Replace For Dixell XR06CX-4N1F1 Digital Thermostat Controller Fit Defrost Fans
XR06CX-4N1F1 Thermostat Controll

Replace For Dixell XR06CX-4N1F1 Digital Thermostat Controller Fit Defrost Fans 

Description:
High Quality Auto Parts Accessories
Free Fast Shipping From US warehouse
Free return if there is problem with product itself  within 30days(Exclude man-made damage)
Tested and Works before shipping.
Ready to use, Direct Replacement
Please check your part number or photos before purchasing.

(Note: Weekend information will be replied on the next working day)

The XR06CX, format 32x74x60 mm, is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. It has three relay outputs to control compressor, fan, and defrost, which can be either electrical or reverse cycle (hot gas). It is also provided with 2 NTC probe inputs, the first one for temperature control, the second one, to be located onto the evaporator, to control the defrost termination temperature and to managed the fan and it's provided with a configurable digital input. With the HOTKEY it's possible to program the instrument in a quick and easy way.
 
Suitable for appliances including
for applications on medium or low temperature ventilated refrigerating units

Replace Part Number: 
XR06CX-4N1F1 XR06CX4N1FI XR06CX 4N1FI
Professional Installation Is Highly Recommended.

Specification
Type: XR06CX-4N1F1
Mounting Measurements: 71mm x 29mm
Built-in Depth: 56mm
Supply: 110V
Voltage Type: AC
Probe Type: NTC (probes not included)
Number of Relay Outputs: 1
Relay Output 1: NO-20A(8)
Input: 1NTC
Kind of Protection: IP54
Version: Defrosting Function / Time Control
Measuring Range: -40°C up to +110°C
Display: 2½ Digit

With FC parameter it can be selected the fans functioning
• FC=cn will switch ON and OFF with the compressor and not run during defrost
• FC=on fans will run even if the compressor is off, and not run during defrost
After defrost, there is a timed fan delay allowing for drip time, set by means of the Fd
parameter.
• FC=cy fans will switch ON and OFF with the compressor and run during defrost
• FC=oY fans will run continuously also during defrost.
An additional parameter FS provides the setting of temperature, detected by the evaporator
probe, above which the fans are always OFF. This is used to make sure circulation of air only if
his temperature is lower than set in FS.

FANS AND DIGITAL INPUT
When the digital input is configured as door switch iF=do, fans and compressor status
depends on the dC parameter value:
dC=no normal regulation;
dC=Fn fans OFF;
dC=cP compressor OFF;
dC=Fc compressor and fans OFF.
When rd=y, the regulation restart with door open alarm

SAFETY PRECAUTIONS
• Check the supply voltage is correct before connecting the instrument.
• Do not expose to water or moisture: use the controller only within the operating limits avoiding
sudden temperature changes with high atmospheric humidity to prevent formation of
condensation.
• Warning: disconnect all electrical connections before any kind of maintenance.
• Fit the probe where it is not accessible by the End User. The instrument must not be opened.
• In case of failure or faulty operation send the instrument back to the distributor 
• Ensure that the wires for probes, loads and the power supply are separated and far enough
from each other, without crossing or intertwining.
• In case of applications in industrial environments, the use of mains filters (our mod. FT1) in
parallel with inductive loads could be useful.


Package included:
1 X Digital Thermostat Controller(as pictures show)

Note:
*Due to the Difference Between Different Monitors, the Pictures May Not Reflect the Actual Color of the Item.
*Please Check Part Photos and Part Description Above to Make Sure It Is What You Need? Compare the Part Number with Your Original One Before Purchasing.
*The Compatibility Chart Is for Reference Only, for Automotive Parts, Cross Checking the Part Number Is the Only Way to Make Sure Fitment!
*If You Have Any Problems After Purchasing, Please Contact Us in Time Before Opening Return or Case.
*We Will Not Pay for Your Installation Fee or Return Shipping Fee Caused by Incompatibility!
*But in Case You Aren't Satisfied the Item, Please Kindly Let Us Know, We Will Try Our Best to Solve It.

  Only PayPal at present.

*Your item will be carefully packed and shipped within 1 business day after payment received.

*Buyer requests express mail service or international shipping services, please contact us before ordering.

*Local pick-up is unavailable at the moment. 
 
* Item may be shipped from the eastern or western according to your address and item location.

Feedbacks are important not only to the seller but also buyer as well. If the transaction is to your liking, a positive feedback & 5star DSR is greatly appreciated.

We welcome honest feedbacks.

However, please do NOT leave any negative feedback before contacting us for resolution.
 
We not responsible for any customs duty/import tax, labor cost, expense in a dealer store, or damage due to wrong installation.