BROCADE VDX 6740 BR-VDX6740-24-F80-1007295-03 48-Port 10GbE SFP+4x 40GbE Switch

Up for sale is a BROCADE VDX 6740 BR-VDX6740-24-F80-1007295-03 48-Port 10GbE SFP+4x 40GbE Switch .  This item has been TESTED, POWERED ON, FACTORY RESET, and all ports and lights are shown to be FULLY FUNCTIONAL. This item is in GOOD physical CONDITION with minor scratches, scrapes, and scuffs from previous usage and storage. 

 

This item DOES NOT come with a POWER CABLE.  NO OTHER accessories are included with this item. Please refer to listing's pictures for more details.  

 

You get exactly what you see in the pictures. Please see the pictures for more details.

The best descriptions are in the pictures. Please see the pictures for a better understanding of the item's condition.

 

We do our best to describe each item. If you have any questions, feel free to contact us prior to making a purchase. 

Please contact us if you have any issues with your purchase before leaving a review. We try our best to resolve all issues.

 

 

 

 

sw0# show version

 

Network Operating System Software

Network Operating System Version: 4.1.3

Copyright (c) 1995-2014 Brocade Communications Systems, Inc.

Firmware name:      4.1.3b

Build Time:         23:54:42 Apr  9, 2015

Install Time:       19:37:14 May 19, 2015

Kernel:             2.6.34.6

 

BootProm:           1.0.1

Control Processor:  e500mc with 4096 MB of memory

 

Appl     Primary/Secondary Versions

------------------------------------------

NOS      4.1.3b

         4.1.3b

 

 

 

 

 

sw0# show chassis

 

Chassis Name:   BR-VDX6740

switchType: 131

 

FAN  Unit: 1

Time Awake:             0 days

 

FAN  Unit: 2

Time Awake:             0 days

 

POWER SUPPLY  Unit: 1

Factory Part Num:       23-1000043-01

Factory Serial Num:

Time Awake:             0 days

 

POWER SUPPLY  Unit: 2

Factory Part Num:       23-1000043-01

Factory Serial Num:

Time Awake:             0 days

 

CHASSIS/WWN  Unit: 1

Power Consume Factor:   0

Factory Part Num:       40-1000927-06

Factory Serial Num:     CPL3806L05L

Manufacture:            Day: 18  Month: 12  Year: 14

Update:                 Day: 28  Month: 12  Year: 2016

Time Alive:             580 days

Time Awake:             0 days

 

Airflow direction : Port side INTAKE

 

 

 

 

sw0# show cipherset

RADIUS Cipher is not configured

LDAP Cipher is not configured

SSH Cipher is not configured

sw0#

sw0#

sw0#

sw0# show cli

autowizard            false

complete-on-space     false

history               100

idle-timeout          600

ignore-leading-space  false

output-file           terminal

paginate              true

prompt1               \H\M#

prompt2               \H(\m)#

screen-length         24

screen-width          80

service prompt config true

show-defaults         false

terminal              unknown

 

 

 

 

sw0# show dot1x

802.1X Port-Based Authentication: Disabled

PAE Capability:                   Authenticator Only

Protocol Version:                 2

Auth Server:                      RADIUS

Readiness test timeout:           10

 

 

 

 

sw0# show firmwaredownloadhistory

 

Firmware version history

 

Sno   Date & Time                      Switch Name                      Slot PID    OS Version

1     Tue May 19 19:35:28 2015         VDX2                             0    1752   4.1.3b

2     Thu Feb  5 13:17:54 2015         sw0                              0    1817   4.0.1

 

 

 

 

sw0# show firmwaredownloadstatus

 

[1]: Tue May 19 19:33:17 2015

Slot SWITCH/0: Firmware install begins.

 

[2]: Tue May 19 19:37:47 2015

Slot SWITCH/0: Firmware install ends.

 

[3]: Tue May 19 19:37:47 2015

Slot SWITCH/0: Firmware starts to swap.

 

[4]: Tue May 19 19:37:59 2015

Slot SWITCH/0: Firmware is swapped.

 

[5]: Tue May 19 19:37:59 2015

Slot SWITCH/0: The blade begins to reboot.

