1PC NEW MMT-DPW DC Brushless Drive DC10/50DPW15BL Torque Control Mode
This product has three working modes: speed control, current control, and open-loop control. It can realize control functions such as braking, direction, prohibition, maximum current limit setting, one-stage amplification, two speed settings, etc.; there are also auxiliary functions such as external potentiometer, internal potentiometer, external analog, external PWM/pulse signal, and acceleration ramp delay function, as well as overload protection, overheating protection, blockage protection, etc.; various functions are easy to operate; high speed control, the maximum speed of a pair of poles motor can reach For details, please refer to the related content.
 
I. Performance parameters.
Power supply voltage VCC: 10-50VDC (error less than 5% is good)
Maximum output voltage is: Vout = 0.95 X VCC
Continuous output current: Icont=7A
Short-time acceleration of the maximum output current: Imax = 15A
Switching frequency: 39KHz
Maximum speed (one pole motor): 120,000rpm
Minimum opening speed: refer to the list of switch S5 and S6 settings at the back
Hall supply voltage range: 7-12VDC Maximum current 30mA
Locked blockage protection time: 1.5s
External PWM signal Fixed frequency: 200-6KHZ
Duty cycle: 0% - 100%
Pulse signal frequency Frequency: 1K-99KHz Duty cycle: 50%
Ambient temperature: Operating: -25-+450C Storage: -40-+850C
Humidity range: 20-80%
Analog input: 0-- +5V DC
Acceleration time ramp range: approx. 20ms - 10s
External potentiometer adjustment voltage: 0-+5V
II. Terminal function introduction.
1、IN-: External power ground 0V
2, IN+: external power supply 10-50VDC, error less than 5%, the maximum voltage shall not exceed +60V DC. output current depends on the load, the maximum continuous current is 5A, short time acceleration maximum current is 10A.
3,4,5:MC,MB,MA:motor three phase
6, 7, 8: HC,HB,HA: motor Hall, input voltage range 0--+5V, low level 0 <= 0.8V high level 1>= 2.4V
9, V HALL: Hall power supply
Hall power supply voltage range: 7-12V DC, the maximum output current of 30mA (current-limited)
10, GND: Hall ground
11, EN: to ground prohibited, high or overhang effective
12, DIR: direction selection, connect +5V positive, ground reverse
13、BRAKE:Brake to ground
14, SEL: auxiliary selection, when the dip switch S1 reaches ON, the output +5V and the terminal 10 pin GND, 15 pin SV with the use.
15, SV IN: 0 -- +5V: external potentiometer/voltage analog input/frequency signal input, used with terminal's 10 pin GND, 14 pin SEL.
Three, potentiometer introduction.
P1 SPEED1: Speed 1 adjustment, clockwise increase, counterclockwise decrease.
P2 SPEED2/R: speed2/time ramp, please refer to the introduction of the ramp delay function.
P3 TORQUE :torque, maximum current limit value, linear adjustment of the maximum current range between 0-10A.
Packing:1PC
Warranty period: 120 days


On Mar 22, 2023 at 01:48:11 PDT, seller added the following information: