SEIMENS 3RV2011-1BA15 CIRCUIT BREAKER 4-2, 0A 1NO+1NC NEW WITH BOX.


Circuit breaker size S00 for motor protection, CLASS 10 A-release 1.4...2 A N-release 26 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC

product brand name SIRIUS

product designation Circuit breaker

design of the product For motor protection

product type designation 3RV2

General technical data

size of the circuit-breaker S00

size of contactor can be combined company-specific S00, S0

product extension auxiliary switch Yes

power loss [W] for rated value of the current

● at AC in hot operating state 7.25 W

● at AC in hot operating state per pole 2.4 W

insulation voltage with degree of pollution 3 at AC rated value 690 V

surge voltage resistance rated value 6 kV

maximum permissible voltage for safe isolation in networks with grounded star point

● between main and auxiliary circuit 400 V

● between main and auxiliary circuit 400 V

shock resistance according to IEC 60068-2-27 25g / 11 ms

mechanical service life (switching cycles)

● of the main contacts typical 100 000

● of auxiliary contacts typical 100 000

electrical endurance (switching cycles) typical 100 000

type of protection according to ATEX directive 2014/34/EU Ex II (2) GD

certificate of suitability according to ATEX directive 2014/34/EU DMT 02 ATEX F 001

reference code according to IEC 81346-2 Q

Substance Prohibitance (Date) 10/01/2009

Ambient conditions

installation altitude at height above sea level maximum 2 000 m

ambient temperature

● during operation -20 ... +60 °C

● during storage -50 ... +80 °C

● during transport -50 ... +80 °C

temperature compensation -20 ... +60 °C

relative humidity during operation 10 ... 95 %

Main circuit

number of poles for main current circuit 3

adjustable current response value current of the current-dependent overload release 1.4 ... 2 A

operating voltage

● rated value 690 V

● rated value 20 ... 690 V

● at AC-3 rated value maximum 690 V

operating frequency rated value 50 ... 60 Hz

operational current rated value 2 A

operational current

● at AC-3 at 400 V rated value 2 A

operating power

● at AC-3

— at 230 V rated value 0.4 kW

— at 400 V rated value 0.8 kW

— at 500 V rated value 0.8 kW

— at 690 V rated value 1.1 kW

operating frequency

● at AC-3 maximum 15 1/h

Auxiliary circuit

design of the auxiliary switch transverse

number of NC contacts for auxiliary contacts 1

number of NO contacts for auxiliary contacts 1

number of CO contacts for auxiliary contacts 0

operational current of auxiliary contacts at AC-15

● at 24 V 2 A

● at 120 V 0.5 A

● at 125 V 0.5 A

● at 230 V 0.5 A

operational current of auxiliary contacts at DC-13

● at 24 V 1 A

● at 60 V 0.15 A

Protective and monitoring functions

product function

● ground fault detection No

● phase failure detection Yes

trip class CLASS 10

design of the overload release thermal

breaking capacity operating short-circuit current (Ics) at AC

● at 240 V rated value 100 kA

● at 400 V rated value 100 kA

● at 500 V rated value 100 kA

● at 690 V rated value 10 kA

breaking capacity maximum short-circuit current (Icu)

● at AC at 240 V rated value 100 kA

● at AC at 400 V rated value 100 kA

● at AC at 500 V rated value 100 kA

● at AC at 690 V rated value 10 kA

response value current of instantaneous short-circuit trip unit 26 A

UL/CSA ratings

full-load current (FLA) for 3-phase AC motor

● at 480 V rated value 2 A

● at 600 V rated value 2 A

yielded mechanical performance [hp]

● for single-phase AC motor

— at 230 V rated value 0.13 hp

● for 3-phase AC motor

— at 460/480 V rated value 1 hp

— at 575/600 V rated value 1 hp

contact rating of auxiliary contacts according to UL C300 / R300

Short-circuit protection

product function short circuit protection Yes

design of the short-circuit trip magnetic

design of the fuse link

● for short-circuit protection of the auxiliary switch required Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)

design of the fuse link for IT network for short-circuit protection of the main circuit

● at 400 V gL/gG 25 A

● at 500 V gL/gG 25 A

● at 690 V gL/gG 20 A

Installation/ mounting/ dimensions

mounting position any

fastening method screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715

height 97 mm

width 45 mm

depth 97 mm

required spacing

● for grounded parts at 400 V

— downwards 30 mm

— upwards 30 mm

— at the side 9 mm

● for live parts at 400 V

— downwards 30 mm

— upwards 30 mm

— at the side 9 mm

● for grounded parts at 500 V

— downwards 30 mm

— upwards 30 mm

— at the side 9 mm

● for live parts at 500 V

— downwards 30 mm

— upwards 30 mm

— at the side 9 mm

● for grounded parts at 690 V

— downwards 50 mm

— upwards 50 mm

— backwards 0 mm

— at the side 30 mm

— forwards 0 mm

● for live parts at 690 V

— downwards 50 mm

— upwards 50 mm

— backwards 0 mm

— at the side 30 mm

— forwards 0 mm

Connections/ Terminals

product component removable terminal for auxiliary and control circuit No

type of electrical connection

● for main current circuit screw-type terminals

● for auxiliary and control circuit screw-type terminals

arrangement of electrical connectors for main current circuit Top and bottom

type of connectable conductor cross-sections

● for main contacts

— solid or stranded 2x (0,75 ... 2,5 mm²), 2x 4 mm²

— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

● at AWG cables for main contacts 2x (18 ... 14), 2x 12

type of connectable conductor cross-sections

● for auxiliary contacts

— solid or stranded 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

● at AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14)

tightening torque

● for main contacts with screw-type terminals 0.8 ... 1.2 N·m

● for auxiliary contacts with screw-type terminals 0.8 ... 1.2 N·m

design of screwdriver shaft Diameter 5 to 6 mm

size of the screwdriver tip Pozidriv size 2

design of the thread of the connection screw

● for main contacts M3

● of the auxiliary and control contacts M3

Safety related data

B10 value

● with high demand rate according to SN 31920 5 000

proportion of dangerous failures

● with low demand rate according to SN 31920 50 %

● with high demand rate according to SN 31920 50 %

failure rate [FIT]

● with low demand rate according to SN 31920 50 FIT

protection class IP on the front according to IEC 60529 IP20

touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front

display version for switching status Handle

Certificates/ approvals