 

[6]: Tue May 19 19:42:55 2015

Slot SWITCH/0: Firmware commit begins.

 

[7]: Tue May 19 19:44:38 2015

Slot SWITCH/0: Firmware commit ends.

 

[8]: Tue May 19 19:44:38 2015

Slot SWITCH/0: Firmware is downloaded successfully.

 

 

 

 

 

sw0# show global-running-config

no fsb enable

logging raslog console INFO

logging auditlog class SECURITY

logging auditlog class CONFIGURATION

logging auditlog class FIRMWARE

logging syslog-facility local LOG_LOCAL7

logging syslog-client localip MM_IP

no support autoupload enable

support ffdc

snmp-server contact "Field Support."

snmp-server location "End User Premise."

snmp-server sys-descr "Brocade VDX Switch."

snmp-server community ConvergedNetwork

snmp-server community OrigEquipMfr rw

snmp-server community "Secret C0de" rw

snmp-server community common

snmp-server community private rw

snmp-server community public

snmp-server user snmpadmin1 groupname snmpadmin

snmp-server user snmpadmin2 groupname snmpadmin

snmp-server user snmpadmin3 groupname snmpadmin

snmp-server user snmpuser1

snmp-server user snmpuser2

snmp-server user snmpuser3

line vty

 exec-timeout 10

!

zoning enabled-configuration cfg-name ""

zoning enabled-configuration default-zone-access allaccess

zoning enabled-configuration cfg-action cfg-save

role name admin desc Administrator

role name user desc User

aaa authentication login local

aaa accounting exec default start-stop none

aaa accounting commands default start-stop none

service password-encryption

username admin password "BwrsDbB+tABWGWpINOVKoQ==\n" encryption-level 7 role admin desc Administrator

username user password "BwrsDbB+tABWGWpINOVKoQ==\n" encryption-level 7 role user desc User

cee-map default

 precedence 1

 priority-group-table 1 weight 40 pfc on

 priority-group-table 15.0 pfc off

 priority-group-table 15.1 pfc off

 priority-group-table 15.2 pfc off

 priority-group-table 15.3 pfc off

 priority-group-table 15.4 pfc off

 priority-group-table 15.5 pfc off

 priority-group-table 15.6 pfc off

 priority-group-table 15.7 pfc off

 priority-group-table 2 weight 60 pfc off

 priority-table 2 2 2 1 2 2 2 15.0

 remap fabric-priority priority 0

 remap lossless-priority priority 0

!

fcoe

 fabric-map default

  vlan 1002

  priority 3

  virtual-fabric 128

  fcmap 0E:FC:00

  max-enodes 0

  enodes-config local

  advertisement interval 8000

  keep-alive timeout

 !

 map default

  fabric-map default

  cee-map default

 !

!

interface Vlan 1

!

protocol lldp

 advertise dcbx-fcoe-app-tlv

 advertise dcbx-fcoe-logical-link-tlv

 advertise dcbx-tlv

 system-description Brocade-VDX-VCS 100

!

vlan dot1q tag native

port-profile UpgradedVlanProfile

 vlan-profile

  switchport

  switchport mode trunk

  switchport trunk allowed vlan all

 !

!

port-profile default

 vlan-profile

  switchport

  switchport mode trunk

  switchport trunk native-vlan 1

 !

!

port-profile-domain default

 port-profile UpgradedVlanProfile

!

class-map cee

!

class-map default

!

 

 

 

 

 

