3 Phase Power Analyzer 3 Phase Power Quality Analyzer Meter Power Energy Meter
Features:
ETCR5000 Power Quality Analyzer's Basic Function:
1. Transient capture function
2. Starting current monitoring
3. Trend chart recording and storing function
4. Alarm function
5. Snapshot function
6. Communication function
7. Setting function
8. Help menu in Chinese/English
Specification:
Power Supply | Rechargeable lithium battery pack 9.6V, external charger. |
Battery indicator | Battery symbol 5 grid Show the power, when the battery power is too low, prompted 1 minutes after the automatic shutdown. |
Working current | Current 490mA, the battery is full of electricity for about 8 hours of continuous work. |
display mode | LCD Color screen, 640dots * 480dots, 5.6 inch display domain 116mm * 88mm. |
Clamp size | 008B: φ8mm; 040B: φ40mm; 068B: φ68mm; 300F: φ300mm |
Instrument size | 240mm*170mm*68 mm. |
Total Weight | 6KG |
Channel number | 4-CH voltage, 4-CH current. |
Line voltage | 1.0V~2000V. |
Phase voltage | 1.0V~1000V. |
Electric current | 008B/040B/068B/300F Current clamp |
frequency | 40Hz~70Hz. |
Electric quantity parameter | W, VA, Var, PF, DPF, cosφ, Tanφ |
Electric energy parameters | Wh, Varh, Vah. |
Harmonic | Yes, 0~50 times. |
Total harmonic distortion | Yes, 0~50 times, each phase. |
Expert mode | Yes. |
Transient recording | 150 Groups. |
Voltage flicker | Yes. |
Starting current mode | Yes, 100 seconds. |
Three-phase unbalance degree | Yes. |
Record | 300Day (record 20 parameters simultaneously, 1 points per 5 seconds). |
Min / Max Record value | There are, can be measured for a period of time the maximum and minimum value. |
Give an alarm | 40Different types of parameter selection, 12800 groups of alarm log. |
Peak value | Yes |
Phasor diagram display | Automatically. |
Screenshot capacity | 60A. |
Menu language | English and chinese. |
communication interface | USB |
Automatic shutdown | In the alarm / trend chart recording / transient capture mode (waiting or in the middle), the instrument does not automatically shut down. |
In other test mode, no button operation within 15 minutes, 1 minutes after the automatic shutdown. | |
Backlight function | There is, for the dark places and at night. |
Voltage test line | 3m |
Current clamp length | 2m |
Working temperature and humidity | -10C~ 40 degrees C; 80%Rh below. |
Storage temperature and humidity | -10C~ 60 degrees C; 70%Rh below. |
Input impedance | The input impedance of the test voltage is 1M. |
Pressure | The instrument circuit and the outer shell withstand 3700V/50Hz sine wave alternating current voltage for 1 minutes. |
insulation | Between the instrument line and the jacket shell is larger than 10M. |
structure | Double insulation with anti-insulation vibration jacket. |
Safely Standard | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2. |
Accessories | Host: 1PCS; Instrument Bag: 1pcs; Test Cable: 5PCS (yellow, green, red, blue, black); Alligator Clip: 5PCS; Probe: 5PCS; Charger 1PCS; Software CD: 1COPY; Optional Current Clamp: 4PCS |
Parameters of current clamps:
Model | 008B | 040B | 068B | 300F |
Function | AC current and leakage detection | |||
Test model | Clamp CT, Current induction output | |||
Clamp size | Φ8mm | Φ40mm | Φ68mm | Φ300mm |
Current range | AC 10mA~10.0A | AC 0.1A~100A | AC1.0A~1000A | AC10A~6000A |
Resolution | 0.1mA | |||
Accuracy | 0.5% (23℃±3℃, below 70%RH) | |||
Current transform | Around 1A/1mA | |||
Circuit voltage | Lower than AC600V | |||
Cable length | 2m | |||
Working environment | -20℃~50℃; below 80%RH | |||
Storage environment | -10℃~60℃; below 70%RH | |||
Weight | 170gX4 | 190gX4 | 510gX4 | |
Package:
· 1x ETCR5000 Power Quality Analyzer
· 4x Current Clamps (4 types Optional)
· 5x Test Cable (yellow, green, red, blue, black)
· 5x Alligator Clip
· 5x Probes
· 1x Charger
· 1x Software CD
· 1x Instrument Bag