Features
Stable performance, multiple working modes to choose from
3 working modes, P0/self-locking/trigger start running, P1/pointing/release stop, M5/for harvester fan
P0 signal only needs to be triggered once, the module is self-locking to run all the time.
When P1 has a positive signal, the motor will turn forward; when there is a reverse signal, the motor will turn backward.
M5 This version is to reverse the motor after a period of positive rotation, and so on. The purpose of reversing is to eliminate debris.
 
Specification
Voltage: 12V, 24V
Peak current:80A
Input signal: low level (default)
Working mode: P0/Self-locking/trigger start operation
P1/pointing/release to stop
M5/Harvester fan special
Hole diameter:3.6mm
 
Working mode description:
P0 standard version-self-locking.
P0 standard version-self-locking, the signal only needs to be triggered once, the module self-locking has been running.
When the positive rotation meets the reversing signal, it will stop immediately after 0.3 seconds to enter the reverse rotation.
Limit signal priority, when positive rotation encounters positive rotation limit signal will stop immediately.
Forward rotation cannot be started when there is a forward rotation limit signal. -Reverse rotation is the same.
The forward signal and reverse signal are valid when they are low, i.e. a short OV level (negative of power supply) will start.
The limit signal is normally open type. (For example, when SW1 switch is closed or access low level, it is not possible to start the positive rotation)
 
P1 version:
When there is a positive signal, the motor turns forward; when there is a reverse signal, the motor turns backward.
No positive signal and no reverse signal, the motor stops.
When forward, if SW1 is closed, it will stop forward rotation; when reverse, if SW2 is closed, it will stop forward rotation. Withdraw the signal of SW1 SW2, it will not resume
It is necessary to re-input a signal edge in K1 or K2 to start forward and reverse rotation.
Other features are the same as for P0.
 
M5/Harvester cooling fan-specific function description:
This version is to reverse the rotation after a period of positive rotation and so on. The purpose of reversing is to remove debris.
Under normal circumstances, the lines 1, 2, 3, 4 are not required to be connected, the module will enter normal mode when powered on. When the dirt is relatively fast, you need to connect this jumper, the grading instructions are as follows for reference.
X - not connected, normal mode, every 10 minutes reverses 1 time
1 - clean, reversing 1 time every 8 minutes
2 - normal, reversing once every 6 minutes
3 - Dirtier, 1 reversal every 4 minutes
4 - serious, every 2 minutes reversed 1 time
Note: Do not connect multiple strips together, the longest time strip prevails
 
List
1 x Module
  • We accept PayPal only. But we only Accept your Ebay Address,Please Make sure it's 100% right.
  • Payment must be received in 5 business days of auction closing.
  • Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
  • Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.

Fill your shipping info

  • All package need to wait 30 days(US only need 7-10 days),Please take care it.Less than 30 days,we can't take a refund.
  • If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it.
  • If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.

DataCaciques