sw0# show interface status

--------------------------------------------------------------------------------

Port         Status        Mode      Speed   Type           Description

--------------------------------------------------------------------------------

Fo 2/0/49    sfpAbsent     --         --       --                               

Fo 2/0/50    sfpAbsent     --         --       --                               

Fo 2/0/51    sfpAbsent     --         --       --                               

Fo 2/0/52    sfpAbsent     --         --       --                               

Te 2/0/1     sfpAbsent     --         --       --                               

Te 2/0/2     sfpAbsent     --         --       --                               

Te 2/0/3     sfpAbsent     --         --       --                               

Te 2/0/4     sfpAbsent     --         --       --                               

Te 2/0/5     sfpAbsent     --         --       --                               

Te 2/0/6     sfpAbsent     --         --       --                               

Te 2/0/7     sfpAbsent     --         --       --                               

Te 2/0/8     sfpAbsent     --         --       --                               

Te 2/0/9     sfpAbsent     --         --       --                               

Te 2/0/10    sfpAbsent     --         --       --                               

Te 2/0/11    sfpAbsent     --         --       --                               

Te 2/0/12    sfpAbsent     --         --       --                               

Te 2/0/13    sfpAbsent     --         --       --                               

Te 2/0/14    sfpAbsent     --         --       --                               

Te 2/0/15    sfpAbsent     --         --       --                               

Te 2/0/16    sfpAbsent     --         --       --                               

Te 2/0/17    sfpAbsent     --         --       --                               

Te 2/0/18    sfpAbsent     --         --       --                               

Te 2/0/19    sfpAbsent     --         --       --                               

Te 2/0/20    sfpAbsent     --         --       --                               

Te 2/0/21    sfpAbsent     --         --       --                               

Te 2/0/22    sfpAbsent     --         --       --                               

Te 2/0/23    sfpAbsent     --         --       --                               

Te 2/0/24    sfpAbsent     --         --       --                               

Te 2/0/25    sfpAbsent     --         --       --                               

Te 2/0/26    sfpAbsent     --         --       --                               

Te 2/0/27    sfpAbsent     --         --       --                               

Te 2/0/28    sfpAbsent     --         --       --                               

Te 2/0/29    sfpAbsent     --         --       --                               

Te 2/0/30    sfpAbsent     --         --       --                               

Te 2/0/31    sfpAbsent     --         --       --                               

Te 2/0/32    sfpAbsent     --         --       --                               

Te 2/0/33    sfpAbsent     --         --       --                               

Te 2/0/34    sfpAbsent     --         --       --                               

Te 2/0/35    sfpAbsent     --         --       --                               

Te 2/0/36    sfpAbsent     --         --       --                               

Te 2/0/37    sfpAbsent     --         --       --                               

Te 2/0/38    sfpAbsent     --         --       --                               

Te 2/0/39    sfpAbsent     --         --       --                               

Te 2/0/40    sfpAbsent     --         --       --                               

Te 2/0/41    sfpAbsent     --         --       --                               

Te 2/0/42    sfpAbsent     --         --       --                               

Te 2/0/43    sfpAbsent     --         --       --                               

Te 2/0/44    sfpAbsent     --         --       --                               

Te 2/0/45    sfpAbsent     --         --       --                               

Te 2/0/46    sfpAbsent     --         --       --                               

Te 2/0/47    sfpAbsent     --         --       --                               

Te 2/0/48    sfpAbsent     --         --       --

 

 

 

 

sw0# show inventory

 

 

NAME:FAN 1              DESCR:Chassis Fan module

PN:N/A                  SN:N/A

 

NAME:FAN 2              DESCR:Chassis Fan module

PN:N/A                  SN:N/A

 

NAME:POWER SUPPLY 1     DESCR:Chassis PS module

PN:23-1000043-01        SN:N/A

 

NAME:POWER SUPPLY 2     DESCR:Chassis PS module

PN:23-1000043-01        SN:N/A

 

NAME: Chassis           DESCR:System Chassis

SID:BR-VDX6740          SwitchType:131

PN:40-1000927-06        SN:CPL3806L05L

 

 

 

 

 

sw0# show license

 

rbridge-id: 2

xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx

       10G Port Upgrade license

       License has expired

       Feature name:PORT_10G_UPGRADE

       LICENSE IS INVALID

       Capacity: 8

xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx

       40G Port Upgrade license

       License has expired

       Feature name:PORT_40G_UPGRADE

       LICENSE IS INVALID

       Capacity: 2

 

 

 

 

sw0# show local-running-config

diag post rbridge-id 2

 enable

!

dpod 2/0/1

!

dpod 2/0/2

!

dpod 2/0/3

!

dpod 2/0/4

!

dpod 2/0/5

!

dpod 2/0/6

!

dpod 2/0/7

!

dpod 2/0/8

!

