1200℃ Pre-vacuum Atmosphere Furnace Inert Gas Nitrogen Argon Atmosphere Furnace
This furnace is pre-vacuumed to ensure that the oxygen content in the furnace is minimized, and then nitrogen, argon or nitrogen-hydrogen is introduced to obtain the desired heating treatment under the protection of the atmosphere. Due to its excellent atmosphere and compactness, it has been widely used in material laboratories or small batch production of semiconductors, silicon nitride and other products.

Features:
Product use: Box-type atmosphere furnace is ideal equipment for atmosphere protection sintering and atmosphere reduction in universities, scientific research institutes, and industrial and mining enterprises. It has the characteristics of a uniform temperature field, fast heating and cooling speed, energy saving, and can be introduced into a variety of gases.
Temperature control safety: The electric furnace adopts integrated circuit, module control, double-loop protection (bias temperature protection, ultra-high temperature protection, breakage protection, overcurrent protection, overvoltage protection, and other protection functions) to make the electric furnace work stably, reliably, and safely.
Heating rate: The maximum heating rate is 30°C/min, and 20°C/min is recommended.
Furnace material: The internationally advanced lightweight alumina ceramic fiber is used, which has excellent thermal insulation effect, lightweight and high-temperature resistance, rapid cooling and rapid heating resistance, no cracks, no crystallization, no slag loss, and no need to worry about contamination of the fired products. The energy-saving effect is 60%-80% of the old-fashioned electric furnace.
Furnace design: The furnace adopts a stepped assembly structure, which integrates the laws of mechanics, which effectively ensures that the furnace is uniformly stressed during the heating process, ensures that the heat energy is not easily lost, and prolongs the service life of the furnace.
Gases available: all inert gases, mixed gases, nitrogen, carbon dioxide, water vapor, argon, oxygen
Gas control: 1 or more air inlets can be set at the air inlet, each air inlet is equipped with a needle valve, which is connected to a vacuum gauge. The outlet end is connected with one outlet hole, and all holes are equipped with a needle valve. Equipped with a vacuum pump.
Sealing method: The furnace door adopts the overall plane grinding and milling, and the silicone strip is embedded and sealed, which has a strong sealing performance, and the furnace door is easy to open and close.

Accessories:
Standard accessories: 1 vacuum pump, 1 crucible tongs, 1 pair of special high-temperature gloves. 1 copy of the instruction manual.
Optional accessories: touch screen control, paperless recorder, remote communication control system.

Chamber size

150x150X150mm (Width * Height * Depth) 

Max. temperature

1200 C (<2hour)

1400 C (<2hour)

1700 C (<2hour)

Working temperature

1100 C

1300 C

1600 C

Temperature controlling

PID automatic control via SCR (Silicon Controlled Rectifier) power control with phase angle fired, current limiting resistor.

51 programmable segments for precise control of heating rate, cooling rate and dwell time.

Built in PID Auto-Tune function with overheating & broken thermocouple broken protection.

Over temperature protection and alarm allows for operation without attendant.

Temperature accuracy

±1C

Temperature Uniformity

±5C over 120mm

±3C over 80mm

Heating rate

0-20C /min

Vacuum

10Pa

Atmosphere

Inert gas like nitrogen and argon

Thermocouple

K type

 S type

 B type

Heating element

Heating wire

SiC heating element

MoSi2 Heating element

Furnace Chamber

2 layers of ceramic fiber insulation

3 layers of ceramic fiber insulation

3 layers of ceramic fiber insulation

1st: 1430°C ceramic fiber board

1st: 1700°C ceramic fiber board

1st : 1800°C ceramic fiber board

2nd: 1260°C ceramic fiber board

2nd:1430°C ceramic fiber board

2nd: 1600°C ceramic fiber board

 

3rd: 1260°C ceramic fiber board

3rd: 1260°C ceramic fiber board

Furnace structure

Double layer steel casing with dual cooling fan, surface temperature below 60C

Furnace door

Front-side open

Power cutting off when furnace door open

Working voltage

110V or 220V or 380V, 50HZ or 60HZ

Rated power

4KW

Stander chamber size (mm)

100x100x100      120x120x130      150x150x150      150x150x200

200x200x200      200x200x300     250x250x300      300x300x300

300x300x400      350x350x500     400x400x400      450x450x450

500x500x500      600x600x600     800x800x800      900x900x900 

 

Note: the chamber size can be customized

  • Payment should be completed within 4 (Four) days of auction closing. Or unpaid dispute will be filed for closing auction.
  • We will leave a positive feedback immediately after payment is received. We appreciate a positive feedback as much as you do. If for some reason there is any issue with the purchase, please contact us prior to leaving feedback, we will be glad to work together and provide a satisfying solution.
  • We only ship the item to the eBay Verified address that is sent to us at the time of checkout, most shipment will be shipped within 1-5 business day. Please verify the correct shipping address in your eBay account before making your payment. Shipping time during holidays may take longer than normal. 
  • Any brokerage, customs, and duty fees associated with international shipments are the customer's responsibility and are not included in our shipping charges. 
  • If you are located outside of the continental 48 United States, please email us in advance to see if the specific item ships to your location. These orders are generally shipped within 1-5 days after payment is received. 
  • Please be patient as they are often subject to additional inspection upon delivery.
  • All of our items are backed with a 30-day return policy. We ensure all our items are new and in excellent condition prior to shipping. In case you receive the item that is not to the standards above, please contact us via e-Bay messages. All returns must be in new original condition as received and should be shipped with delivery confirmation
  • Please note that all returns must be pre-approved by us. Unauthorized returns will not be accepted. If you need to return, please check twice to confirm the item not work and contact our customer service representative, let us know the detailed problem and send us some pictures for confirmation.
  • We ONLY accept returns with original package. Please make sure that item has NO man-made sabotage. Used items will not be accepted for return.
  • We are a comprehensive company specializing in the research and development, production and sales of lab related equipment. Company tenet: Respect reputation and contract, provide high-quality and low-cost equipment for serve scientific research.
  • We believe that it is our vision and mission to provide innovative products with best service and competitive price to satisfy you. Our goal is to make sure that you can find exactly what you are looking for and make it easy for you to place your orders.
  • Email Customer Support:
  • 9:00am-2:00am PST Sunday-Friday
  • All emails will be responded to within 12-24 hours