Brocade 300 SM-310-0000 310 24-Port 8Gb Fibre Channel SAN
Switch 24 Ports Active
Model: 300
P/N: SM-310-0000
P/N: 80-1001931-04

In Full Working Order
Supplied With 2 Years Warranty
24 Ports Active

Has Small Dent In Front Of Switch
Second Ports on Demand license, Full Ports on Demand license, Fabric license, Enhanced Group 
Management license & 8 Gig FC License

INCLUDED

  • 1 x Brocade 300 SM-310-0000 310 24-Port 8Gb Fibre Channel SAN Switch 24 Ports Active
DESCRIPTION

The Brocade 300 is a 24-port switch that provides an affordable, flexible foundation for entry-level SANs, and an edge switch for core-to-edge SAN environments. It delivers 8 Gbps performance in an energy-efficient, optimized 1U form factor to support the most demanding server and virtual server deployments.

Systems Architecture

Fibre Channel ports

  • Switch mode (default): 8-, 16-, and 24-port configurations (8-port increments through Ports on Demand [PoD] licenses); E_, F_, M_, FL_ Ports
  • Brocade Access Gateway Default Port Mapping: 16 F_Ports, 8 N_Ports

Scalability

  • Full fabric architecture with 239 switches maximum

Certified maximum

  • Single Brocade FOS fabric: 56 domains, 19 hops
  • Single Brocade M-Enterprise OS (M-EOS) fabric: 31 domains, 3 hops
  • Larger fabrics certified as required; consult Brocade or OEM SAN design documents for configuration details

Performance

  • 1.063 Gbps line speed, full duplex; 2.125 Gbps line speed, full duplex; 4.25 Gbps line speed, full duplex; 8.5 Gbps line speed, full duplex; auto-sensing of 1, 2, 4, and 8 Gbps port speeds; optionally programmable to fixed port speed; speed matching between 1, 2, 4, and 8 Gbps ports

ISL Trunking

  • Brocade Frame-based Trunking with up to eight 8 Gbps ports per ISL trunk with optional license; up to 64 Gbps per ISL trunk (8 ports × 8 Gbps [data rate])
  • Exchange-based load balancing across ISLs with DPS included in Brocade Fabric OS

Aggregate bandwidth

  • 192 Gbps: 24 ports × 8 Gbps (data rate)

Maximum fabric latency

  • 700 ns with no contention, cut-through routing at 8 Gbps

Maximum frame size

  • 2112-byte payload

Frame buffers

  • 700 dynamically allocated, 484 maximum per port

Classes of service

  • Class 2, C lass 3, C lass F (inter-switch frames)

Port types

  • FL_Port, F_Port, M_Port (Mirror Port), and E_Port; optional port type control
  • Brocade Access Gateway mode: F_Port and NPIV-enabled N_Port

Data traffic types

  • Fabric switches supporting unicast, multicast (255 groups) and broadcast

Media types

  • 8 Gbps: Brocade 300 requires Brocade hot-pluggable SFP+, LC connector; 8 Gbps SWL, LWL, ELWL
  • 4 Gbps: Brocade 300 requires Brocade hot-pluggable SFP+, LC connector; 4 Gbps SWL, LWL, ELWL

USB

  • 1 USB port for firmware download, supportSave, and configuration upload/download

Fabric services

  • Brocade Advanced Performance Monitoring (including Top Talkers); Adaptive Networking (Ingress Rate Limiting, Traffic Isolation, QoS); BB credit recovery; Brocade Advanced Zoning (default zoning, port/WWN zoning, broadcast zoning); Bottleneck Detection; Dynamic Path Selection (DPS); F_Port Trunking; Extended Fabrics; Fabric Watch; FDMI; Frame Redirection; FSPF; IPoFC; ISL Trunking; Management Server; NPIV; NTP v3; Port Fencing; Registered State Change Notification (RSCN); Reliable Commit Service (RCS); Simple Name Server (SNS)

Management

  • HTTP, SNMP v1/v3 (FE MIB, FC Management MIB), Telnet; Auditing, Change Management tracking, Syslog; Brocade Advanced Web Tools, Brocade Fabric Watch; EZSwitchSetup wizard, Brocade Network Advisor SAN Enterprise, or Brocade Network Advisor SAN Professional/Professional Plus;command line interface; SMI-S compliant; Administrative Domains; trial licenses for add-on capabilities

Security

  • DH-CHAP (between switches and end devices), FCAP switch authentication, FIPS 140-2 L2-compliant, HTTPS, IPsec, IP Filtering, LDAP with IPv6, OpenLDAP, Port Binding, RADIUS, TACACS+, User-defined Role-Based Access Control (RBAC), Secure Copy (SCP), Secure RPC, SFTP, SSH v2, SSL, Switch Binding, Trusted Switch

Management access

  • 10/100 Mbps Ethernet (RJ-45), in-band over Fibre Channel; serial port (RJ-45); USB

Diagnostics

  • POST and embedded online/offline diagnostics, including RAStrace logging, environmental monitoring, non-disruptive daemon restart, FCping and Pathinfo (FC traceroute), port mirroring (SPAN port)