dpod 2/0/9

!

dpod 2/0/10

!

dpod 2/0/11

!

dpod 2/0/12

!

dpod 2/0/13

!

dpod 2/0/14

!

dpod 2/0/15

!

dpod 2/0/16

!

dpod 2/0/17

!

dpod 2/0/18

!

dpod 2/0/19

!

dpod 2/0/20

!

dpod 2/0/21

!

dpod 2/0/22

!

dpod 2/0/23

!

dpod 2/0/24

!

dpod 2/0/25

!

dpod 2/0/26

!

dpod 2/0/27

!

dpod 2/0/28

!

dpod 2/0/29

!

dpod 2/0/30

!

dpod 2/0/31

!

dpod 2/0/32

!

dpod 2/0/33

!

dpod 2/0/34

!

dpod 2/0/35

!

dpod 2/0/36

!

dpod 2/0/37

!

dpod 2/0/38

!

dpod 2/0/39

!

dpod 2/0/40

!

dpod 2/0/41

!

dpod 2/0/42

!

dpod 2/0/43

!

dpod 2/0/44

!

dpod 2/0/45

!

dpod 2/0/46

!

dpod 2/0/47

!

dpod 2/0/48

!

dpod 2/0/49

!

dpod 2/0/50

!

dpod 2/0/51

!

dpod 2/0/52

!

switch-attributes 2

 chassis-name VDX6740

 host-name sw0

!

fabric route mcast rbridge-id 2

!

rbridge-id 2

 ip route 0.0.0.0/0 10.76.47.1

 switch-attributes chassis-name VDX6740

 switch-attributes host-name sw0

 system-monitor fan threshold marginal-threshold 1 down-threshold 2

 system-monitor fan alert state removed action raslog

 system-monitor power threshold marginal-threshold 1 down-threshold 2

 system-monitor power alert state removed action raslog

 system-monitor temp threshold marginal-threshold 1 down-threshold 2

 system-monitor cid-card threshold marginal-threshold 1 down-threshold 2

 system-monitor cid-card alert state none action none

 system-monitor sfp alert state none action none

 system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0

 system-monitor MM threshold marginal-threshold 1 down-threshold 0

 system-monitor LineCard threshold marginal-threshold 1 down-threshold 2

 system-monitor LineCard alert state none action none

 system-monitor SFM threshold marginal-threshold 1 down-threshold 2

 no protocol vrrp

 no protocol vrrp-extended

 fcoe

  fabric-map default

   fcoe-enodes 0

  !

 !

!

interface Management 2/0

 no tcp burstrate

 ip icmp unreachable

 ip icmp echo-reply

 no ip address dhcp

 ip address 10.76.47.5/22

 ipv6 icmpv6 unreachable

 ipv6 icmpv6 echo-reply

 no ipv6 address autoconfig

 no ipv6 address dhcp

!

interface TenGigabitEthernet 2/0/1

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/2

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/3

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/4

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/5

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/6

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/7

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/8

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/9

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/10

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/11

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/12

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/13

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/14

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/15

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/16

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/17

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/18

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/19

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/20

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/21

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/22

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/23

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/24

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/25

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/26

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/27

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/28

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/29

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/30

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/31

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/32

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/33

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/34

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/35

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/36

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/37

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/38

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/39

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/40

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/41

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/42

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/43

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/44

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/45

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/46

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/47

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/48

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface FortyGigabitEthernet 2/0/49

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface FortyGigabitEthernet 2/0/50

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface FortyGigabitEthernet 2/0/51

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface FortyGigabitEthernet 2/0/52

 fabric isl enable

 fabric trunk enable

 no shutdown

!

