Features
1. Brand New; Durable; 100% CE High Quality.
2. Easily attachable to any 2 Hole Borden handpiece connector


Specifications for Led High handpiece
Description:
- NSK style LED Pana Max high speed handpiece
- 2 Hole standard push button handpiece
- Triple water spray
- It has unique appearance design and fluent outline.
- Smooth as silk, it has excellent texture.
- With people-friendly design, easy for operation.
- With best quality cartridge, easier for cleaning.
- With high-speed turbine rotation, it has better performances.
- Chucking power of chucking needle is 20N-45N.
- It is noise-free and stable.
- Applicable Bur: 1.6mm and should be conformed to ISO standard.
- Idling speed of handpiece should be no less than 350,000 rotations under working air pressure of 25- 30 pressure atmosphere.
- Special for operations such as clamping high-speed dentistry machine needle to drill and grind teeth in department of stomatology, it is more professional.
- It is only for people who have dentistry medical qualification.

Features:
1.Low noise,Standard head
2.Triple water spray, LED handpiece integrate E-generator
3.2-Hole Push Button system
4.Unique electric generator, just a little air can generate sufficient power
5. 135°C Autoclavable
6. For the LED bulb, continuous use of up to ten thousand hours, don't need to change the pipeline, easy to use; The world dental chair two holes, four holes.
7.Warranty:one year for handle; three months for cartridge

Technical :
Chuck Type: Push Button
Working pressure: 0.25 Mpa to 0.3 Mpa
Speed: 280,000-350,000R.P.M
Spray: Three water Spray
Bur size:Φ1.595-Φ1.600mm
Noise: ≤ 70 dB
Hole:2 Hole
BEARING: Stainless steel bearing


Specifications for Air Scaler
Specifications
Available air pressure: 3.2 KG/c㎡
Sterilization: High-temperature (135 Degree) and High-pressure repeatedly
Available Air Pressure: 2.5~3.5KG/c㎡
Air Pressure: 2.8KG/c㎡
Air Volume: 15~24L/Min
Sound Level: 65-68 dB
Net weight: 0.12kg
Gross weight: 0.15kg
Packing size: 170*80*30MM
 
Caution
1. The air supply must be free of moisture. The water supply must be filtered.
2. Place the most priority of the patients safety
3. Do not exceed 0.28Mpa(2.9kgf/cm2)when setting the air pressure at the dental unit.
4. If any abnormalities are found in use, stop using immediately and contact your dealer.
5. Do not drop, hit, or subject to excessive shocl.
6. Check the vibration, noise and overheating outside of the patient's mouth before initial use. If any abnormalities are found in use, stop using immediatel and contact your dealer.
7. Be sure to stop the air supply, and replace the tip ro the coupling joint.
8. Watch out the sharp point of the tip.
9. Do not use a spray lubricant. Limited air discharge orifice size of the scaler forces the propellant pressure to build up inside, and the scaler may fly off.
10. Do not clean or wipe the scaler with highly oxidized or acid water or strilizing solution.
 
 
Installation
1. Holding the tip-end, turn clockwise and fasten securely tighten with wrench.
2. Shout off the water supply. Adjust air pressure to 2.8KG/CM2 Adjust the water flow until a fine mist ejects from the tip.
Lubrication
Supply 2-3 drips into the drive air tube once or twice a day or spray lubricant into inlet hole of handpiece for about two seconds.
 


Specifications for Low Speed handpieces
- E-type connector
- Push Button type
- Precise technology, Steady, no vibration while revolving, offering a steady operation.
- Suitable for any E-type handpiece accords with ISO standard
- 135°C Autoclavable, suitable for both steam and chemical autoclave
 
Contra angle handpiece
- Low Speed 22,000-27,000 rpm.
- The shank of the instrument mounted therein is 2.35 mm
- Fastening of the instruments with a turning latch
- Autoclavable 135°C
- For any lab or E-type motors
 
Straight Nosecone
- Working pressure: 0.3MPa ;
- 0.25MPa (Measure meter is installed at the end of air motor to measure the air pressure).
- Revolution: about 22000-27000r/min (adjustable between clockwise or anticlockwise)
- Noise: ≤68dB
 
Air Mortor
- Supply air pressure: 245-392KPa (2.5-4kgf/CM2)
- 1:1 Direct Drive
- 2 hole
 

Packing List:
- 1X LED high speed push button clean head pieces 2Hole compatible with NSK PANA MAX
- 1X NSK Style air scaler
- 1X NSK Style contra angle with blue band
- 1X NSK Style strainght angle piece
- 1X NSK Style air motor 2 hole
- 1X A Bearing
 
FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
  
NOTE: Due to manufacturer's packaging update, the actual product packaging may differ from the picture, we try to ensure that the product is the same as the picture as much as possible. The products are the same in use and function, please refer to the actual product received.If you mind these,pls don't place an order,thank you for your assistance!  
If any problem,please feel free to contact us!

 

DataCaciques