High-accuracy DC/AC Voltage Current Resistance Tester Digital Multimeter Meter 



Introduction:

Features:

  • 21,000/51,000-count display
  • Large-screen dual-display VFD with high brightness
  • True RMS AC voltage and current measurements, bandwidth up to 100kHz
  • Measurement functions, including DCV/ACV, DCI/ACI, Ω, frequency/period, diode, Continuity, dBm, dB, etc.
  • Parameters,such as AC+DC, AC+Hz, Readout+d B, Readout+dBm, displayed synchronously
  • Measurement speed up to 25 meas/sec
  • DCV accuracy up to 0.02%, resolution up to 10µV
  • Measured value displayed in the form of percentage
  • Relative mode (REL) to eliminate residual reading
  • Calibration without opening the case
  • Limit function (HI/IN/LO) for fast sorting
  • Equipped RS232C (optional) communication interface providing convenient system communication

Specifications:

Measurement condition

 

Measurement
Parameters

DC/AC Voltage,DC/AC Current,Resistance,Frequency,Period,Continuity,Diode

Math function

%, dB, dBm, REL

Range

Auto,Manual

Display

VFD,dual display

Trigger mode

INT/MAN/BUS

Reading hold

TO find out the best stable reading for each data block of the given reading number according to given accuracy

Comparator

To judge HI,IN,LO and display,with ALARM at HI/LO(selectable)

Interface

USB,SCPI,RS232C (Option)

Performance parameters

Uncertainty expression: ± (% of reading +% of full scale)

Speed (counts/second)

Speed

Slow

Middle

Fast

DCV,DCI

5

10

25

ACV,ACI

5

10

25

Ω

5

10

25

AC+DC

1.2

1.4

1.5

Freq

1

2

3.9

DC Voltage

Range

Resolution

Maximum uncertainty (1 year)

500mV-1000V

10uV

0.02%+0.008%

DC Voltage Current

Range

Resolution

Maximum uncertainty (1 year)

5mA-20A

100nA

0.05%+0.008%

AC Voltage

Bandwidth

Range

Resolution

Maximum uncertainty (1 year)

20Hz-100kHz

500mV-750V

10uV

0.35%+0.02%

AC Current

Bandwidth

Range

Resolution

Maximum uncertainty (1 year)

20Hz-10kHz

5mA-20A

100nA

0.5%+0.08%

Resistance

Range

Test current

Resolution

Maximum uncertainty (1 year)

500Ω-50MΩ

45nA-0.5mA

10mΩ

0.1%+0.008%

Frequency

Range

Sensitivity

Resolution

Maximum uncertainty (1 year)

5Hz-1MHz

200mVrms

0.0001Hz

0.01%+0.008%



DataCaciques