|
|
|
|
|
|
This Item Has A Current Calibration!
|
|
|
Fluke 810 Mechanical Machine Vibration Tester
Quickly identify and prioritize mechanical problems, putting the expertise of a vibration analyst in your hands.
Includes Carrying Case & Accessories As Listed Above!
Working Condition: Excellent Condition: Refurbished Calibrated: Yes Warranty: 1 YEAR WARRANTY
Fluke 810 Vibration Tester For years, technicians struggled to decipher machine vibration—an early sign of mechanical trouble—using a dowel, a screwdriver, or a stethoscope. Their only alternative was to turn to expensive consultants, complex vibration analysis tools, or full Predictive Maintenance programs that take time, money, and manpower to implement. Many maintenance teams simply need fast and actionable answers.
The new Fluke 810 is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now...
- Analyzes common equipment
- like motors, fans and blowers, belts and chain drives, gearboxes, pumps, compressors and spindles.
- Detects the root causes and locations of mechanical failures
- bearing problems, misalignment, unbalance and looseness, the most common mechanical problems facilities face.
- Gives an immediate fault severity assessment
- and repair recommendations
- Helps technicians quickly understand machine health
- and set repair priorities so they can work more efficiently and effectively.
- Helps managers control unplanned downtime
- by anticipating problems early, eliminating recurring problems, and manage resources. It also bridges the skills gap by capturing decades of mechanical experience in one tool.
Troubleshooting machines is now a simple 3-step process Fluke 810’s unique design and intuitive user interface make testing machine vibration much easier than it has ever been.
- Setup: Technicians enter basic machine information like RPM and horsepower. The on-board Info feature gives field tips for setting up and taking measurements like a pro.
- Measure: The tester can be used to quickly troubleshoot problems on the spot, or monitor machine conditions.
- Diagnose: With a press of a button, the Fluke 810 identifies the root cause, its location and the problem’s severity.
Features:
- On-board identification and location of the most common mechanical faults (bearings, misalignment, unbalance, looseness) focus maintenance efforts on root cause, reducing unplanned downtime
- Fault severity scale with four severity levels helps you prioritize maintenance work
- Repair recommendations advise technicians on corrective action
- On-board context sensitive help provides real-time tips and guidance to new users
- 2 GB expandable on-board memory provides enough space for your machinery’s data
- Self-test function ensures optimal performance and more time on the job
- Laser tachometer for accurate machine running speed promotes confident diagnoses
- Tri-axial accelerometer reduces measurement time by 2/3 over single axis accelerometers
- Viewer PC Software expands data storage and tracking capacity
Can Be Used To:
- Troubleshoot problem equipment and understand the root cause of failure
- Survey equipment before and after planned maintenance and confirm the repair
- Commission new equipment and ensure proper installation
- Provide quantifiable proof of equipment condition and drive investment in repair or replacement
- Prioritize and plan repair activities and operate more efficiently
- Anticipate equipment failures before they happen and take control of spare parts inventories
- Train new or less-experienced technicians and build confidence and skill across the team
