Auguste Cryogenics AC 2XL50T-B Cryonos Transport Proben Zellen Lager Behälter ADR LN2

The aluminum containers of the 2XL- | 3XL-B - series from Auguste Cryogenics Medical Family are cryogenic freezer containers for long-term storage of biogenic material in liquid nitrogen - with many possible uses in laboratory and technology.The containers of the Auguste Cryogenics Medical Family stand out off through:• High portability thanks to its low weight and compact dimensions• Long holding times, resulting in high economic efficiency• large storage capacityThe vacuum-insulated aluminum containers of the Medical Family are thus ideally suited for use in medical institutes, biological laboratories, artificial insemination institutes and pharmaceutical facilities. Various containers from the Auguste Cryogenics Medical Family are transportable and have ADR approval.With the AC Medical Family, Auguste Cryogenics presents its new product line vacuum-insulated aluminum container for transport and storage of nitrogen-cooled material. The products of this group were made for long holding times with the lowest possible nitrogen consumption. Static holding times from three weeks to over half a year are depending on Design and equipment possible.The containers of the AC Medical Family can be used in many ways - at insemination as well as in the medical and pharmaceutical field and for various industrial processes. Depending on the purpose and requirements biological material can be stored in the liquid or gas phase of the containers are stored.The containers of the 2XL and 3XL-B models differ primarily due to their different neck diameters of 125 and 216 mm. you are primarily for the systematic storage of large quantities of biological material Material provided, the boxes in the stainless steel racks in the nitrogen liquid phase are cooled.The vessel holds 6 canisters and is equipped with a lockable black lid. Technical Data AC 2XL50T-B Part No. H-AAD1100053 LN2 capacity (liters) 50 Empty weight (kg) 17,3 Neck opening (mm) 125 Outside diameter (mm) 462 Total height (mm) 830 Static evaporation rate (liters / day) 0,45 Static hold time (days) 110 Racks 6 Dimensions of the racks (mm) 82*84 Dimensions of the cryo boxes (mm) 76*76 Floors per rack Cryo-tubes 900 25 mm blood bag racks (single) Levels per 25 ml blood bag rack (single) 25 ml blood bag (single) 25 ml blood bag racks (multi) Levels per 25 ml blood bag rack (multi) Boxes per level 25 ml (multi) 25 ml blood bag (multi) 50 ml blood bag racks (multi) Levels per 50 ml blood bag rack (multi) 50 ml boxes per level (multi) 50 ml blood bag (multi) ADR available as an MDD product Product dimensions (mm) 480*480*985 Shipping volume (m3) 0,227 Weight including packaging (kg) 23,4 Download Datasheet Specifications LN2 capacity (liters): 50 Empty weight (kg): 17,3 Neck opening (mm): 125 Outside diameter (mm): 462 Total height (mm): 830 Static evaporation rate (liters/day): 0,45 Static hold time (days): 110 Racks: 6 Cryo-tubes: 900

WILLKOMMEN BEI CRYONOS

Ihr Lieferant für kryogene Ausrüstung.

Auguste Cryogenics AC 2XL50T-B Cryonos Transport Proben Zellen Lager Behälter ADR LN2

The aluminum containers of the 2XL- | 3XL-B - series from Auguste Cryogenics Medical Family are cryogenic freezer containers for long-term storage of biogenic material in liquid nitrogen - with many possible uses in laboratory and technology.

The containers of the Auguste Cryogenics Medical Family stand out off through:


• High portability thanks to its low weight and compact dimensions
• Long holding times, resulting in high economic efficiency
• large storage capacity

The vacuum-insulated aluminum containers of the Medical Family are thus ideally suited for use in medical institutes, biological laboratories, artificial insemination institutes and pharmaceutical facilities. Various containers from the Auguste Cryogenics Medical Family are transportable and have ADR approval.


With the AC Medical Family, Auguste Cryogenics presents its new product line vacuum-insulated aluminum container for transport and storage of nitrogen-cooled material. The products of this group were made for long holding times with the lowest possible nitrogen consumption. Static holding times from three weeks to over half a year are depending on Design and equipment possible.

The containers of the AC Medical Family can be uséd in many ways - at insemination as well as in the medical and pharmaceutical field and for various industrial processes. Depending on the purpose and requirements biological material can be stored in the liquid or gas phase of the containers are stored.

The containers of the 2XL and 3XL-B models differ primarily due to their different neck diameters of 125 and 216 mm. you are primarily for the systematic storage of large quantities of biological material Material provided, the boxes in the stainless steel racks in the nitrogen liquid phase are cooled.

The vessel holds 6 canisters and is equipped with a lockable black lid.

Technical Data

AC 2XL50T-B Part No. H-AAD1100053
LN2 capacity (liters) 50
Empty weight (kg) 17,3
Neck opening (mm) 125
Outside diameter (mm) 462
Total height (mm) 830
Static evaporation rate (liters / day) 0,45
Static hold time (days) 110
Racks 6
Dimensions of the racks (mm) 82*84
Dimensions of the cryo boxes (mm) 76*76
Floors per rack
Cryo-tubes 900
25 mm blood bag racks (single)
Levels per 25 ml blood bag rack (single)
25 ml blood bag (single)
25 ml blood bag racks (multi)
Levels per 25 ml blood bag rack (multi)
Boxes per level 25 ml (multi)
25 ml blood bag (multi)
50 ml blood bag racks (multi)
Levels per 50 ml blood bag rack (multi)
50 ml boxes per level (multi)
50 ml blood bag (multi)
ADR
available as an MDD product
Product dimensions (mm) 480*480*985
Shipping volume (m3) 0,227
Weight including packaging (kg) 23,4

 

Download Datasheet

Specifications


LN2 capacity (liters): 50
Empty weight (kg): 17,3
Neck opening (mm): 125
Outside diameter (mm): 462
Total height (mm): 830
Static evaporation rate (liters/day): 0,45
Static hold time (days): 110
Racks: 6
Cryo-tubes: 900
Building the GOLD standard of service and quality in cryogenic storage equipment.