Waste Oil Burner

1. PurposeTurn on the power supply, the fuel supply of the burner is heated, and then ignited. The air solenoid valve opens automatically. The oil mist sprayed by the nozzle is broken by the electric spark and ignited to form a flame. It is mainly used for boilers as a heater of the boiler.

2. Classification:Our's burner burns waste oil, including waste engine oil, used motor oil, waste hydraulic oil, waste vegetable oil, waste gear oil, normal diesel etc.

3. Application:Boilers, heaters, dryers, incinerator etc.

4. Components Chassis, small fuel tank, computer control, flame control system, fan, oil pump motor, etc.

5. Heat output 50,000 kcal, 100,000 kcal, 200,000 kcal, 300,000 kcal, 500,000 kcal, 5, 100,000 kcal are very popular in Europe.

6. Fan diameter Generally is114MM, 100MM 90MM optional, the length of the fan is 170mm, the flange to the head of the fan is 135mm

7. Total power Small fuel tank heating pipe 1KWLarge oil tank heating 500WFan motor 180WOil pump motor 90W

8. Flame length YB-05 and YB-10 in 0.4-1.0 meters, depend on burner power

9. Air compressor

The burner need working with your own compressor.


Detail:

YB-10
Model Number
YB-10 ( one air stage )
Oil consumption

10 L/H
Output power (kw)

120 kw
Output heat (kcal)
103,000kcal
Outpur heat (btus)

405,000btu
Nozzles
1
Blast Tube Diameter (mm)
114mm
Fuels
used engine oil, used vegetable oil, used crankcase oils, used Glycerin, used Hydraulic oil, used synthetic oils, waste machine shop cutting oil, waste mineral spirits solvent, waste grades #1, #3, #4 heating oils, waste mixed heavy oil, normal disel, etc
Voltage
110-120V(50-60hz), 220-240V(50-60hz) optional
Using
waste oil boiler, steam boiler, incineratorand other heating equipment.

Packing:

Package when send by DHL


Foam in, Carton box out

28kg,  57*56*43cm


Notice:

1. The ignition transformer belongs to high-voltage ignition, and the output voltage is 12 kV, which can cause danger. It is strictly forbidden to touch it during work.

2. When connecting the power supply, the voltage level of the burner must be determined first to avoid damage to the equipment and other dangers caused by the use of different levels of voltage.

3. The equipment has been adjusted before leaving the factory. Customers can fine-tune the air pressure valve and damper according to the actual combustion situation. Try to avoid adjusting the ignition rod, flame stabilizing disc spacing, etc.

4. There is high voltage in the electrical control box, and it should be avoided to open the box; during the maintenance, professionals need to power off for maintenance.

5. To control the start and stop of the burner, it is necessary to use the reserved control terminals in the control box (one end is connected to the blue and white wires) to listen to the external normally closed terminal to avoid the control of the burner by turning on and off the power supply. Start and stop. It is forbidden to introduce power into the start-stop control terminal.

6. When the burner is working, it is strictly forbidden for people and objects to stay and place in front of the fan.


Generally, our stocks' voltage is 220-240v. Please inform us if you need 110v or other.