  1. 1. Supply voltage: 4-30V
    2. Measuring range: 0-100V
    3. Upper/Lower limit setting range: 0.1-99.9V
    4. Upper/Lower limit output mode: on set range will output high level,otherwise output low level.
    5. Minimum resolution: 0.1V
    6. Refresh rate: 300mS/times
    7. Operating temperature: -40 to +85℃
    8. Input reverse polarity protection: YES
    9. Installation: 2pcs 2mm screws
    10. Size: Length 29mm width 23mm height 10mm

    Applications:
    1. DIY power supply, as the voltage display.
    2. Voltage monitoring.
    3. The device overvoltage or undervoltage alarm, or overvoltage or undervoltage protection.
    4. Battery over-discharge protection.
    5. To be more application you develop.


    Wiring instructions:
    1. As a two-wire meter application, please send a short circuit board R1, connected to the inputs of the input voltage can be displayed. (When using two-wire measuring range do not exceed 30V)
    2. As a three-line header using the R1 plate off the table, the ground and power supply voltage connection 4-30V power supply for the header. Indirect ground voltage to be measured and the test voltage input. (Two to the board pads is the same, can according to the actual wiring by one or two will do)
    3. Adjust panel potentiometer can display the value of prospective effect.
    4. 5PIN pin for the expansion of output, K1, K2 for the onboard external key switch lead, as do key-board, the two PIN via an external button, the button functions with the same function button panel. LV as the lower limit alarm output, output low when below the set value. HV upper limit alarm output, the output is higher than the upper limit set at the low value. LV, HV outputs a control signal for driving the driver circuit, please add lights, or relay other loads.
    5. Upper and lower limit setting method: two keys are pressed, the red light (HV) is lit, press the + or - key to set the desired alarm limit voltage value. And then pressing both buttons simultaneously, yellow (LV) is lit, press the + or - key to set the lower limit alarm voltage required. And then pressing both buttons simultaneously to exit the setting.

    Kindly Note:
    When applying two-wire, the measurement range and scope of supply is the same, so do not exceed 30V measurements. When measuring voltage exceeds 30V, with a three-wire!
We appreciate positive feedback . we always try our best to service our customers .
  so if you have ant question ,PLEASE DON’T HESITATE TO TELL US,
  we are always here to offer help .

We prefer PayPal .For purchasing multiple items , please contact us for a combined invoice .

generally we would like to receive payment thin 48 hours if .

 

We provide airmail service with good package . The items will be shipped within the nest

2 business days after we received the payment . when you buy multiple items ,your shipping

cost will be combined with discount .

SHIPPING TIME (weekends/holidays excluded)

   
   

Country Name

Shipping Time

Country Name

Shipping Time

   

USA/Canada

10 -15d

Spanish/Portugue

10-25d

   

East/South Asia

10 -15d

France/West Asia

10-25d

   

United Kingdom

10 -20d

Italy

10-30d

   

Australia/New Zealand

10 -15d

West Asia/Middle East

15-25d

   

Most Country of West/North Europe

10-20d

South America and Africa

15-30d

   

East /Middle Europe/Russia

10-25d

     

 

  • NEW, GOOD QUALITY, ORIGINAL PACKAGE
  • LARGE STORE AND THE LOWEST PRICE
  • NO-QUESTION-REFUND,
  •             FOR LARGE QUANTITY ,OFFER BETTER PRICE,ORIGINAL      
     PACKING(TAPE REEL/TUBE/TRAY)
     

We specialize in electronic components . ICs, Capacitors, Diodes, Resistors, LEDs,

Transistors, and so on. Especially in Hard To Find Parts . we only sell

NEW , ORIGINAL parts . please buy with confidence .We offer NO-QUESTION-REFUND

 

DataCaciques