Dental Satelec Acteon Ultrasonic Scaler Tips Surgery Tips Extraction Sinus Lift


Feature:
  • Almost the same as original tips.
  • Friction resistant and Long life.

Description:  

Scaling    

Fit:  For Satelec Acteon Scaler

Function: 

#1 Universal Tip : 
#1S Slim: 
#2 Voluminous Calculus: 
#3 Colorations:
#10P Scaling Pockets: 
#10X Interproximal
  • Interproximal spaces scaling thanks to its anatomic shape.
  • With its flat active part, it is particularly suitable for the interproximal spaces and supra-gingival scaling.
  • Its anatomical shape allow fast and efficient procedure.
#10Z Scaling Pockets: 

Periodontics   

Fit:  For Satelec Acteon Scaler

Function: 

H3 for Anterior Teeth:  
  • Ideal tip to begin with, for the treatment of anterior teeth. The guiding edge is used parallel to the pocket.
  • The H3 tip is descended into the periodontal pocket without risk of injury to the ligament. The cavitation will lift the debris out.
PD12 for Anterior Teeth:  
  • Brand: Refine
  • Model: PD12
  • Similar to Satelec Acteon Periodontal Tip H3
  • Fit for Satelec Acteon/ woodpecker DTE
  • Anterior Teeth. Ideal to begin with for the periodontal debridement treatment of anterior teeth. 
  • These ultrasonic periodontal tips are aimed at removing microbial biofilms, which cause gingivitis and periodontitis.
H4L Left Angled: 
  • Left angled. Recommended for the treatment of all surfaces and furcations:
    -Maxillary: vestibular and distal surfaces of sector 2, pivote at 13 then palatal and mesial surfaces of sector 1.
    -Mandibular: lingual and mesial surfaces of sector 3, pivote at 43 then vestibular and distal surfaces of sector 4.
H4R Right Angled: 
  • Right angled. Follows the H4L tip in the treatment sequence for the treatment of all surfaces and furcations:
    - Maxillary: palatal and mesial surfaces of sector 2, pivote at 13 then vestibular and distal surfaces of sector 1.
    - Mandibular: vestibular and distal surfaces of sector 3, pivote at 43 then lingual and mesial surfaces of sector 4.
 Periomaintenance

Fit:  For Satelec Acteon Scaler

Function: 

TK1-1S Short Probe: 
  • Micro-tip recommended for examining shallow to moderate pockets (<4mm) and for the maintenance of simple cases.
TK1-1L Long Probe: 
  • Micro-tip for examining and maintenance of moderate to deep pockets (>4mm).
  • It is a diagnosis aid during the debridement and irrigation of pockets.
  • The TK1 probe tips are used without pressure following the contour of the pockets and skimming over the root surface.
TK2-1L Left-angled: 
  • Premolars and molars. Left-angled.
  • Recommended for maintenance of moderate to deep pockets and furcations.
  • - maxillary: vestibular and distal surfaces of sector 2, pivote at 13 then palatal and mesial surfaces of sector 1.
  • - mandibular: lingual and mesial surfaces of sector 3, pivote at 43 then vestibular and distal surfaces of sector 4.
TK2-1R Right-angled: 
  • Premolars and molars. Right-angled.
  • Complements the TK2-1L tip. Mini-tip used to treat moderate to deep pockets and furcations.
  • - maxillary: palatal and mesial surfaces of sector 2, pivote at 13 then vestibular and distal surfaces of sector 1.
  • - mandibular: vestibular and distal surfaces of sector 3, pivote at 43 then lingual and mesial surfaces of sector 4.
Bone Surgery Tips

Fit:  
  • Acteon Satelec Piezotome 2.
  • Acteon Satelec Piezotome Solo (LED).
  • Acteon Satelec Piezotome Cube.
  • Acteon Implantcenter 2.
Function: 
  • V-BS1:Saw intended for cutting of cortical bone in surgical orthodontics, pre-implant surgery,and bone distraction.
  • V-BS2L: Bone saw with four teeth, used for cutting the ramus cortical bone. Left  oriented, it is used to create vertical and horizontal osteotomy lines on the patient’s right mandible.
  • V-BS2R: Bone saw with four teeth, used for cutting the ramus cortical bone. Right  oriented, it is used to create vertical and horizontal osteotomy lines on the patient’s left mandible.
  • V-BS4: Circular scalpel angled at 130°, for osteoplasty and harvesting of bone particles or chips. Ridge osteoplasty, periodontal surgery, cysts exerisis, etc.
  • V-BS5:Flat scalpel for fine osteotomies.
  • V-BS6: Curved scalpel particularly effective for substantial osseous reshaping. This tip is used to perform osteoplasties and reshaping of the bone not assuring the tooth support. It can also be used to mark a prosthetic reference point on enamel, if needed, where osteoplasty will begin.
Sinus Lift Tip

Fit:  
  • Acteon Satelec Piezotome 2.
  • Acteon Satelec Piezotome Solo (LED).
  • Acteon Satelec Piezotome Cube.
  • Acteon Implantcenter 2.
Function: 
  • V-SL1: Diamond-coated tip for vestibular bone window cut and for attenuation of sharp angles.
  • V-SL2: Diamond- coated ball tip for smoothing the vestibular bone window and precise osteoplasty. Ball diameter: 1.5mm. Laser mark every 2mm.
  • V-SL3: Plateau-tip, non- cutting, for sinus membrane elevation on the vestibular bone window’s edges.Plateau diameter: 5 mm.
  • V-SL4: Non-cutting spatula, oriented at 90°, for sinus membrane elevation inside the sinus.Spatula diameter: 4 mm.
  • V-SL5: Non-cutting spatula, oriented at 135°, used for sinus membrane elevation inside the sinus and for disengagement of anatomical structures.Spatula diameter: 4 mm.
Extraction Tips

Fit:  
  • Acteon Satelec Piezotome 2.
  • Acteon Satelec Piezotome Solo (LED).
  • Acteon Satelec Piezotome Cube.
  • Acteon Implantcenter 2.
Function: 
  • LC1To be inserted deeply and with great care, along the periodontal ligament, between the root and the alveolar bone.Length of active part: 9mm
  • LC1/90To be inserted deeply and with great care, along the periodontal ligament, between the root and the alveolar bone. Length of active part: 9mm.
  • LC2The particularly slim LC2 allows access to the tight spaces between the root and the alveolar bone without risk of damaging cortical bone. Length of active part: 10mm
  • LC2LOriented at 45° to the left or to the right, the LC2L/LC2R facilitates access to the posterior areas. The tip’s slimness respects the morphology of cortical bone and offers working comfort in the sectors with reduced visibility.Length of active part: 10mm
  • LC2R: Oriented at 45° to the left or to the right, the LC2L/LC2R facilitates access to the posterior areas. The tip’s slimness respects the morphology of cortical bone and offers working comfort in the sectors with reduced visibility.Length of active part: 10mm


FDA Statement:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Seller's name: spring-dent2021
City State: Zhengzhou, Henan China
Telephone number:+86371-61770155

DataCaciques