CONNECTION :
  • 1. Green is SIGNAL wire (TA).
  • 2. Black is GROUND wire (-12V).
  • 3. Red is IGNITION wire (+12V).
  • 4. White connect to Your switchable item (max 10A).
  • 5. Brown is OUT-NO (normal open contacts) , of Your choice connect positive or negative power source that need to on Your switchable item (max 10A).
  • 6. Inside the RPM switch box , is additional OUT-NC (normal close contacts) , if connect there , You can disconnect switchable item of Your choise when RPM switch activating (max 10A).

  • When you reach set engine RPM , You can ON or OFF almost any switchable item whatever you want example :
  • VTEC solenoid ; any Lights ; Horn ; Turbo activator ; cooling fan ;
  • car windows and other.

Specification :
  • Input voltage  12-24v
  • Minimum input voltage  ~7 V
  • Maximum input voltage  ~28 V
  • Maximum load  ~10A (amperes)
  • RPM switch operating amplitude from  ~500 to ~10000 RPM
  • Box dimensions  85x35x24mm (L x W x H)
  • Cables length  ~150cm