2 x 6BM8/ECL82 Telefunken Tubes 

Made in West Germany

<> on bottom

The lettering is smudged/missing


Tested on enhanced Triplet E3444 laboratory Tester prepared by Paul Hart of Roswell Ga.

6600/2100 micromhos @ 36/3.1 mA
7300/2100 micromhos @ 43/3.1 mA 

Bogey(100% or New) = 6400/2500 micromhos @ 35.00/3.5 mA +/- 10%

I do combine S&H


The measurements in this listing were taken on a Triplett 3444 modified to test the tube as an amplifier in accordance with RMA/EIA specifications, utilized by all US and most foreign tube manufacturers.  This tester applies test conditions for this tube as shown below (including the precise filament voltage) and then measures transconductance (gm) in accordance with the engineering definition of gm. Tubes may also be operated under the test conditions for extended periods to be sure that it is stable.  A tube must be tested in this manner to compare its test results with the manufacturer’s original intent or with other tubes of the same type. Most tube testers do not apply the test conditions required or conduct a valid gm test. For more details on the test and our test equipment, please contact us.

The test conditions for this listing are

__200_Volts plate, __200_Volts screen, ___-16.0___Volts bias or Cathode resistance*

__100_Volts plate for 2nd section

What were your tubes tested at?

I do combine shipping