SERIOUS BUYERS ONLY!
PLEASE READ STORE DETAILS CAREFULLY!
 

 

 

*** BRAND NEW ***

FLUKE 1587/ I400 FC 1587FC 2IN1 INSULATION MULTIMETER W FLUKE CONNECT WITH I400 CURRENT CLAMP

Item Details:

Manufacturer: FLUKE

Description from Manufacturer:

 

 

 

Product overview: Fluke 1587 FC Advanced Electrical Troubleshooting Kit

The products in this kit have been specifically selected for both troubleshooting and preventative maintenance applications.

Includes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp

The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app:

  • Pi/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
  • Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
  • Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
  • Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets

The Fluke i400 AC CurrentClamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.

 

Product highlights

  • PI/DAR timed ratio tests
  • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
  • VFD low-pass filter for accurate motor drive measurements
  • Auto-discharge of capacitive voltage for added user protection
  • Insulation test (1587 FC: 0.01 M? to 2 G?)
  • Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V) for many applications
  • AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (?), Continuity
  • Capacitance, diode test, temperature, Min/Max, frequency (Hz)
  • Auto power off to save battery power
  • CAT III 1000 V, CAT IV 600 V measurement category
  • Large display with backlight
  • Rugged, utility hard case allows you to bring everything you need for the job
  • Included accessories: Remote probe, test leads and probes, alligator clips, K-type thermocouple
  • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient hands free operation
  • Three-year standard warranty;

Features:

  • PI/DAR measurements with TrendIt™ graphs
  • Memory storage through Fluke Connect Measurements app
  • Temperature Compensation through Fluke Connect Measurements app
  • VFD low-pass filter for accurate motor drive measurements
  • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation test: 0.01 M? to 2.0 G?
  • Auto-discharge of capacitive voltage
  • Insulation test smoothing reading
  • Frequency
  • Capacitance
  • Diode test
  • Temperature
  • Min/Max
  • AC/DC Voltage
  • DC Millivolts
  • AC/DC Milliamps
  • Resistance (0.1 ? to 50 M?)
  • Continuity
  • Three-year warranty
  • Remote probe, test leads, alligator clips
  • K-type thermocouple
  • Rugged, utility hard case
  • Auto power off

Sepcifications:

Fluke 1587 FC Insulation Multimeter

Electrical Specifications
AC voltage measurement
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
6.000 Vi Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage 
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
DC Voltage Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
6.000 V dc 0.001 V ±(0.09% + 2)
60.00 V dc 0.01 V ±(0.09% + 2)
600.0 V dc 0.1 V ±(0.09% + 2)
1000 V dc 1 V ±(0.09% + 2)
Input impedance  10 MO (nominal), <100 pF
Normal mode rejection ratio  >60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio  >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
600.0 mVdc 0.1 mV ±(0.1% + 1)
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
Range 60 mA 
Resolution 0.01 mA 
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor =1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
¹ 1 kHz bandwidth
Ohms Measurement
Range Resolution Accuracy +(% of Rdg+Counts)¹
600.0 O 0.1 O ±(0.9% + 2)
6.000 kO 0.001 kO ±(0.9% + 2)
60.00 kO 0.01 kO ±(0.9% + 2)
600.0 kO 0.1 KO ±(0.9% + 2)
6.000 MO 0.001 MO ±(0.9% + 2)
50.0 MO ² 0.01 MO ±(1.5% + 3)
Overload protection  1000 V rms or dc
Open circuit test voltage  <8.0 V dc
Short circuit current  <1.1 mA
¹ Accuracies apply from 0% to 100% of range
² Up to 80% relative humidity
Diode Test
Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current:
Accuracy ±(2% + 3)
Continuity Test
Continuity indication Continuous audible tone for testresistance below 25 O and off above 100 O. Maximum Reading; 1000 O
Open circuit voltage <8.0 V
Short circuit current 1.0 mA typical
Overload protection 1000 V rms
Response time >1 m sec
Frequency Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)
99.99 Hz  0.01 Hz  ±(0.1% + 1)
999.9 Hz  0.1 Hz  ±(0.1% + 1)
9.999 kHz  0.001 kHz  ±(0.1% + 1)
99.99 kHz  0.01 kHz  ±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV ac  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  100.0 mV 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 150.0 mV 
DC Trigger Levels¹ to 20 kHz² NA
6.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  1.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 1.5 V 
DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V
60.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  10.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 36.0 V 
DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V
600.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  100.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
1000.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  300.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
² Usable to 100 kHz with full scale input
Capacitance
Range  Resolution  Accuracy ±(% of Rdg+Counts)
1000 nF  1 nF ±(1.2% + 2)
10.00 µF  0.01 µF ±(1.2% + 2)
100.0 µF  0.1 µF ±(1.2% ±90 counts)
9999 µF  1 µF ±(1.2% ±90 counts)
Temperature Measurement
Range  Resolution  Accuracy ±(% of Rdg+Counts)¹
-40 ° C to 537 ° C  0.1 °C  ±(1% + 10 counts)
-40 ° F to 998 ° F  0.1 °F  ±(1% + 18 counts)
¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
Insulation Specifications
Measurement range 0.01 MO to 2 GO
Test voltages 50, 100, 250, 500, 1000 V
Test voltage accuracy +20%, -0%
Short-circuit test current 1 mA nominal
Auto discharge Discharge time <0.5 second for C = 1 µF or less
Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load Operable with up to 1 µF load
Output Voltage
50 V (0% to +20%) Display range 0.01 to 6.00 MO
Resolution 0.01 MO
Test current 1 mA @ 50 kO
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 50.0 MO
Resolution 0.1 MO
Test current 1 mA @ 50 kO
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
100 V (0% to +20%) Display range 0.01 to 6.00 MO
Resolution 0.01 MO
Test current 1 mA @ 100 kO
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 60.0 MO
Resolution 0.1 MO
Test current 1 mA @ 100 kO
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 60 to 100 MO 
Resolution 1 MO
Test current 1 mA @ 100 kO
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
250 V (0% to +20%) Display range 0.1 to 60.0 MO 
Resolution 0.1 MO
Test current 1 mA @ 250 kO 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 250 MO 
Resolution 1 MO
Test current 1 mA @ 250 kO 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
500 V (0% to +20%) Display range 0.1 to 60.0 MO
Resolution 0.1 MO
Test current 1 mA @ 500 kO 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 500 MO
Resolution 1 MO
Test current 1 mA @ 500 kO 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range 0.1 to 60.0 MO 
Resolution 0.1 MO
Test current 1 mA @ 1 MO
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 600 MO 
Resolution 1 MO
Test current 1 mA @ 1 MO
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 0.6 to 2.0 GO 
Resolution 100 MO 
Test current 1 mA @ 1 MO
Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts)
General Specifications
Maximum voltage applied to any terminal and common 1000 V
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
Relative humidity Noncondensing
0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Radio frequency communication 2.4 GHz ISM Band
Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
Electromagnetic Compatibility 
International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Enclosure protection IEC 60529: IP40 (non-operating)
Safety
IEC 61010-1 Pollution Degree 2
IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V
Batteries  Four AA batteries (NEDA 15A or IEC LR6)
Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MO with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight 550 g (1.2 lb)
Altitude Operating 2000 m
Storage 12,000 m
Over-range capability 110% of range except for capacitance which is 100%
Frequency overload protection <107 V Hz
Fuse protection for mA input 0.44A, 1000 V, IR 10 kA
 