 

 

 

 

sw0# show running-config

diag post rbridge-id 2

 enable

!

no fsb enable

dpod 2/0/1

!

dpod 2/0/2

!

dpod 2/0/3

!

dpod 2/0/4

!

dpod 2/0/5

!

dpod 2/0/6

!

dpod 2/0/7

!

dpod 2/0/8

!

dpod 2/0/9

!

dpod 2/0/10

!

dpod 2/0/11

!

dpod 2/0/12

!

dpod 2/0/13

!

dpod 2/0/14

!

dpod 2/0/15

!

dpod 2/0/16

!

dpod 2/0/17

!

dpod 2/0/18

!

dpod 2/0/19

!

dpod 2/0/20

!

dpod 2/0/21

!

dpod 2/0/22

!

dpod 2/0/23

!

dpod 2/0/24

!

dpod 2/0/25

!

dpod 2/0/26

!

dpod 2/0/27

!

dpod 2/0/28

!

dpod 2/0/29

!

dpod 2/0/30

!

dpod 2/0/31

!

dpod 2/0/32

!

dpod 2/0/33

!

dpod 2/0/34

!

dpod 2/0/35

!

dpod 2/0/36

!

dpod 2/0/37

!

dpod 2/0/38

!

dpod 2/0/39

!

dpod 2/0/40

!

dpod 2/0/41

!

dpod 2/0/42

!

dpod 2/0/43

!

dpod 2/0/44

!

dpod 2/0/45

!

dpod 2/0/46

!

dpod 2/0/47

!

dpod 2/0/48

!

dpod 2/0/49

!

dpod 2/0/50

!

dpod 2/0/51

!

dpod 2/0/52

!

logging raslog console INFO

logging auditlog class SECURITY

logging auditlog class CONFIGURATION

logging auditlog class FIRMWARE

logging syslog-facility local LOG_LOCAL7

logging syslog-client localip MM_IP

switch-attributes 2

 chassis-name VDX6740

 host-name sw0

!

no support autoupload enable

support ffdc

snmp-server contact "Field Support."

snmp-server location "End User Premise."

snmp-server sys-descr "Brocade VDX Switch."

snmp-server community ConvergedNetwork

snmp-server community OrigEquipMfr rw

snmp-server community "Secret C0de" rw

snmp-server community common

snmp-server community private rw

snmp-server community public

snmp-server user snmpadmin1 groupname snmpadmin

snmp-server user snmpadmin2 groupname snmpadmin

snmp-server user snmpadmin3 groupname snmpadmin

snmp-server user snmpuser1

snmp-server user snmpuser2

snmp-server user snmpuser3

line vty

 exec-timeout 10

!

zoning enabled-configuration cfg-name ""

zoning enabled-configuration default-zone-access allaccess

zoning enabled-configuration cfg-action cfg-save

role name admin desc Administrator

role name user desc User

aaa authentication login local

aaa accounting exec default start-stop none

aaa accounting commands default start-stop none

service password-encryption

username admin password "BwrsDbB+tABWGWpINOVKoQ==\n" encryption-level 7 role admin desc Administrator

username user password "BwrsDbB+tABWGWpINOVKoQ==\n" encryption-level 7 role user desc User

cee-map default

 precedence 1

 priority-group-table 1 weight 40 pfc on

 priority-group-table 15.0 pfc off

 priority-group-table 15.1 pfc off

 priority-group-table 15.2 pfc off

 priority-group-table 15.3 pfc off

 priority-group-table 15.4 pfc off

 priority-group-table 15.5 pfc off

 priority-group-table 15.6 pfc off

 priority-group-table 15.7 pfc off

 priority-group-table 2 weight 60 pfc off

 priority-table 2 2 2 1 2 2 2 15.0

 remap fabric-priority priority 0

 remap lossless-priority priority 0

!

fcoe

 fabric-map default

  vlan 1002

  priority 3

  virtual-fabric 128

  fcmap 0E:FC:00

  max-enodes 0

  enodes-config local

  advertisement interval 8000

  keep-alive timeout

 !

 map default

  fabric-map default

  cee-map default

 !

!

interface Vlan 1

!

fabric route mcast rbridge-id 2

!

protocol lldp

 advertise dcbx-fcoe-app-tlv

 advertise dcbx-fcoe-logical-link-tlv

 advertise dcbx-tlv

 system-description Brocade-VDX-VCS 100

!

vlan dot1q tag native

port-profile UpgradedVlanProfile

 vlan-profile

  switchport

  switchport mode trunk

  switchport trunk allowed vlan all

 !

!

port-profile default

 vlan-profile

  switchport

  switchport mode trunk

  switchport trunk native-vlan 1

 !

