Low Voltage CT Turn Transformation Ratio Tester Leakage Current Test Transformer

Note: Battery not Included During The Shipping !!!

 

Introduction:

  • Low-voltage CT ratio tester can be widely used in 380/220-volt power system, which can easily and quickly realize online on-site testing of current transformers in metering devices and determination of current and leakage current values in 380/220-volt power system, realizing accurate testing of current transformer ratio, angle difference, phase difference and polarity in actual operation without power outage. 
  • The tester is composed of mainframe, primary flexible current clamp and secondary current clamp. The diameter of the flexible current clamp is 8mm, which is especially suitable for narrow space and dense lineup of testing places.

Features:

  • Low-voltage current transformer a secondary circuit of current, ratio, angle difference test, polarity, phase difference judgment
  • Ratio measurement range: 19999
  • Variable ratio resolution: 0.1
  • Primary current clamp
  • Range: 0.0A ~ 3000A; Resolution: 0.1A; Accuracy: ±1%FS
  • Secondary current clamp
  • Range: 0.00mA5A; Resolution: 0.01mA; Accuracy: ±0.5%FS
  • Primary current clamp jaw size: Φ200mm
  • Secondary current clamp jaw size: Φ8mm

Specification:

Function

Range

Accuracy

Resolution

Variable Ratio

19999

——

0.1

Angle difference

0360°

±3°

1°

Primary current

0.0A3000A

±1%FS

0.1A

 

 

 

 

Secondary current

0.00mA5A

±0.5%FS

0.01mA


  • Primary current clamp connection mode: wired connection, line length 2m
  • Primary current clamp size: CT size: Φ200mm; external size: 200mm×245mm×13mm
  • Secondary current clamp size: CT size: Φ8mm; external dimension: 137mm×40mm×19.5mm
  • Mainframe dimension: 78mm×165mm×42mm
  • Instrument mass: about 600g
  • Battery specification: 7 # alkaline dry battery (1.5V × 4)not included, continuous use of about 30 hours
  • Storage data: 3000 groups
  • Sampling rate: 3 times / second
  • Automatic shutdown: about 15 minutes
  • Battery voltage: When the battery voltage is lower than 4.8V, remind to replace the battery 
  • Overflow display: Over-range overflow function: "OL A" symbol display
  • Current clamp lead : Length : 2m
  • Operating temperature and humidity : -15℃50℃below 70%RH
  • Storage temperature and humidity : -15℃60℃less than 70%RH
  • Dielectric strength: AC3700V/rms between the clamp core and the shell

 