Brush fan speed adjust mode :
Speed adjust mode:
The brush fan interface adjusts the fan speed by adjusting the voltage duty cycle. After starting up, press the wind speed key to adjust the current 5 speeds of the internal fan. The wind speed is adjustable in 1-5 level in each mode.
Control panel function button instruction :
Control panel operation logic:
A Power key: Short press to turn on, short press again to turn off。
B Speed up key: Increase in air supply 。
C Speed lower key: to lower the air supply
D Mode key: Cycle and hold for one second to switch modes: air blow, power saving, economy,
strong wind; long press for 3 seconds to enter the low voltage adjustment state, after adjusting
the low voltage protection value, long press the mode button for 3 seconds to remember and exit
the low voltage setting
E Temperature higher key: Increase the set temperature , and adjust the low-voltage protection
value to increase by 0.1V.
F Temperature lower key: lower the set temperature , and adjust the low-voltage protection value to lower by 0.1V. G low voltage protection value, low voltage recovery value adjustment: Long press the mode key for 10 seconds to enter the adjustment interface (---), adjust the temperature plus and minus keys to set the low voltage protection value.
Fault indication description :
low-voltage protection, the power supply voltage is lower than the set value (default: 21.5V), the battery low indicated red light will be on, the fan stops output in the low-voltage state, the analog voltage of the frequency modulation line stops output, and the external unit enters the standby state and stops working. When the voltage exceeds again to low voltage recovery value (default: 25.5V), the system restarts and resumes operation. When the control board detects a fault, it stops working, the fault icon flashes, and the fault code will be displayed on the digital display.
The meaning of the code is as follows:
E-C: Temperature probe failure
E-1: Low voltage protection.
E-2: Controller over current protection.
E-3: Controller locked-rotor protection.
E-4: Controller low voltage protection. .
E-5: Poor system cooling.
E-7: Phase failure