The Retsch Camsizer X2 was build 2016 and 2017 delivered and installed .Beside the qualification it was not used only 2 measurements were done in total !


In the name of science a great opportunity to get this over hundred-thousand Dollar set with a great discount so your Laboratory can generate fast and reliable results under the modern state of art in Particle inspection.


The design of the CAMSIZER X2 is based on the well-proven optical particle measurement system  this Camsizer is optimized for finer samples (from 0.8 µm to 8 mm) and comes with various modules to cover the complete section of particle engineering .


Not only the improved optical resolution but also new options for material feeding allow for an extended application range.


Fine particles tend to agglomerate which makes it difficult to record the properties of a single particle. Therefore, it is important to have various possibilities of feeding the sample to the analysis area to be able to find for each material the optimum between the desired dispersion of the agglomerates and the undesired destruction of the individual particle.


The CAMSIZER X2 offers the flexible X-Change system: from the X-Fall module (free fall mode), which is the most gentle method for the material, to the X-Jet module with adjustable pressure and variable nozzle geometry and, additionally, the X-Flow module in which particles are dispersed in liquids, optionally by an ultrasonic probe



Basic Camsizer X2 : Double cam X module comes with the Elite Desk PC core i7 &  windows 10 with special Retsch network-card and preinstalled Software which is as well separate in form of the installation set incl   (CD software bundle incl windows.)


 

the Digital image processing with patented two-camera-system  "DIA "(acc. to ISO 13322-2)

can measure to the Standard Measuring-range with help of those X features  :

-0.8 µm to 8 mm

-10 µm to 8 mm (gravity dispersion)

-0.8 µm to 5 mm (air pressure dispersion)

-0.8 µm to 1 mm (wet dispersion)


With the newest developed optical system with ultra-strong LEDs for highest resolution and excellent depth of sharpness the system has fantastic reliability for detection of smallest amounts of "undersize" and "oversize" this is absolute great for Simultaneous analysis of particle size, shape, number, density and transparency



Also due to the Very short measurement time of 1 - 3 minutes allot of time can be invest in other lab activity and also is a Time saver in  urgent situations compare to classic systems. The set is high Modular and allows the Retsch Camsizer X2 system  an easy swap for dry and wet dispersion in a short period as well called  "X-Change"


  - Measurement results are 100% compatible to sieve analysis if required and takes

    Less time- and labor-intensive than sieve analysis  

 -  Intuitive software  21 CFR Part 211 compatible & comes in Several language versions

    (German, English and other languages)

  - Detailed particle size analysis - results are saved in more than 1,000 size classes

    


further benefits are :

    No-contact, non-destructive measurement

    Simple handling prevents operating errors

    Calibration in seconds

    Password protected instrument settings according GMP

    Automatic measuring procedure

    Robust design, insensitive to dust and vibrations

    Self-cleaning, wear-free, maintenance-free

    Time savings compare to Classic procedures



All in all a great R&D or Quality control tool to Test as well abrasives

> (medium-size and small grit)

 activated carbon, cement, chemicals, construction materials, detergents and enzymes, foodstuffs

>(pulverized and granulated), glass beads, metal and ore powders, pharmaceutical powders / granules / fine pellets, plastic fibers, plastic powders, salts, sand, sugar, wood fibers, etc.


Camsizer X2 set is delivered with following features:


X Flow part no 150.0026 :CAMSIZER X2 part no 151.0001  also offers the option to analyze particles in liquids with the X-Flow module. The suspension flows in a closed circle through a glass cell where the cameras record the particle images. The integrated ultrasonic unit further aids in the dispersion process.


X Fall part no 150.0022: The X-Fall module is used for non-destructive measurement of sensitive samples in free fall to minimize particle breakage. The sample can be recovered after the analysis. (nilifisk set is incl.)


X Jet part no 150.0021 : The X-Jet module disperses the sample via a Venturi nozzle and is suitable for the effective analysis of powders. The actual measurement of the particles takes place in the air stream. Dispersion pressure may be set between 0 kPa and 460 kPa. This ensures optimum analysis conditions for all sample types.


 With spare parts and some consumables like pipette and vials and manual cleaning pump / also separate Cell for the the X flow module


Digital image processing with patented two-camera-system works according to ISO 13322-2


 

The only con on this amazing set known is that the small backup Battery on the motherboard need to be exchanged .

All in all perfect a complete set ready to rock your Lab ! as seen on pictures

 (HP mouse incl was not pictured)


quotation marks : Retsch homepage & manuals / Mircrotrac Homepage  & its related promo pages as AZOM