Enclosure

  • Non-port to port side airflow; 1U, 19-inch EIA-compliant, power from port side

Size

  • Width: 42.88 cm (16.88 in)
  • Height: 4.29 cm (1.69 in)
  • Depth: 30.66 cm (12.07 in)

System weight

  • 4.2 kg (9.30 lb), without SFP/SFP+ media

Temperature

  • Operating: 0°C to 40°C (32°F to 104°F)
  • Non-operating and storage: −25°C to 70°C (−13°F to 158°F)

Boot Log

SANSW02:root> switchshow

switchName:     SANSW02

switchType:     71.2

switchState:    Offline

switchMode:     Native

switchRole:     Disabled

switchDomain:   30 (unconfirmed)

switchId:       fffc1e

switchWwn:      10:00:00:05:33:a0:cb:4f

zoning:         ON (Fabric1_Tecteo)

switchBeacon:   OFF

 

Index Port Address Media Speed State     Proto

==============================================

   0   0   1e0000   id     8G   UNKNOWN     FC  Testing  Disabled

   1   1   1e0100   id     8G   UNKNOWN     FC  Testing  Disabled

   2   2   1e0200   id     8G   UNKNOWN     FC  Testing  Disabled

   3   3   1e0300   id     8G   UNKNOWN     FC  Testing  Disabled

   4   4   1e0400   id     8G   UNKNOWN     FC  Testing  Disabled

   5   5   1e0500   id     8G   UNKNOWN     FC  Testing  Disabled

   6   6   1e0600   id     8G   UNKNOWN     FC  Testing  Disabled

   7   7   1e0700   id     8G   UNKNOWN     FC  Testing  Disabled

   8   8   1e0800   id     8G   UNKNOWN     FC  Testing  Disabled

   9   9   1e0900   id     8G   UNKNOWN     FC  Testing  Disabled

  10  10   1e0a00   id     8G   UNKNOWN     FC  Testing  Disabled

  11  11   1e0b00   id     8G   UNKNOWN     FC  Testing  Disabled

  12  12   1e0c00   id     8G   UNKNOWN     FC  Testing  Disabled

  13  13   1e0d00   id     8G   UNKNOWN     FC  Testing  Disabled

  14  14   1e0e00   id     8G   UNKNOWN     FC  Testing  Disabled

  15  15   1e0f00   id     8G   UNKNOWN     FC  Testing  Disabled

  16  16   1e1000   id     8G   UNKNOWN     FC  Testing  Disabled

  17  17   1e1100   id     8G   UNKNOWN     FC  Testing  Disabled

  18  18   1e1200   id     8G   UNKNOWN     FC  Testing  Disabled

  19  19   1e1300   id     8G   UNKNOWN     FC  Testing  Disabled

  20  20   1e1400   id     8G   UNKNOWN     FC  Testing  Disabled

  21  21   1e1500   id     8G   UNKNOWN     FC  Testing  Disabled

  22  22   1e1600   id     8G   UNKNOWN     FC  Testing  Disabled

  23  23   1e1700   id     8G   UNKNOWN     FC  Testing  Disabled

 

SANSW02:root> chassisshow

 

POWER SUPPLY  Unit: 1

Time Awake:             0 days

 

FAN  Unit: 1

Time Awake:             0 days

 

FAN  Unit: 2

Time Awake:             0 days

 

FAN  Unit: 3

Time Awake:             0 days

 

CHASSIS/WWN  Unit: 1

Header Version:         2

Factory Part Num:       40-1000165-14

Factory Serial Num:     ALJ1939G081

Manufacture:            Day: 16  Month:  8  Year: 2011

Update:                 Day: 14  Month:  3  Year: 2017

Time Alive:             1483 days

Time Awake:             0 days

ID:                     BRD0000CA

Part Num:               SLKWRM0000300

 

SANSW02:root> licenseshow

ebbbdbyyfcgceo:

    Second Ports on Demand license - additional 8 port upgrade license

ebbbdbyyfsgce4:

    Full Ports on Demand license - additional 16 port upgrade license

RSbeQeSRQeSTcfRm:

    Fabric license

r9gFFALAHX9HRZ4afJSg4mCFggRfTWaGBJYSN:

    Enhanced Group Management license

M4rYtTAKHtWmfSEXR7PABFNafFLXTTf9BA7tJ:

    8 Gig FC license

 

SANSW02:root> switchstatusshow

Switch Health Report                        Report time: 02/21/2022 03:10:04 PM

Switch Name:    SANSW02

IP address:     10.6.252.22

SwitchState:    HEALTHY

Duration:       00:00

 

Power supplies monitor  HEALTHY

Temperatures monitor    HEALTHY

Fans monitor            HEALTHY

Flash monitor           HEALTHY

Marginal ports monitor  HEALTHY

Faulty ports monitor    HEALTHY

Missing SFPs monitor    HEALTHY

Error ports monitor     HEALTHY

 

SANSW02:root> 

VAT @ 20% INCLUDED IN PRICE - VAT INVOICE PROVIDED
£250 excluding VAT
             
VAT IS NOT PAYABLE BY PURCHASERS OUTSIDE OF THE UK
TH 274122 274126