Specifications:
Diagnostic Specifications
|
Standard faults
|
Unbalance, looseness, misalignment, and bearing failures
|
Analysis for
|
Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles
|
Machine rotational speed range
|
200 rpm to 12000 rpm
|
Diagnosis details
|
Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra
|
Electrical Specifications
|
Ranging
|
Automatic
|
A/D Converter
|
4 Channel, 24 Bit
|
Sampling
|
51.2 Hz
|
Digital signal processing functions
|
Atomatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging
|
Sampling rate
|
2.5 kHz to 50 kHz
|
Dynamic range
|
128 dB
|
Signal to noise ratio
|
100 dB
|
FFT resolution
|
800 lines
|
Spectral Windows
|
Hanning
|
Frequency units
|
Hz, orders, cpm
|
Amplitude units
|
in/sec, mm/sec, Vdb (US), VdB (Europe)
|
Non-volatile Memory
|
SD micro memory card, 2 GB interal, + user accessible slot for additional storage
|
General Specifications
|
Dimensions (HxDxW)
|
18.56 cm x 7.00 cm x 26.82 cm (7.30 in x 2.76 in x 10.52 in)
|
Weight (With battery)
|
1.9 kg (4.2 lb)
|
Display
|
1/4 VGA, 320 x 240 color (5.7 inch diagonal) TFT LCD with LED backlight
|
Input/Output Connections
|
Triaxial sensor connection 4 pin M12 connector Single axis sensor connection BNC Connector Tachometer Connection: Mini din 6 Pin Connector PC Connection Mini 'B' USB (2.0) Connector
|
Battery
|
Battery type Lithium-ion, 14.8 V, 2.55 Ah Battery charging time Three hours Battery discharge tim eEight hours (Under normal conditions)
|
AC Adapter
|
Input voltage 100 Vac to 240 Vac Input frequency 50/60 Hz
|
Operating system
|
WinCE 6.0 Core
|
Language Support
|
English, French, German, Italian, Japanese, Portugese, Simplified Chinese, Spanish
|
Environmental Specifications
|
Operating Temperature
|
0°C to 50 °C (32 °F to 122 °F)
|
Storage Temperature
|
-20°C to 60 °C (-4 °F to 140°F)
|
Operating humidity
|
10% to 95% RH (non-condesing)
|
Agency approvals
|
CHINA RoHS, CSA, CE, C TICK, WEEE
|
Electromagnetic compatibility
|
EN 61326-1:2006, EN 61010:1:2001 2nd ed.
|
Sensor Specifications
|
Sensor type
|
Accelerometer
|
Sensitivity
|
100 mG/g (± 5 %, 25 °C)
|
Acceleration range
|
80 g peak
|
Amplitude nonlinearity
|
1%
|
Frequency response
|
Z: 2 - 7,000Hz ± 3dB X, Y: 2 - 5,000 Hz ± 3dB
|
Power requirement (IEPE)
|
18 V dc to 30 V dc, 2 mA to 10 mA
|
Bias output voltage
|
12 V dc
|
Grounding
|
Case grounded
|
Sensing element design
|
PZT ceramic / shear
|
Case material
|
316L stainless steel
|
Mounting
|
10-32 captive socket head screw, 2-pople rare earth magnet (48 lb pull strength)
|
Output connector
|
4-Pin, M12
|
Mating connector
|
M12 - F4D
|
Non-volatile memory
|
TEDS 1451.4 compatible
|
Vibration limit
|
500 g peak
|
Shock limit
|
5000 g peak
|
Electromagnetic sensitivity, equivalent g
|
100 µg/gauss
|
Sealing
|
Hermetic
|
Temperature range
|
-50 °C to 120 °C (-58 °F to 248 °F) ± 7 %
|
Tachometer Specifications
|
Dimensions (DxW)
|
2.86 cm x 12.19 cm (1.125 in x 4.80 in)
|
Weight
|
96 g (3.4 oz) with cable
|
Power
|
Powered by 810 vibration tester
|
Detection
|
Laser Diode Class 2
|
Range
|
6.0 to 99,999 rpm
|
Accuracy
|
6.0 to 5999.9 rpm: ± 0.01 % and ± 1 digit 5999.9 to 99999 rpm: ± 0.05 % and ± 1 digit
|
Resolution
|
0.1 rpm
|
Effective range
|
1 cm to 100 cm (0.4 in to 39.27 in)
|
Response time
|
1 second (> 60 rpm)
|
Controls
|
Measure on/off transparent button
|
Interface
|
6 pin Mini din
|
Cable length
|
50 cm (19.586 in)
|
For full Fluke 810 product specifications, please click here: Fluke 810
|
|
|
Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.
|
|
|
|
|
|
|
|
|
|