Description
 
HW-210K Dual-Channel VI Curve Tester Circuit Board Tester Online Detection w/ Four Test Frequencies

Description:

This handheld VI curve tester has 4 test frequencies. The portable tester can be used when connected to an oscilloscope. Both analogs oscilloscopes and digital oscilloscopes can be used. If you are looking for a circuit board tester, come and have a try, it will not let you down.

Features:
- With 4 test frequencies, it can be used when connected to an oscilloscope. Both analog and digital oscilloscopes are supported
- Dual signal input and alternating display enables easy operation
- 4 frequencies and adjustable AC speed
- Click to switch between single-channel and alternating display
- Made of plastic, it is durable to use
- Power supply: 24V DC (power adapter not included)

Oscilloscope Parameter Settings:
- Adjust your oscilloscope to X-Y mode (different oscilloscopes have different adjustment methods, please explore by yourself)
- Adjust the vertical parameters of the 2 channels of X Y to 1V/div, just adjust one mono oscilloscope
- Analog oscilloscopes do not need to adjust the time base, and digital oscilloscope time base is adjusted between 1-5ms
- When connected correctly, the oscilloscope will display a horizontal line. If a vertical line is displayed, the XY plug is reversed.
- Adjust vertical and horizontal parameters, and horizontal and vertical lines are located in the display box.

How to connect an analog oscilloscope?
- Connecting an analog oscilloscope is relatively simple, and it varies slightly from oscilloscope to oscilloscope.
- Adjust the oscilloscope to XY mode. Some oscilloscopes can be selected by pressing a button, while others can be selected via the XY mode knob. Please try it by yourself.
- Connect the BNC cable to the oscilloscope and power it on. Usually, a horizontal line will be displayed. Adjust the XY vertical channel parameters by about 1V/div, and then adjust the XY attenuation so that the horizontal line is in the display window. It can also pass the VI test version. The upper x-attenuation potentiometer can help adjust the length of the horizontal line. If the test lead is short-circuited, a vertical line will normally be displayed. If the vertical line is too long or too short, you need to adjust the Y channel parameter to make the vertical line appear in the display window. Half a grid or one grid on the edge is better. If the horizontal and vertical lines are normal, it can enter normal measurement values.

How to connect a digital oscilloscope?
- For digital oscilloscopes, enter XY mode via menus or keys. The two channels of XY are adjusted to 1V/div, and the monorail oscilloscope only needs to adjust the Y channel. Adjust the time base to 1-5 ms. The XY channel selects DC coupling and attenuates to 1x.
- When the oscilloscope is not connected, the screen should be a bright spot. Adjust the horizontal and vertical orientation to center the bright spot. Connect the VI tester. Usually, there should be a horizontal line. Adjust the 103 potentiometer at the top of the VI plate to form a horizontal line in the display box, and half a grid to the edge or 1 grid is a good short-circuit test lead. At this point the display should be a vertical line. Adjust the Y-channel parameters so that the vertical line is in the display box. So far, debugging is basically over.
- Do not charge it when testing boards online. If there is a large capacitor on the board, discharge the capacitor first, otherwise it is easy to burn the VI test board.

Package Included:
- 1 x Curve Tester
- 2 x BNC Cables
- 2 x Test Leads
Payment Terms
 
1. We accept PayPal,Payoneer,Visa Card,Google pay,Credit card etc.
2. We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay.
Shipping Terms
 
1. We will process the order within the handling time ,if you have any questions, please contact us via eBay message or email.
2. For remote regions of DHL/FedEx..., extra shipping costs might be charged. Usually it costs about 30USD-50USD. We will contact you if shipping company informed us your address belongs to remote area. Thanks for your understanding.
Return Terms
 
If you receive the item that not satisfied or defective, please do not open case and kindly notify us within 30 days. We will guide you the returning process for replacement or refund.
Custom Duties & Taxes
 
1. It is buyer's responsibility to cover the import duties, taxes.We do not charge any taxes and fees, and the possible taxes and fees will be collected by the platform or by third parties such as customs and carriers.
2. Please check with your country's customs office and inform us what/how much should declare before shipping.
Feedback
 
1. Please kindly leave us a positive feedback and 5 star DSR if you satisfied with our product and service. Please feel free to contact us firstly if you have any problem with your order, we are responsible and credible seller and will solve the issue it for you asap.
2. If you are dissatisfied for any reason, please don't be quick to leave us neutral or negative feedback. We work hard to make sure EVERY CUSTOMER 100% SATISFIED and resolve any problem for you and always leave positive feedback to all our customers.