Fluke i400 AC Current Clamp

Specifications
Nominal current range 400 A
Continuous current range 1 A - 400 A
Maximum non-destructive current 1000 A
Lowest measurable current 1 A
Basic accuracy 2% + 0.06 A
(45-400 Hz)
(% reading + floorspec)
Useable frequency 5 Hz - 20 kHz
Output level(s) 1 mA/A
Safety Specifications
Safety CAT IV 600 V, CAT III, 1000 V
Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010
Mechanical and General Specifications
Warranty 1 year
Maximum conductor diameter 32 mm (1.25 in)
Maximum conductor size (busbar) 750 MCM
Output cable length 1.5 m (59 in)
Shrouded banana plugs Yes
    

Includes:

  • Fluke 1587 FC 2-in-1 Insulation DMM
  • Fluke i400 Current Clamp
  • Test leads
  • Alligator clips
  • K-type thermocouple
  • Hard case
  • User documentation
Condition: NEW

Auction Details:

Shipping:
  • All domestic packages will be shipped out via Fedex, UPS, or USPS within the lower 48 states
  • Free shipping is through the most economic option

  • Shipping to Hawaii Puerto Rico Alaska costs extra, email us for shipping quote and those shipments will be shipped out via USPS priority mail, unless otherwise stated in the auction or negotiated in emails.
  • Shipping to APO, RR, or PO box will be handled via USPS and would be extra on certain items, please email us prior bidding.
  • Goods will be dispatched the latest in 2 business days.
  • Goods will be shipped out after the holidays and weekends.
  • No local pick ups accepted at this time, unless otherwise stated in the auction
  • We ship to any destination in the world.
  • INTERNATIONAL BUYERS: The International shipping rate is flat rate to most destinations in the world, please email us for additional information.
  • International  buyers are responsible for all tax and custom duty charges outside the country.
Payment:
  • U.S. Buyers: Credit cards through PayPal
  • Please note that we can't accept direct credit card payments at this time
  • International Buyers: PayPal or Wire
  • Payment is due within 6 days of auction closing. If payment is not received within this time unless otherwise stated or negotiated, item will be relisted on eBay.
Terms & Conditions:
  • After the auction is closed, auction winners should contact us regarding any questions or requests.
  • After the auction is closed, payment should be received within 6 days.
  • Buyer has 30 days to return the product, return product should be brand new with all original accessories, buyer pays shipping costs.
  • Shipping and handling charges are not returnable
  • Items will be replaced or exchanged in case of DOA
  • If the same item or similar item is not in stock in case of DOA, the buyer will receive a refund back
  • We combine shipping to save customers money, however, there will be an additional charge per item, please read the description for each item to find out about the specific fees.
  • All buyers are subject to pay all taxes and duty fees inside and outside of the United States,
  • Our facilities are closed during the weekends and other holidays and there will be no shipments during these time periods. All packages will go out after the weekend or after the holidays.
Contact Information: Please use ebay message