Endo Sonic Activator Dental Endo Irrigator Handpiece+60 Flexible Tip Never Break
endodontic irrigator activator
 
Package List:
Main Unit 1 PC
Protective Barrier 100 PCS
Package list:
Needle Tips:
2/15  20 PC
4/25  20 PC
4/35 20 PC
 
1. Indications For user
The Easydo Activator system uses technology of sonic energy for root canal treatment. The driver work with the Hand device, motor and needle tip to provide power for tip oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic streaming can improve debridement and the disruption of the smear layer and biofilm.
The Activator helps the fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal, Connection of inter-root canal and root apex to ensure deep cleaning and sterilization of root canal. It is beneficial to complete the 3D filling of the root canal and ensures long-term success.
2. Notice
1) Remove the needle tip of EasyDO Activator. If your treatment process is
over, please leave it for medical recycling.
2) Please put exhaustively discharged battery into the recycling box.
3Do not submerge the unit in water.
4Do not autoclave the unit.
3. Precautions
1) The EasyDO Activator system is only used by dental professionals.
2) The EasyDO Activator system is comprised of the Hand device and Activator needle tips of various sizes. If the system functions are used correctly, the equipment can maintain a normal operation. It is strictly prohibited to use non-original components, which will damage the equipment and make it unable to work normally. The original components include the Easydo activator hand device, needle tip and protective cover.The Easy smile reference number of the hand device EASYDO Activator-M10821
The reference numbers of the EasyDO
Activator Needle tip
M10822-015 (Small)
M10822-025 (Medium)
M10822-035 (Large)
 
3The handle device provides three speeds sonic motor adjustment options
(High, Med, Low). The speed gears switch setting adjustment is ultimately
determined by the procedure to be performed, the cliniclan' experience can
efficiently complete the clinical task.
4) The handle device don’t require calibration for normal use.
5) All clinical treatment should be performed with Easydo activator
protective barrier sleeve that placed over the hand device.
6) In the course of treatment, we should use sterilized and individually
packed needle tip, otherwise it will cause root canal infection.
7) It is necessary to use EasyDO Activator system correctly according to
treatment specifications and operation manual to prevent injury to patients.
8) Improper using of the hand device may result in broken handle of the
equipment and damage of internal components.
9) The EasyDO Activator needle tips and protective sleeve are intended for
single-patient use only. Cross contamination may occur to the patient if
needle tips and protective barriers are re-used.
 
 
4. Warranty information of EasyDO activator
1TheEASYINSMILEcompanyprovidesuserswithqualityassurance withinoneyearfromthedateofpurchaseofthisproduct.In caseofany
failureduetothedefectof Handdevice materialorproductionprocessofthemainframe withinthisyear,the EASYINSMILE companywill provideequipmentrepairorreplacementproducts.
2Thewarrantydoesnotinclude consumablessuchasneedles, batteries,etc.
3Iftheequipmentisdamagedduetoimproperuseandmaintenance,
ormaintenancepersonnel repairorchange ofsparepartswithoutthe
authorizationofEASYINSMILE, thewarrantypolicyisinvalid.
4Underanycondition,neitherEASYINSMILE noritsaffiliatesare
responsibleforanyspecial,incidental,orconsequentialliability
resultingfromaviolationofthewarrantypolicy,contract,oranyother
legalpolicy.Such damagesincludebutarenotlimitedtolossof
investment,lossofprofits,losscausedbywronguseofproduct
functions,etc.;includingbutnotlimitedtothirdpartyclaimsand
increaseofservicecostcausedbyanyalternativeequipment,etc.
 
