CENTER-384 Track Gas Leak Detector 5% Hydrogen (H2) + 95% Nitrogen (N)

 

 

CENTER-384 Track Gas Leak Detector can detector mixture 5% Hydrogen (H2) + 95% Nitrogen (N) with extremely sensitivity. The unit is built in newly developed heated semi-conductor sensor and microprocessor control to provide reliable digital signal processing. Adjustable leak sensitivity leavel and 7 LED visual indicators also offer the users the ease and convenience of operations. It can detect less than 5 ppm Hydrogen concentraton.
 
CENTER-384 gas leak detector can detect 5% hydrogen (hydrogen) + 95% nitrogen (nitrogen) mixed gas, mainly used in the installation of air conditioners or used in the detection of cooling systems of compressors. The product has high sensitivity. Using newly developed semiconductor sensors, microprocessor control provides reliable digital signal processing. High and low adjustable leakage sensitivity selection, 7 light-emitting LED visual indicators also provide users with convenient operation
specifications Detectable Gases: mixture 5% Hydrogen (H2) + 95% Nitrogen (N)
Sensitivity: Less than 5ppm; 2g/year
Alarm Method: Buzzer alarm, LED bar Indicator
Detection Tube Length: 15.5 inch (390mm)
Warm-Up Time: 45 sec.
Battery: 1.5V AA x 4
Dimension: 173 x 66 x 56 mm
Weight: 400g
Advantages 1. Microprocessor control with advanced digital signal processing
2. Multi color visual display
3. High-median-Low leak sensitivity selector
4. Low battery indication
5. Semiconductor gas sensor
6. Detection of Hydrogen
7. 15.5 (39cm) flexible stainless probe
8. Ambient concentration reset