Item Description

Dear valued customer , 

this message is to explain that we are not on vacation , just we are suffering payment setting problem , can't accept order temporarily 。

we copied all the items to our another store to reduce the impact on you ,please visit here and make order : https://www.ebay.com/usr/ketech_electronic

we seek for a long term business , I sincerely hope that we can continue to cooperate in our another store . 

any problems , contact us freely .

regards,
gc_supermarket
 

Charging mode IN:
By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage is less than or equal to the lower limit voltage dn, the relay turns on and the charger starts charging the battery; when the battery voltage is more than or equal to the upper limit voltage UP, the relay disconnects to complete an automatic charging; when the relay turns on, IN flickers, indicating that it is charging.

Discharge mode OUT:
By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage is greater than or equal to the upper limit voltage UP, the relay turns on and starts discharging; when the battery voltage is less than or equal to the lower limit voltage dn, the relay turns off and completes an automatic discharging function; when the relay turns on, the OUT flickers, indicating that it is discharging.
Note: This product is a simple voltage controller. It can turn on and off the output by relay. It only plays the role of switching, and can not change the voltage.
Functional description:
1.Calculation of Voltage Percentage: Battery Voltage/(Upper Voltage-Lower Voltage)

2. Key function:
Short press UP button, switch display% and time, long press 5 seconds switch mode, charging mode: IN, discharge mode: OUT
SET key: Short Click to view the parameters currently set;
Long press SET button to enter the parameter setting interface, set UP: voltage upper limit, dn: voltage lower limit, OP: turn-on time, dOP: delay turn-on time (0-999 seconds), FOP: forced turn-on time (0-10 seconds) in discharge mode.
Short press DOWN button, turn off/turn on relay enable (emergency stop function) turn off, LCD display OFF, relay disconnect
Long press DOWN button to set the status of LCD backlight L-P: OFF backlight constant brightness, ON: backlight automatically extinguishes after 5-10 minutes; after extinguishing, any key wakes up.

3. Parameter Settings
(a) Enter the parameter setting interface by pressing the SET key for a long time;
B) After entering the parameter setting interface, switch the setting parameters by pressing the SET key.
C) After choosing parameters, it can be set by UP/DOWN key to support short press and long press.
D) To set other parameters, repeat steps B and c;
E) After all parameters are set, press SET key for a long time, exit and save;

3.1 Charging/Discharging Time Control Function
When the time parameter OP is non-zero, start charging/discharging time control.
When the relay turns on a charge/discharge, the countdown begins; when the time is completed, the relay is automatically disconnected to complete a charge/discharge process; if the time is completed, in the charging mode, the detection voltage is less than the lower limit voltage dn or in the discharge mode, the detection voltage is more than the upper limit voltage UP, and the charging time control function is automatically turned off and flashes. Indicate H: ER reminds users that time parameter setting is unreasonable; press any key to stop flickering;
When the charging/discharging time control is not turned on, the product will record a complete time. When entering the time display interface, flashing shows the charging time, then exiting the time display interface or clearing the next time the charging is turned on (relay is turned on).

3.2 Automatic parameter detection:
When the parameters are set and exit, if the lower voltage limit DN is greater than the upper voltage up, the system will flicker to display "ERR" as a reminder.

3.3 Delayed turn-on function (0-999 seconds): completion of a charge/discharge, the interval between re-opening;

3.4 Discharge Conduction Forced Start Time (0-10S): After satisfying the relay conduction condition, the relay is forced to turn on (0-10S) to detect the battery voltage again. This function is mainly aimed at discharging function. Some test loads will pull down the lower limit voltage instantaneously at the moment of conduction, which will lead to the disconnection of the relay and the failure of normal discharge process.

Package Included:
1X Battery Charging Control Module

We appreciate positive feedback . we always try our best to service our customers .
  so if you have ant question ,PLEASE DON’T HESITATE TO TELL US,
  we are always here to offer help .

We prefer PayPal .For purchasing multiple items , please contact us for a combined invoice .

generally we would like to receive payment thin 48 hours if .

 

We provide airmail service with good package . The items will be shipped within the nest

2 business days after we received the payment . when you buy multiple items ,your shipping

cost will be combined with discount .

SHIPPING TIME (weekends/holidays excluded)

   
   

Country Name

Shipping Time

Country Name

Shipping Time

   

USA/Canada

10 -15d

Spanish/Portugue

10-25d

   

East/South Asia

10 -15d

France/West Asia

10-25d

   

United Kingdom

10 -20d

Italy

10-30d

   

Australia/New Zealand

10 -15d

West Asia/Middle East

15-25d

   

Most Country of West/North Europe

10-20d

South America and Africa

15-30d

   

East /Middle Europe/Russia

10-25d

     

 

  • NEW, GOOD QUALITY, ORIGINAL PACKAGE
  • LARGE STORE AND THE LOWEST PRICE
  • NO-QUESTION-REFUND,
  •             FOR LARGE QUANTITY ,OFFER BETTER PRICE,ORIGINAL      
     PACKING(TAPE REEL/TUBE/TRAY)
     

We specialize in electronic components . ICs, Capacitors, Diodes, Resistors, LEDs,

Transistors, and so on. Especially in Hard To Find Parts . we only sell

NEW , ORIGINAL parts . please buy with confidence .We offer NO-QUESTION-REFUND

 

DataCaciques