5Warrantylimitations
Contentnotcoveredbywarranty:
-Needle tip
-Handdevicebarrier sleeve
-Damagecausedbymisuse,abuse,neglectofpromptorchange of the
equipmentusage
-Normalwearandotherexternalscratches,includingscratches,wear,
cracks,discolorationorfade.
-Batteryreplacement
*Note:
Iftheproductisnotusedforalongtime(twoweeksorlonger),please
removethebattery.Italsomustberemovedduringtransport,for
example,duringdelivery
10) Properly dispose the Activator needles tip and hand device protective
barriers in accordance with the local laws and regulations and environmental
protection requirements.11) Dispose the battery after being used in accordance with the local laws
and regulations and environmental protection requirements, when battery is
exhausted.
12) The hand device must be repaired if necessary according to the direction
of the manufacturer.
13) Don’t insert needle tip into the hand device. If the equipment is not used
for a long time, placing the hand device into packing box is recommended.
14) Remove the battery when the hand device is not used for a long time.
15) The hand device can be kept at the temperature of 0 ~ 55 ,
relative humidity 0% ~ 75% RH and air pressure750-1060 HPA.
16) The hand device should be keep away from strong electromagnetic
interference, which may affect the performance and normal use of hand
device.
17) The hand device should be kept away from portable or mobile RF
communication devices, which may affect the performance of hand device .
18) The hand device could not be adjacent to or stored with other equipment.
In addition, it is necessary to check regularly whether the hand device can
work normally.
19)Properdisposalofthehand device isrequired whenthehand piece
isdeemedno-functional inaccordancewithlocallawsandregulations.
6.Product parameters
Name
EasyDO Activator
Model
EASYDO Activator-M1082
Function
Debridement / disinfection / root canal therapy
Use environment
Indoor environment; Temperature range: 0 ~ + 55 ; Relative
Humidity: 0% ~ 75% RH; Air Pressure: 750-1060 HPA
Power Supply
DC1.0v~1.5v
Battery
AA grade LR6, 1.5v mercury-free alkaline dry battery
Size
L 183mm * W 23mm * H43.1mmGross Weight
124g
7.Operation / Step
Preparation:
1)Preparetherootcanaltoproduceafullytaperedshape.
2)FillpupchamberwithNaOCI,EDTA,orfinalrinsesoulution.
3)Selecttheneedletipthatmanuallyfitslooselywithin2mmof the
workinglength.
4) Placethebarriersleeveover thecompletelengthofthehanddevice.
5)Connecttheneedletiptothehand device withthebarrier sleeve.The
activatorshouldsnaponfirmly,promotingasecureconnectionwiththe
handdevice.
6)PressON/OFF buttonfor 1 second,youcanseethebatterypower
status.Ifthepowerisenough,youcancontinuethetreatment.Ifthe
powerisnotenough,youneedtoreplacethebattery.
7)Placetheattachedneedle tip intothepreparedrootcanal.
8)DrepresstheON/OFFbutton toactvate.Switchdefaultstohighspeed
uponactivation. Depress the3-speedswitchtoselectmediumspeedor
lowspeed.
9)Useapumpingactiontomovethehanddevice inshort2~3mm
verticalstrokes.
10)Hydrodynamicallyagitatethemedicalsolutionforabout30-60
seconds.
11)Afterwashing,useasuctionpipetoremoveloosedebrisand
sundries fromtherootcanal.
12)Repeattheabovestepsforeachdifferentrootcanaltreatment.
*whentheclinicalprocedurehasbeencompleted,remove the
protectivebarrier sleeve,removetheneedle tip andstoreitin themedicalwasterecyclingbox. The needle tip andprotectivesleeve are
intendedforsingle-patientused only.
Otherinstructions:iftheEasyDOActiver handdevicehasbeenworking
for8minuteswithoutanyoperation,orthereisnooperationafterthe
equipment stopsworking,itwillenterthestateofself-protection
systemandpoweroFF. Ifyouneedittorestart ,pleasedepressthe
ON/OFFswitch.
8. Key points of Operation:
5.1POWER OF BATTERY STATUS
Depressthe" ON /OFF Switch"keyfor1secondtoobservethe"Power
Indicator"statusaroundthebuttonof thehanddevice.
1. Ifthe"PowerIndicator"iswhite,itmeanstheactivatorsystemisin
fullpowerstatus;
2. ifthe"PowerIndicator"isredandwhite,itmeansthesystemisin
halfpowerstatus;
3. ifthe"PowerIndicator"isred,itmeansthesystemisinpower
shortagestatus;4. Ifthe"PowerIndicator"isflashingred,itindicatesthatthesystemis
onthevergeofpowerfailure.
5. Please noteifthe"powerindicator"isflashingred,pleasereplacethe
battery.
 
 
PushAuction