!

port-profile-domain default

 port-profile UpgradedVlanProfile

!

class-map cee

!

class-map default

!

rbridge-id 2

 ip route 0.0.0.0/0 10.76.47.1

 switch-attributes chassis-name VDX6740

 switch-attributes host-name sw0

 system-monitor fan threshold marginal-threshold 1 down-threshold 2

 system-monitor fan alert state removed action raslog

 system-monitor power threshold marginal-threshold 1 down-threshold 2

 system-monitor power alert state removed action raslog

 system-monitor temp threshold marginal-threshold 1 down-threshold 2

 system-monitor cid-card threshold marginal-threshold 1 down-threshold 2

 system-monitor cid-card alert state none action none

 system-monitor sfp alert state none action none

 system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0

 system-monitor MM threshold marginal-threshold 1 down-threshold 0

 system-monitor LineCard threshold marginal-threshold 1 down-threshold 2

 system-monitor LineCard alert state none action none

 system-monitor SFM threshold marginal-threshold 1 down-threshold 2

 no protocol vrrp

 no protocol vrrp-extended

 fcoe

  fabric-map default

   fcoe-enodes 0

  !

 !

!

interface Management 2/0

 no tcp burstrate

 ip icmp unreachable

 ip icmp echo-reply

 no ip address dhcp

 ip address 10.76.47.5/22

 ipv6 icmpv6 unreachable

 ipv6 icmpv6 echo-reply

 no ipv6 address autoconfig

 no ipv6 address dhcp

!

interface TenGigabitEthernet 2/0/1

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/2

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/3

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/4

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/5

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/6

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/7

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/8

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/9

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/10

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/11

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/12

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/13

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/14

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/15

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/16

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/17

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/18

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/19

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/20

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/21

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/22

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/23

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/24

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/25

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/26

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/27

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/28

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/29

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/30

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/31

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/32

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/33

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/34

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/35

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/36

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/37

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/38

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/39

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/40

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/41

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/42

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/43

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/44

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/45

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/46

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/47

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface TenGigabitEthernet 2/0/48

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface FortyGigabitEthernet 2/0/49

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface FortyGigabitEthernet 2/0/50

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface FortyGigabitEthernet 2/0/51

 fabric isl enable

 fabric trunk enable

 no shutdown

!

interface FortyGigabitEthernet 2/0/52

 fabric isl enable

 fabric trunk enable

 no shutdown

!

 

 

 

 

sw0# show sfp

Linecard Port    Type    Breakout Speed

-------  ------- ------- -------  -------

0        49      QSFP    1x40G    40G

0        50      QSFP    1x40G    40G

0        51      QSFP    1x40G    40G

0        52      QSFP    1x40G    40G

0        1       SFP     n/a      10G

0        2       SFP     n/a      10G

0        3       SFP     n/a      10G

0        4       SFP     n/a      10G

0        5       SFP     n/a      10G

0        6       SFP     n/a      10G

0        7       SFP     n/a      10G

0        8       SFP     n/a      10G

0        9       SFP     n/a      10G

0        10      SFP     n/a      10G

0        11      SFP     n/a      10G

0        12      SFP     n/a      10G

0        13      SFP     n/a      10G

0        14      SFP     n/a      10G

0        15      SFP     n/a      10G

0        16      SFP     n/a      10G

0        17      SFP     n/a      10G

0        18      SFP     n/a      10G

0        19      SFP     n/a      10G

0        20      SFP     n/a      10G

0        21      SFP     n/a      10G

0        22      SFP     n/a      10G

0        23      SFP     n/a      10G

0        24      SFP     n/a      10G

0        25      SFP     n/a      10G

0        26      SFP     n/a      10G

0        27      SFP     n/a      10G

0        28      SFP     n/a      10G

0        29      SFP     n/a      10G

0        30      SFP     n/a      10G

0        31      SFP     n/a      10G

0        32      SFP     n/a      10G

0        33      SFP     n/a      10G

0        34      SFP     n/a      10G

0        35      SFP     n/a      10G

0        36      SFP     n/a      10G

0        37      SFP     n/a      10G

0        38      SFP     n/a      10G

0        39      SFP     n/a      10G

0        40      SFP     n/a      10G

0        41      SFP     n/a      10G

0        42      SFP     n/a      10G

0        43      SFP     n/a      10G

0        44      SFP     n/a      10G

0        45      SFP     n/a      10G

0        46      SFP     n/a      10G

0        47      SFP     n/a      10G

0        48      SFP     n/a      10G

 

