  • Fluke 1524 Reference Thermometer (BC# 20718-L/T*)
  • DC Car Charger
  • AC Adapter/Charger
  • Power Cord
  • User Manual On CD-ROM
  • Carrying Case (G)



BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS!

Calibrated

This Item Has A Current Calibration!

Calibrated


Fluke 1524 Handheld Dual Channel Reference Thermometer

The 1524 Reference Thermometer from Fluke’s Hart Scientific division measures, graphs, and records PRTs, thermocouples, and thermistors

Includes Carrying Case & Accessories As Listed Above!

 
 

Working Condition: Excellent
Condition: Refurbished
Warranty: 1 YEAR WARRANTY

 

 Fluke 1524 Reference Thermometer

Finally, a reference thermometer as versatile as you are
The new 1524 Reference Thermometer from Fluke’s Hart Scientific division measures, graphs, and records PRTs, thermocouples, and thermistors. The new thermometer readouts deliver high accuracy, wide measurement range, logging, and trending, all in a handheld tool you can take anywhere.

The 1524 lets you handle field applications, laboratory measurements, and data logging with ease. And with the dual channel measurement capabilities of the model 1524, you can do twice the work in half the time.

Make accurate, consistent measurement...anywhere
You need accuracy for compliance, product yields, energy savings, and consistent results. The 1524 uses current reversal, a technique used in high-end instruments that eliminates thermal EMFs, for precision temperature measurements. Specifications are guaranteed from –10 °C to 60 °C ambient. Special precision resistors and a highly stable reference voltage source keep 1524 accuracy virtually insensitive to environmental temperature.

Like all Fluke handheld tools, the 1524 Reference Thermometer endures rigorous testing in temperature extremes and under harsh conditions of vibration, so you can take it with confidence anywhere you need to go.

Monitor trends in the lab or in the field
See trends graphically on the 1524 thermometer’s 128x64-backlit LCD display. You can change the graph’s resolution at the touch of a button. Now it is easy to see when the temperature is stable (without statistics or long delays) or to monitor processes over time to verify correct operation.

Hold readings on the display at the touch of a button, or document up to 25 readings and associated statistics for easy retrieval. Statistics include the average maximum and minimum values, and the standard deviation.

View them through the display or by uploading it to a PC via RS-232 conection and 9940 I/O TookKit software. To monitor and log more data over time, use a PC and optional LogWare II software

RS-232-to-USB adapters are available for those who prefer USB connectors. Battery power lasts at least 20 hours on three AA batteries, or use the dc power adapter for extended periods of measurement. Power saving features can be enabled or disabled for longer battery life or greater convenience.

INFO-CON connectors ensure correct temperature conversion
Inside the INFO-CON, a memory chip keeps calibration information for the attached probe. Simply plugging in the probe uploads the information to the readout. The connector transfers this information to the 1524 automatically, ensuring the correct temperature conversion for accurate, hassle-free measurements

Probes may be locked by password to specific channels and readouts for security or for system calibration traceability. Plug any thermocouple with mini-thermocouple jacks into an optional universal thermocouple adapter for convenient measurement. Each thermocouple adapter or standard connector supports reference junction compensation (RJC) with its own internal precision thermistor.



Features:

  • High accuracy
  • PRTs: up to ± 0.011 °C
  • Thermocouples: up to ± 0.24 °C
  • Precision thermistors: ± 0.002 °C


Specifications:

