High Low Voltage AC Current Meter Ammeter Digital Clamp Current Tester 0mA~1200A

Note: Battery not Included During The Shipping !!!


Function:

Digital Multimeter Clamp Meter H/L Voltage Clamp Current Meter it can be used for current measurement and online current measurement of lines with insulation below 60kV or high-voltage lines with bare conductors below 35kV. Used in substations, power plants, industrial and mining enterprises

Features:

1. Using CT technology and mask digital integration technology, the instrument is composed of a special clamp-type ammeter and a high-voltage insulating rod. If the insulating rod is not used, it can also be used as a high-precision low-voltage clamp ammeter. 

2. It can be used for current measurement and online current measurement of lines with insulation skin below 60kV or high-voltage lines with bare wires below 35kV.

3. With peak hold, data hold, data storage.

4. Its special clamp-type ammeter can easily clamp or evacuate the tested wire by pulling down or pushing the insulating rod forward, saving time and speed.

Specifications:

Range

0.00mA~1200A (50/60Hz automatic)

Resolution

1mA

Current Accuracy (23℃±3℃, below 80%RH)

0mA~100A: ±1%±5dgt

100A~599A: ±1.5%±5dgt

600A~1200A: ±2%±5dgt

Power Supply

6V DC LR03 (1.5V AAA ×4 alkaline dry batteries) 

(Battery are not included)

Weight

Detector: 620g (with battery), the total weight of meter: 3720g (including insulation rod and battery)

Dimension

Tester: 218mm×135mm×60mm

Clamp Dimension

68mm

Insulation Rod Dimension

dia 32mm 1m×5 piece

LCD Dimension

47 mm×28.5mm

Sampling Rate

2 times/s

PEAK Hold

Automatically maintain the height of the test value, usually in the test mode press PEAK key, LCD top right corner will display “
PE”, that is, to keep open the PEAK function, then press PEAK key to cancel this function

Data Hold

In usual testing mode, press HOLD key to keep data, shown by “HOLD”

Data Memory

99 sets, memory process is shown by MEM , full storage is shown by blinking “FULL”

Data Access

“MR” indication, can access to all data

Overflow Display

Over-range overflow function: shown in “OL A”

Automatic Shutdown

15 minutes after boot

Battery Voltage

When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement

External Disturbance

Without 315MHz and 433 MHz interference

Structure

Anti-drip type II




On Jan 3, 2023 at 23:53:53 PST, seller added the following information:

DataCaciques