High precision  Luxmeter U116  analog of Lutron, Advantest, Avtech, HP Agilent, NoiseCom, General Radio, Boonton, Anritsu, Fluke and general Electric, but  has the same or better characteristics.

This device can be used for wide measurement range.

  Is designed to measure light produced by incandescent lamps and natural light sources which are located at random with respect to light detector luxmeter.
    Analog pointer.
    Measuring range from 5 to 100.000 lx.
    Power light energy.
    Dimensions  210x125x85mm, weight 0.85 kg.

    Luxmeter U116 is designed to measure light produced by incandescent lamps and natural light sources which are located at random with respect to light detector luxmeter.
    Portable photoelectric luxmeter U116 general purpose used to control lighting in industry, agriculture, transport and other economy sectors, as well as for research in science, engineering and design organizations.
    Device luxmeter U116 climatic performance type – Y category 3.1according to GOST 15I50-69 is designed for working temperatures from minus 10 to plus 35 ° C, relative humidity up to 80% at 20 ° C.

Condition: NEW  (not used, an old stock). Tested and 100% workable.

Technical characteristics of devices luxmeter U116 :

 
    Measurement range and total nominal attenuation coefficient used two nozzles is shown in table 1 and in footnote to table 1.
    Device luxmeter U116 accuracy class - 10 according to GOST 8.401.

    Table 1

Measurement range, lk

Basic
    

Not basic

without attachments with an open photocell
    

with attachments

КМ
    

КР
    

КТ

5lk-30lk
    

50lk-300lk
    

500lk-3000lk
    

5000lk-30000lk

20lk-100lk
    

200lk-1000lk
    

2000lk-10000lk
    

20000lk-100000lk

 

Note. KM, KP, KT - symbol used in conjunction nozzles to create common nominal attenuation coefficient 10, 100, 1000, respectively.
Device luxmeter U116 scale is uneven, graduated in lux: one scale has 100 divisions, second - 30 divisions.

Mark "5" scale 0-30, mark "20" scale 0-100, corresponding to measurement ranges initial values ​​ are indicated more precisely.
Device luxmeter U116 acceptable error limits at basic measurement range 5lk -30lk and 20lk -100lk (without attachments) must not exceed ± 10% of measured light value.
Acceptable changes in luxmeter measurements caused by ambient air temperature deviation of 20 ° C to any temperature range from minus 10 to plus 35 ° C, does not exceed ± 1% of measured value per 1 ° C.
Luxmeter U116 dimensions:
210x125x85mm - luxmeter;
185 x 105 x 55mm - photocell luxmeter, with nozzles KM or Kp, or KT;
300 x 155 x 135 - luxmeter box.
Device luxmeter U116 weight: 0.85 kg - without box, 1.75 kg - with box.

Delivery term

This device is available in stock right now.

I can send it at one day after your payment.

 This device also can be named as:    U-116, U 116, U116,  ю-116, ю 116, ю116.
         Photos

If necessary we can take photos of a device from various angles.