ABS case: 58.7mm x 91.3mm x 17.1mm (excluding protrusions)
PCB: 54mm x 85.5mm x 11mm (without connectors, switches)
Measurement frequency: 10KHz -1.5GHz
RF output: 0dbm (±2dbm)
Measurement range: 70dB (50kHz-300MHz), 60dB (300M-900MHz), 40dB(0.9G-1.5GHz));
Port SWR: < 1.1
Display: 2.8 inch TFT (320 x240)
USB interface: USB type-C communication mode: CDC (serial)
Power: USB 5V 120mA, built-in 650mA-h battery, maximum charging current 300mA
Number of scanning points: 101 (fixed)
Display Tracking: 4, Marking: 4, Setting Save: 5
Frequency Tolerance:<2.5ppm
Frequency Stability:<0.5ppm
You can use a MicroSD card to save measurement data in SNP format or to save screenshots in BMP format. MicroSD card uses SPI mode and only supports smaller than 32GB and formatted with FAT or FAT32.
In addition, different from old version, the date and time of vna can be display, which is convenient for you to further record and save data.
1X Antenna Analyzer Host
2X 20cm SMA Male to Male RG174 RF Cable
2X SMA Female to Female Connector
1X SMA Simple Calibration Kit SHORT
1X SMA Simple Calibration kit OPEN
1X SMA Simple Calibration kit LOAD
1X USB Type-C Data Cable
1X USB-C to USB-C Line
1X Touch Paddle
1X 32GB Card
The default firmware main function is used for antenna performance measurement. The TX/RX method can measure the complete S11 and S21 parameters. If you need to obtain S12 and S22, you need to manually replace the transceiver port wiring
Compare with old version, it supports time domain analysis function (TDR), and more convenient to connect to mobile phones. Compatible with most Android mobile phones. Support Windows Computer Control.