Lab Use Digital Heated Object Stage Digital Preheated Board For Microscopes

Notice:

It will take a while for the board to heat due to its low power. The time it takes is between 5-10 Min. Be careful when it is heating and keep it clean after use.

The display number is of Celsius Degrees

 

Description

The working panel of the microscope warming table is made of aluminum alloy, which has good wear resistance and corrosion resistance for long-term use. The instrument can adjust the temperature and has an LED display for your convenience.

 

 

Specification  

Material: Aluminum Alloy

Working Power Supply: 110V/ 60HZ

Heating Power Supply: 10V±10% 50HZ

Heating Power: 5W 

Working Size: 55×95mm/2.17*3.74in

Working Surface Temperature Range: Room Temperature ~50℃ (Adjustable)

Working Surface Temperature Difference: ≤0.5℃

Working Surface Size: 9.5 × 5.5 × 0.7cm/3.74*2.17*0.276in

Control Box Dimensions: 18 × 17× 11cm/7.09*6.69*4.33in

Light Hole (mm): Ф11

Maximum Filament Power: 32 Watts

Overall Machine Weight: 1.13kg/2.49lbs

 

 Package Included

1* Microscope Warm Stage

 

 

Details

LED Digital Display: The working surface temperature of the microscope warm stage is displayed by an LED digital display with an accurate reading.

Aluminum Alloy Heater: The heater is made of specially formed aluminum alloy, so the temperature rise is even and flat.

 

Application

The microscope warm stage is widely used for sample baking, drying and other temperature tests, it is a necessary tool in biological genetics, medicine and health, environmental protection, biochemical laboratories, analytical laboratories, education and scientific research.

 

Key Features

High Durability: The work surface plate of the microscope warm stage is made of aluminum alloy which has good wear and corrosion resistance and can be used for a long time.

Fast heat-up: The heater of the heating table is made of specially formed aluminum alloy, so the temperature rise is fast and even.

Easy Operation: It is easy to operate the microscope warm stage, you just need to set the temperature and the internal function parameters and then turn on the start button.

Adjustable Temperature: You can press SET to set the temperature, if the lower row of digital data flashing (the upper row of normal temperature measurement), it means that the instrument enters the temperature setting state, you can set the temperature (with a maximum temperature of 50°C) according to your own needs.

Moderate Size: With a small size , the microscope warm stage will not take too much space, you can easily move it anywhere you want, facilitating your daily use.

 

Use and Maintenance

1. Please put the working surface before use Wipe clean, no water droplets, dirt, dirt, and other foreign matters remain on the top and bottom.

2. Place glass slides, sample bottles or other utensils.

3. Connect the power supply, close the power switch, place the selector switch at the setting end, adjust the temperature to the temperature you need, and then place the selector switch at the measurement end. At this time, the actual temperature of the thermostatic plate is displayed. When the temperature needs to be higher than the actual temperature, the indicator light is on, indicating that the heater has started to work, and the indicator light is on to indicate that the heating has stopped and is in a constant temperature state. At this time, when the temperature fluctuates, the indicator light automatically switches (no operation is required) to make the temperature of the constant temperature board temperature. keep constant.

4. When the thermostatic plate is in working condition, a special person should take care of it.

5. When the work is finished, turn off the power switch and cut off the power supply.

6. After the working surface is cooled, follow the requirements of (1).

 

Temperature Control Instrument Operation Manual

1. Set temperature: Press the SET key to set the temperature, press the SET key, the lower row of digital tube data flashes (the upper row of normal temperature measurement), indicating that the instrument enters the temperature setting state, press the △ key to increasing the setting value, press the ▽ key to set The fixed value decreases. If you continue to press the increase key or the decrease key, the setting value will change quickly. Press the SET key again and the instrument will return to the normal working state. The temperature setting is complete.

2. Correction of sensor error: The displayed value can be corrected when it is confirmed that the value displayed by the meter is not the correct measured value. Press the SET key for 3 seconds to enter the inner menu of the instrument. After selecting the parameter SC, cooperate with the △ or ▽ key to modify this parameter. The range of sensor error correction is +50 to -50. After the correction is completed, press the SET key for 3 seconds to exit. The correction value of the meter is 0 when it leaves the factory, and it is necessary to prevent the correct display of the meter from being corrected to incorrect when using it.

3. Start auto-tuning: This product can adapt to most control systems. Only when the control effect is particularly unsatisfactory can auto-tuning be started. Press the SET key for 3 seconds to enter the inner menu of the instrument. After selecting the parameter At, cooperate with the △ or ▽ key to start the auto-tuning Tuning. At this time, the At indicator starts to flash and the instrument enters the auto-tuning parameter working state. The instrument control heating system fluctuates twice at the set point. When the At indicator is off, the auto-tuning ends, and the new PID parameters are locked in the chip.

 

Notes

Please allow the slight color difference caused by the shooting light and 1-3cm error due to manual measurement, and make sure you do not mind before ordering.