MASTECH MS8239C AC DC Voltage Current Capacitance Frequency Temperature Tester
   
Description

Brand new MASTECH MS8239C 9999 Ground EARTH RESISTANCE Tester Meter 0.1 ohm with all accessories + portable bag compared with FLUKE F1625 kit

Brand new New with one year USA warranty
 

General specifications

l          Operating environment and condition: 600V CAT., pollution grade: .

Elevation < 2000 m

Environment temperature and humidity: 0~40°C,  <80% RH (do not use meter when temperature <10°C).

l          Storage temperature and humidity: -10~60°C, <70% RH (remove the battery).

l          Temperature coefficient: 0.1´ Accuracy/°C(<18°C or >28°C).

l          The maximum allowable voltage between measurement end and ground: 600V DC or 600V AC RMS.

l          Fuse protection:  grade mA: fuse F400mA/500V

l                         grade 10A: fuse F10A/500V

l          Sampling rate: about 3 times/s.

l          Display: 3 3/4 bits of digit LCD display.

l          Over-range indication: LCD will show “OL”.

l          Low battery indication: When the battery voltage is lower than the normal operating voltage, “” will display on the LCD display.

l          Input polarity indication: automatically display “-” symbol.

l          Power supply: AAA 1.5V batteries.

 

Accuracy indicators

Accuracy: ±(% of reading + digits) with one year of warranty.

Reference conditions: environmental temperature is from 18°C~28°C, relative humidity is not more than 80%.

 

DC voltage

Measuring range

Resolution

Accuracy

400mV

0.1mV

±(0.5% of reading +3 digits)

4V

0.001V

40V

0.01V

400V

0.1V

600V

1V

Input impedance: 10M W

Maximum input voltage: 600V DC or AC (RMS)

 

AC voltage

Measuring range

Resolution

Accuracy

4V

0.001V

±(1.2% of reading +5 digits)

40V

0.01V

400V

0.1V

600V

1V

Input impedance: 10M W

Maximum input voltage: 600V DC or AC (RMS). 

Frequency response: 40Hz~400Hz, sine wave RMS (average response)

15

Resistance

Measuring range

Resolution

Accuracy

400W

0.1W

±(0.8% of reading +5 digits)

4kW

0.001kW

40kW

0.01kW

400kW

0.1kW

4MW

0.001MW

40MW

0.01MW

Overload protection: 600V DC or AC (RMS)

Capacitance

Measuring range

Resolution

Accuracy

5nF

0.001nF

±(3.0% of reading +5 digits)

50nF

0.01nF

500nF

0.1nF

5uF

0.001uF

50uF

0.01uF

100uF

0.1uF

Overload protection: 600V DC or AC (RMS)

Diode and continuity measurement

Function

Measuring range

Resolution

Accuracy

Diode Test

1V

0.001V

Display approximate diode forward voltage drop value.

 

When built-in buzzer sounds, the resistance to be tested is less than 60W.

Open circuit voltage: about 0.5V

Overload protection: 600V DC or AC (RMS)

 

 

Direct Current

Measuring range

Resolution

Accuracy

400uA

0.1uA

±(1.0% of reading +5 digits)

4000uA

1uA

40mA

0.01uA

400mA

0.1uA

10A

10mA

±(2.0% of reading +10 digits)

Overload protection: grade mA: Fuse (F400mA/600V) protection; grade 10A: Fuse (F10A/500V) protection.

Maximum input current: grade mA: 200mA DC or AC RMS; grade 10A: 10A DC or AC RMS

When measured current is greater than 2A, the continuous measurement time cannot be more than 2 minutes. Disconnect the current and wait 10 minutes before making another measurement.

AC current

Measuring range

Resolution

Accuracy

400uA

0.1uA

±(1.2% of reading +5 digits)

4000uA

1uA

40mA

0.01uA

400mA

0.1uA

10A

10mA

±(2.5% of reading +10 digits)

Overload protection: grade mA: Fuse (F400mA/600V) protection; grade 10A:  Fuse (F10A/500V) protection.

Frequency response: 40Hz~400Hz, sine wave RMS (average response)

Maximum input current: grade mA: 200mA DC or AC RMS; grade 10A: 10A DC or AC RMS

When measured current is greater than 2A, the continuous measurement time cannot be more than 2 minutes. Disconnect the current and wait 10 minutes before making another measurement.

 

 Accessories:

1) A pair of test leads;

2) English manual;

Shipping: US order will ship from USA, thank you

Payment

Paypal

   
eBay Cross Border Trade powered by Channel Effect