Dixell XR40CX-5N1C1 230V Digital Thermostat Controller Compressor Defrost Probes
   Model XR40CX, format 32 x 74 mm, is microprocessor based controller, suitable for applications on medium or low temperature refrigerating units. It has 2 relay outputs to control compressor and defrost, which can be either electrical or reverse cycle (hot gas). It is also provided with three NTC or PTC probe inputs, the first one for temperature control, the second one, to be located onto the evaporator, to control the defrost termination temperature, the third one, optional, to connect to the HOT KEY terminals to signal the condenser temperature alarm or to display a temperature. The digital input can operate as fourth temperature probe.The HOT KEY output allows to connect the unit, by means of the external module XJ485-CX, to a network line ModBUS-RTU compatible such as the Dixell monitoring units of X-WEB family. It allows to program the controller by means the HOT KEY programming keyboard.The instrument is fully configurable through special parameters that can be easily programmed through the keyboard.

Suitable for appliances including
for applications on medium or low temperature refrigerating units
 
 
Specification
Housing: self extinguishing ABS.
Case: XR40CX frontal 32x74 mm; depth 60mm;
Mounting: XR40CX panel mounting in a 71x29mm panel cut-out
Protection: IP20; Frontal protection: XR40CX IP65
Connections: Screw terminal block ± 2,5 mm2 wiring.
Power supply: according to the model: 12Vac/dc, ±10%; 24Vac/dc, ±10%; 230Vac ±10%,
50/60Hz, 110Vac±10%, 50/60Hz
Power absorption: 3VA max
Display: 3 digits, red LED, 14,2 mm high; Inputs: Up to 4 NTC or PTC probes.
Digital input: free voltage contact
Relay outputs: compressor SPST 8(3) A, 250Vac; or 20(8)A 250Vac
Data storing: on the non-volatile memory (EEPROM).
Kind of action: 1B; Pollution grade: 2;Software class: A.;
Rated impulsive voltage: 2500V; Overvoltage Category: II
Operating temperature: 0÷60 °C;Storage temperature: -30÷85 °C.
Relative humidity: 20-85% (no condensing)
Measuring and regulation range: NTC probe: -40÷110°C (-40÷230°F);
PTC probe: -50÷150°C (-58÷302°F)
Resolution: 0,1 °C or 1°C or 1 °F (selectable); Accuracy (ambient temp. 25°C): ±1 °C ±1 digit
The X-REP output excludes the TTL output.It’s present in the following codes:
XR40CX- xx2xx, XR40CX –xx3xx;
 
COMPRESSOR
The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again.
In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters “COn” and “COF“.
 
DEFROST 
Two defrost modes are available through the “tdF” parameter: defrost through electrical heater (tdF= EL) and hot gas defrost (tdF = in). Other parameters are used to control the interval between defrost cycles (IdF), its maximum length (MdF) and two defrost modes: timed or controlled by the evaporator’s probe (P2P).At the end of defrost dripping time is started, its length is set in the FSt parameter. With FSt =0 the dripping time is disabled.

SAFETY PRECAUTIONS
• Check the supply voltage is correct before connecting the instrument.
• Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation.
• Warning: disconnect all electrical connections before any kind of maintenance.
• Fit the probe where it is not accessible by the End User. The instrument must not be opened.
• In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S.r.l.” (see address) with a detailed description of the fault.
• Consider the maximum current which can be applied to each relay (see Technical Data).
• Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining.
• In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel with inductive loads could be useful.
 
Package Include
1 X Dixell XR40CX Digital Thermostat Controller(Whole package with accessories)with probes
We accept many different payment ways,such as payoneer,paypal,credit card,and bank card etc.
Payment should be made within 3 days after you order.
Otherwise a Unpaid Item case will be opened to you by ebay automaticlly,please understand.
 
Please Note
Import duties,taxes and charges are not included in the item price or shipping charges.These charges are the buyer's responsibility.
We are not responsible for custom duties and related taxes.Orders will be shipped as a gift or as a sample. In general, no custom duties and tax will be charged.
For AU,US,UK,DE,CA,FR,IT,Spain,Japan,Korea,New Zealand buyers, we use Standard(Delivery time is 5-12 business days) or express delivery(Delivery time is 3-5 business days).For other countries' buyers, we use Standard shipping or Economy shipping(Delivery time varies from 7 to 25 business days)or Express delivery(Delivery time is 3-5 business days).
 
We will ship according to your EBAY address,but sorry that we can not accept P.O.BOX address.
 
SERVICE TRANSIT TIME is provided by the carrier and excludes weekends and holidays. Transit times may vary, particularly during the holiday season.
Please make sure it is correct and include phone number for delivery.
If you do not receive your order in the estimated time, please contact us first, we would do our best to serve you solve the problem.
Please include your special requests in eBay note if there is any.
Buyer Guarantee
We assure you that we are a honest and super reliable seller on ebay, any problems can be solved in a satisfied way for you and any loss will not be brought to you as long as you will kindly contact us via ebay message.Please kindly contact us firstly if your purchasing is in trouble before leaving any bad feedback including neutral and negative feedback and leaving 3 stars or less stars to me on 4 criteria.

Return Policy
Please return the item within 30 days after receiving if you are not satisfied with your purchasing.All returns are expected to be in original conditions, please email us first for return address and instructions,thanks for your understanding.
We automatically submit positive feedback to our buyers once the payment is cleared.
If anything about your transaction did not meet your expectations, PLEASE LET US KNOW AND GIVE US THE OPPORTUNITY TO MAKE THINGS RIGHT before you leave feedback - We are 100% sure that we can solve any issue regarding your purchase.
Our customer-oriented service strives for positive feedbacks with all 5 star ratings.
Please feel free to contact us via eBay message once you have any question before you giving us negative feedback or open case.
We will reply you in 24 business hours.
Customer Service Hours: Monday-Saturday: 9:00AM - 18:00PM BST (Beijing Standard Time)
About weekend,we will also answer your question,but it may delay for a short time.
PushAuction