Input channels 2
Resolution Resolution PRTs and thermistors: 0.001°
thermocouples: 0.01°
Logging 25 readings with statistics15,000 time and date stamped
Sample interval (normal)
1 second (simultaneous measurement)
Typical sample interval (fast mode)* 0.3 seconds
Sensor types PRTs, RTDs, thermistors, and thermocouples
Thermocouple types
C, E, J, K, L, M, N, T, U, B, R, S
Statistics Maximum, minimum, average, standard deviation
Trending Scale: ± 10 °C (18 °F), ± 1 °C (1.8 °F), ± 0.1°C (0.18 °F), ± 0.01°C (0.018 °F), 10 minutes of real-time data
Power requirements 3 AA alkaline batteries, 12 V dc universal power supply
Size (HxWxD) 96 mm x 200 mm x 47 mm (3.75 in x 7.9 in x 1.86 in)
Weight 0.65 kg (1.4 lb)
Computer interface RS-232, 9940 I/O ToolKit software included
Safety EN61010-1:2001, CAN/CSA C22.2 No. 61010.1-04
Environmental conditions for best accuracy: 13 °C to 33 °C (55.4 °F to 91.4 °F)
Millivolt range and accuracy –10 mV to 75 mV, ± (0.005 % + 5 µV)
Internal reference junction compensation ± 0.2 °C (± 0.36 °F)
Resistance range and accuracy 0 Ω to 400 Ω ± (0.004 % + 0.002 Ω) 200 Ω to 50 kΩ ± (0.01 % + 0.5 Ω) 50 kΩ to 500 kΩ ± (0.03 %)
Temperature coefficient, voltage:
 –10 °C to 13 °C , +33 °C to 60 °C
(14 °F to 55.4 °F, 91.4 °F to 140 °F)

± (0.001 %/°C + 1 mV/°C)

Temperature coefficient, resistance:
–10 °C to 13 °C , +33 °C to 60 °C
(14 °F to 55.4 °F, 91.4 °F to 140 °F)
0.0008 %/°C + 0.0004 Ω (0 Ω to 400 Ω)
0.002 %/°C + 0.1 Ω (0 Ω to 50 kΩ)
0.06 %/°C + 0.1 Ω (50 kΩ to 500 kΩ)
Excitation current, resistance
1 mA (0 Ω to 400 Ω)
10 µA (0 Ω to 50 kΩ)
2 µA (50 kΩ to 500 kΩ)



Equivalent temperature accuracies for selected sensors derived from primary specifications (Ω, mV)
Temperature, Thermocouples:

Type
Range
Measure accuracies
K
–200 °C to 0 °C (-328 °F to 32 °F)
± 0.61 °C (± 1.10 °F)
0 °C to 1370 °C (32 °F to 2498 °F)
± 0.24 °C (± 0.43 °F)
R
–20 °C to 0 °C (4 °F to 32 °F) ± 1.09 °C (± 1.96 °F)
0 °C to 500 °C (32 °F to 932 °F) ± 0.97 °C (± 1.71 °F)
500 °C to 1750 °C (932 °F to 3182 °F) ± 0.49 °C (± 0.88 °F)
S –20 °C to 0 °C (4 °F to 32 °F)
± 1.05 °C (± 1.89 °F)
0 °C to 500 °C (32 °F to 932 °F) ± 0.95 °C (± 1.71°F)
500 °C to 1750 °C (932 °F to 3182 °F) ± 0.56 °C (± 1.01 °F)
Accuracies are based on internal reference junction compensation. Refer to technical manual for greatly improved
accuracies using external reference junctions.


Accuracies of selected readout/probe combinations (±°C)

Temperature
5616-12
5615-6
5627A-12
5610-9
-200 °C (-328 °F)
0.014
0.025 0.027
n/a
0 °C (32 °F)
0.021
0.021
0.049
0.009
100 °C (212 °F) 0.027
0.028
0.065 0.009
300 °C (572 °F)
0.040 0.043
0.103 n/a
420 °C (788 °F) 0.050 n/a 0.130 n/a
Includes readout accuracy, probe calibration, and probe drift




Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.







Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!


We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!










We Ship World Wide! We Ship World Wide!We Ship World Wide!


We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate".

Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information.

We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.






We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed.

  • Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale.

  • Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections)

  • A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment.

Thank you

ALL MAJOR CREDIT CARDS & PayPal ACCEPTED
Credit Cards






Sell Smarter with Kyozou.
Inventory and Ecommerce Management