 

 

 

sw0# show startup-db

no fsb enable

no support autoupload enable

no support ffdc

no service password-encryption

no vlan dot1q tag native

 

 

 

 

sw0# show system

Stack MAC                     : 50:eb:1a:76:c9:28

 

  -- UNIT 0 --

Unit Name                     : sw0

Switch Status                 : Online

Hardware Rev                  : 131.7

TengigabitEthernet Port(s)    : 48

FortyGigabitEthernet Port(s)  : 4

Up Time                       : up 0:53

Current Time                  : 13:23:54 GMT

NOS Version                   : 4.1.3b

Jumbo Capable                 : yes

Burned In MAC                 : 50:EB:1A:76:C9:29

Management IP                 : 10.76.47.5

Management Port Status        : UP

 

  -- Power Supplies --

PS1 is OK

PS2 is OK

 

  -- Fan Status --

Fan 1 is Ok, speed is 2887 RPM

Fan 2 is Ok, speed is 2863 RPM

 

 

 

 

sw0# show udld

UDLD Global Information

  Admin State:       No UDLD Protocol

  UDLD hello time:   500 milliseconds

  UDLD timeout:      2500 milliseconds

 

 

 

 

sw0# show users

**USER SESSIONS**

RBridge

ID      Username                                 Role                                     Host IP                                        Device  Time Logged In 

2       admin                                    admin                                    127.0.0.1                                      Cli     2023-11-08 13:17:44

**LOCKED USERS**

RBridge

ID      Username

no locked users

 

 

 

 

sw0# show vcs

Config Mode    : Distributed

VCS Mode       : Logical Chassis

VCS ID         : 100

VCS GUID       : 00000000000000000000000000000000

Total Number of Nodes           : 1

Rbridge-Id       WWN                            Management IP   VCS Status       Fabric Status        HostName

--------------------------------------------------------------------------------------------------------------

2               >10:00:50:EB:1A:76:C9:28*       10.76.47.5      Online           Online               sw0

Specifications

Functional Condition:

F3 - Key Functions Working

Cosmetic Condition:

C4 - Used Good

Data Sanitization:

S3 - Data Clear


Mpn
N/A

Function Tests

Physical_Inspection
Passed
Powers_On
Passed
Functions
Passed

Shipping


Tracking information is automatically uploaded to ebay once your order ships.
We ship orders within the contiguous US with FedEx or USPS at our discretion. We use eBay's shipping calculator for all shipping rates.
PO Box, HI, AK, APO/FPO/DPO, and PR orders must be shipped via USPS. Please contact us or request an adjusted invoice before checking out.

Local Pickup
If you have purchased an item and prefer to pick it up, please select “Local Pickup” from the shipping options during checkout. Then please contact us to arrange pickup.
Payment must be made through ebay prior to pickup.

Combined Shipping
We can typically provide a 30% shipping discount for multiple purchases that will fit in the same box.
For combined shipping, please click 'Request Total' or send us a message before checking out.
We can then adjust your invoice for combined shipping.

Expedited Shipping
In order to guarantee the rates and transit times shown, we must receive your order with its payment cleared by 12:00 PM EST during business days.
Orders placed after 12:00 PM EST will be shipped on the next business day.
Orders placed on weekends or holidays will be shipped the next business day.
Please plan your orders accordingly.

Returns


We strive to be a 5 star seller and hope that you are happy with your purchase.
If there is a problem with your order, please contact us through eBay messages or by phone before leaving feedback.

For items that are tested and working properly:
Our return window for working items listed as "New" or "Used" is 30 days.
If the item is no longer wanted or does not fit, the buyer is responsible for return shipping.
If the item is not working as described, we will work with you on the issue, please contact us to resolve.