical
      SizeLength 385mm, Width 200mm, Height 245mm
      Weight3.5KG(with Packing); 2.08KG(without Packing)