Free and Fast shipping from USA

Product Description

The XR06CX, format 32x74x60 mm, is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. It has three relay outputs to control compressor, fan, and defrost, which can be either electrical or reverse cycle (hot gas). It is also provided with 2 NTC probe inputs, the first one for temperature control, the second one, to be located onto the evaporator, to control the defrost termination temperature and to managed the fan and it's provided with a configurable digital input. With the HOTKEY it's possible to program the instrument in a quick and easy way.
 
Suitable for appliances including
for applications on medium or low temperature ventilated refrigerating units
 
 
Specification
Producer: DIXELL
Type: XR06CX-4N1F1
Mounting Measurements: 71mm x 29mm
Built-in Depth: 56mm
Supply: 110V
Voltage Type: AC
Probe Type: NTC (probes not included)
Number of Relay Outputs: 1
Relay Output 1: NO-20A(8)
Input: 1NTC
Kind of Protection: IP54
Version: Defrosting Function / Time Control
Measuring Range: -40°C up to +110°C
Display: 2½ Digit
 
Defrost
Two defrost modes are available through the td parameter:
• td=EL defrost through electrical heater (compressor OFF);
• td=in hot gas defrost (compressor ON).
Other parameters are used to control the interval between defrost cycles (id), its maximum
length (Md) and two defrost modes: timed or controlled by the evaporator's probe. At the end
of defrost dripping time is started, its length is set in the dt parameter. With dt=0 the dripping
time is disabled.
 
With FC parameter it can be selected the fans functioning
• FC=cn will switch ON and OFF with the compressor and not run during defrost
• FC=on fans will run even if the compressor is off, and not run during defrost
After defrost, there is a timed fan delay allowing for drip time, set by means of the Fd
parameter.
• FC=cy fans will switch ON and OFF with the compressor and run during defrost
• FC=oY fans will run continuously also during defrost.
An additional parameter FS provides the setting of temperature, detected by the evaporator
probe, above which the fans are always OFF. This is used to make sure circulation of air only if
his temperature is lower than set in FS.

FANS AND DIGITAL INPUT
When the digital input is configured as door switch iF=do, fans and compressor status
depends on the dC parameter value:
dC=no normal regulation;
dC=Fn fans OFF;
dC=cP compressor OFF;
dC=Fc compressor and fans OFF.
When rd=y, the regulation restart with door open alarm
 
SAFETY PRECAUTIONS
• Check the supply voltage is correct before connecting the instrument.
• Do not expose to water or moisture: use the controller only within the operating limits avoiding
sudden temperature changes with high atmospheric humidity to prevent formation of
condensation.
• Warning: disconnect all electrical connections before any kind of maintenance.
• Fit the probe where it is not accessible by the End User. The instrument must not be opened.
• In case of failure or faulty operation send the instrument back to the distributor or to “Dixell
S.r.l.” (see address) with a detailed description of the fault.
• Consider the maximum current which can be applied to each relay (see Technical Data).
• Ensure that the wires for probes, loads and the power supply are separated and far enough
from each other, without crossing or intertwining.
• In case of applications in industrial environments, the use of mains filters (our mod. FT1) in
parallel with inductive loads could be useful.
 
Package Include
1 X Dixell XR06CX Digital Thermostat Controller(Whole package with accessories)
  • Local pickup not available. 

We will ship the item you order within 1 business day upon payment.


1.Simply send your order back within 30 days and you will get a return or an exchange.
2.All we ask is you send it back in the same condition it was received - new and unused.
3.Buyer is responsible for all related shipping cost. If it is the buyer’s reason for the return or replacement, the buyer will related shipping cost.


We will do everything we can to give you a satisfying experience.
Please don't open any return request before contact us.
We do our best to resolve any issue. Leaving negative feedback and low ratings doesn't get things solved.