4 x 6SN7gtb Sylvania Tubes

Made in USA 

Black plates

Tall Boy

Matching production codes(K5M) on all  1955 at the Emporium Pa. plant

Matching Warranty codes on base - 944-639

***The auction is for 4 tubes ***


Tested on Enhanced Triplet E3444 Laboratory Tester

Results
=
2450/2430 micromhos @ 6.5/6.3 mA
2320/2210 micromhos @ 5.9/5.1 mA
2420/2380 micromhos @ 6.3/6.1 mA
2350/2300 micromhos @ 5.7/5.5 mA

Bogey (100% or New) = 2600/2600 micromhos @ 9.0/9.0 mA +/- 10%


The measurements in this listing were taken on a Triplett 3444 modified to test the tube as an amplifier in accordance with RMA/EIA specifications, utilized by all US and most foreign tube manufacturers.  This tester applies test conditions for this tube as shown below (including the precise filament voltage) and then measures transconductance (gm) in accordance with the engineering definition of gm. Tubes may also be operated under the test conditions for extended periods to be sure that it is stable.  A tube must be tested in this manner to compare its test results with the manufacturer’s original intent or with other tubes of the same type. Most tube testers do not apply the test conditions required or conduct a valid gm test. For more details on the test and our test equipment, please contact us.

The test conditions for this listing are

__250_Volts plate, __250_Volts screen, ___-8.0___Volts bias or Cathode resistance

What were your tubes tested?

I do combine S&H