Dental Core Tool For Nobel NP/RP Conical Attachment Abutment Lab Male Caps

Model:

● Locater Core Tool
● Male Cap kit :1 Metal Housing+ 4 Retentive caps (Extra Soft + Soft + Standard + Lab Use)
● Locater Core Tool & Male Caps KIT
● NP 3mm Abutment & Male Caps KIT
● NP 4mm Abutment & Male Caps KIT
● NP 5mm Abutment & Male Caps KIT
● RP 3mm Abutment & Male Caps KIT
● RP 4mm Abutment & Male Caps KIT
● RP 5mm Abutment & Male Caps KIT
 
Product Description:

● Implant System Compatible With:  NOBEL Biocare NobelActive Conical  
 
Abutment Diameter: 
 
● NP Ø3.5mm Narrow Platform
● RP Ø4.3mm Regular Platform
 
Abutment Length:

● 3.0mm, 4.0mm, 5.0mm
 
Male Cap kits:

● Yellow Xtra-Soft Retentive Cap(0.8 lbs) 1Pcs
● Blue Strong Retentive Cap (1.2 lbs) 1Pcs
● Pink Strong Retentive Cap (2.4 lbs) 1Pcs
● Metal Housing Laboratory Processing Cap 1Pcs
● Block-Out Spacer 1Pcs
 
Locater Core Tool :

1: REMOVAL

● The male removal tip has a
pointy end useful for gripping
and removing the retainers of the
metal caps incorporated in the
overdenture.
 
2 : INSERTION

● The central part of the Locater
core tool, once detached from the
tip, has a cylindrical end specially
designed for inserting the retainers
in the metal caps.
 
3 : SCREWING

● This end of the Locater core tool,
acts as a driver for carrying the
locater abutment into the oral
cavity and as a hand driver for
fixing it to the implant.
 
● The 3 Components of the Locater Core Tool
● About The Locater Core Tool and How to Use It
● Locater 3-IN-1 Core Tool
 
● The Removal Tool Tip is used to engage and remove the Male from the Denture Cap.
● The Seating Tool is used to seat the Locater Male.
● The Anchor Driver with the Abutment Holder Sleeve carries the Abutment securely and places it onto the implant.
● Very Easy to Use. Follow these steps to utilize the 3-in-1 Locater Core Tool:
 
● Loosen the Removal End of the Core Tool. You will see a visible gap between the removal tool and seating tool.
● Insert the Removal Tool Tip into the Denture Assembly and push straight into the Male. Tilt the tool so that the sharp edge of the tip will grip the Male and pull it out of the Denture Cap.
● Once the Male is removed proceed to point the tool down and away from you. Tighten the Removal Tool Clockwise back onto the Core Tool. This will disengage the Male from the tip of the Removal Tool
● Separate the Removal Tool part of the Locater Core Tool. Use the Seating Tool to place a new Male into the empty Denture Cap