Cylinder type sensing head size
|
dia. 5.4
|
Type
|
Shielded
|
Sensing method
|
Inductive type
|
Sensing distance
|
1 mm -15% to +15%
|
Setting distance
|
0 to 0.7 mm
|
Differential distance
|
15% Max. of sensing distance
|
Sensing object
|
Ferrous metal (Sensitivity lowers with non-ferrous metals.)
|
Standard sensing object
|
Iron 5*5*1mm
|
Response frequency
|
3 kHz (average)
|
Power supply voltage
|
12 to 24 VDC (ripple(p-p) :10% Max.)
|
Operating voltage range
|
10 to 30 VDC
|
Current consumption
|
17 mA Max.
|
Control output (Output type)
|
NPN open collector output
|
Control output (Switching capacity)
|
0 to 100 mA (30VDC Max.)
|
Control output (Residual voltage)
|
2 V Max. (under load current with cable length of 2m)
|
Indicator
|
Operation indicator(red)
|
Operation mode
|
NO
|
Protective circuit
|
Surge suppressor
Power supply reverse polarity protection
|
Standard or Different frequency
|
Standard
|
Ambient temperature
|
Operating: -25 to 70 CEL
Storage: -25 to 70 CEL
(with no icing or condensation)
|
Ambient humidity
|
Operating: 35 to 95 %RH
Storage: 35 to 95 %RH
(with no condensation)
|
Temperature influence
|
+-15% Max. of sensing distance in temperature range of -25 to +70CEL
(As the basis for sensing distance of 23CEL)
|
Voltage influence
|
+-2.5% Max. of sensing distance in rated voltage range +-15%. (As the basis for sensing distance at standard power voltage)
|
Insulation resistance
|
50 M OHM Min. at 500VDC between charged parts and the case
|
Dielectric strength
|
500 VAC 50/60 Hz for 1 minute between charged parts and the case
|
Vibration resistance
|
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
|
Shock resistance
|
500m/s2 for 10 times each in X, Y, and Z directions
|
Degree of protection
|
IEC60529: IP67
Company standard: Oil-proof
|
Applicable standard (EC Directive (Low Voltage Directive))
|
EN60947-1
EN60947-5-2
|
Applicable standard (EC Directive (EMC Directive))
|
EMI: EN60947-5-2
Emission Enclosure: CISPR11 Group 1 class A
EMS: EN60947-5-2
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Burst: IEC61000-4-4
CE marking: Equipped
|
Applicable standard (CCC mark)
|
Not equipped
|
Connection method
|
Pre-wired models (Cable length: 2 m)
|
Weight (Packed state)
|
approx. 60 g
|
Material (case)
|
Brass nickel plating
|
Material (sensing surface)
|
Heat-resistant ABS resin
|
Accessories
|
Instruction manual
|