Model |
WWS |
|
Wind Turbine Input |
||
Rated input power |
2kW |
|
Rated input voltage |
48Vdc |
|
Input voltage range |
0~64Vdc |
|
Rated input current |
24A |
|
Brake by hand |
Keep press the button for 5s to unload completely, and then recover by hand. |
|
Switch “ON” the brake switch |
||
Brake by over current |
21A unload completely when reached the set current, and recover automatically after working 10mins. |
|
Brake by overvoltage |
Refer to “output overvoltage” control |
|
PV Input |
||
Rated input power |
300W |
|
Max. Open circuit voltage |
96Vdc |
|
Rated input current |
7A |
|
Reversed connection protection |
YES |
|
Charge Parameters |
||
Rated battery voltage |
48Vdc |
|
Output Parameters |
||
Rated output voltage |
48Vdc |
|
Output overvoltage point |
58Vdc |
|
output overvoltage recovery point |
it will recover automatically once it is lower than output overvoltage point. |
|
Max. Output current |
24A |
|
General Parameters |
||
Rectifier mode |
Uncontrolled rectifier |
|
Display mode |
LCD |
|
Display information |
DC output voltage, wind voltage/current/power, battery voltage, PV voltage/current/power. |
|
Lightning protection |
YES |
|
Conversion efficiency |
≥95% |
|
Static loss |
|
<1W |
Ambient temperature |
-20℃~+40℃ |
|
Humidity |
0~90%, No condensing |
|
Noise |
≤65dB |
|
Cooling mode |
Natural cooling |
|
Installation mode |
Wall-mounted |
|
Cover protection class |
IP20 |
|
Product dimension (W*H*D) |
420×440×175 mm |
|
Product net weight |
10kG |