50A:

 

  • Function
    1. Electrical parameter measurement function (voltage, current, active power, energy)
    2. Voltage alarm function (over voltage alarm threshold, backlight and voltage flashing to alarm)
    3. The reset function of energy key
    4. Store data when power off
    5. Large-screen LCD (display voltage, current, active power, energy at the same time)
    6. Backlight function
  • Appearance and Key function
  • Display Interface
    Display interface is large-screen LCD, it can display voltage, current, power, energy parameters at the same time
  • Display format
    1. Power: test range: 0~10kW
    - Within 1KW, the display format is 0.0~999.9W
    - 1KW and above, the display format is 1000~9999W
  • 2.Energy: test range: 0~9999kWh
    - Within 10KWh, the display format is 0~9999Wh
    - 10kWh and above, the display format is 10~9999kWh
  • 3.Voltage: test range: 6.5~100V
    Display format: 6.50~99.99V
  • 4.Current: test range: 0~50A
    Display format: 0.00~49.99
  • Key
    1.Backlight control
    Short press the key to turn on or off the backlight, the backlight has memory function, it can store the on or off state when power off
  • 2.Reset energy
    Step1: Long press the key until the power display area display “CLr”, then release the key
    Step2: At this moment, the energy is flashing to prompt this is the energy reset state, if short press the key again, then the energy value is cleared and exit the reset flashing state
    Step 3: If there is no operation within 5 seconds, it means the energy value is not cleared and will exit the reset state
  • 3.Set voltage alarm threshold
    Step1: Long press the key until the power display area display “SET”, then release the key
    Step2: After enter this state, the voltage area display the current high voltage alarm value, the current area display the current low voltage alarm value and the last digit begin to flash, then you can short press to plus 1, when there is no operation over 3 seconds, it will switch the digit position automatically, from the high voltage alarm value to the low voltage alarm value, there are total six digits, the range of the voltage alarm threshold is 6.5-99.9V
    Step3: After finish the setting, long press the key until the screen display “PASS”,that means you set successfully and will exit the setting state automatically
  • 4.Choose measuring range
    Step1: Long press the key until the power area display “Curr”, then release the key
    Step2: At this moment, the current area display “100A”, short press the key to switch between“100A”and “50A”, to prompt the range of the external shunt is 100A/75mV or 50A/75mV, please note that this meter can only use these two specification shunt
    Step3: Long press the key to exit the setting state or after no operation within 3 seconds it will store automatically and exit the setting state
  • Precautions
    1.This module is suitable for indoor, please do not use outdoor
    2.Applied load should not exceed the rated voltage, current
    3.Wiring order can’t be wrong
  • Specification parameters
    1.Working voltage: 6.5-100VDC
    2.Test voltage: 6.5-100VDC
    3.Rated power: 50A/10000W

    4.Measurement accuracy: 1.0 grade




    Recently had buyers who had the connection error in dc table (with 50A or 100A external shunt), so briefly refocused to explain here, if buyers not according to the physical wiring diagram user contrast connection, a burn table shall not be liable for any situation. Note as following:
  • 1. The No-Load condition (voltage measurement, don't connect the shunt and load)
    Dc power supply is negative table from the power supply/positive and negative electrode of test power supply are ok to directly from you.
    2. The loading status (have connected the shunt and load)
    Pay special attention to dc form cathode anode cannot connect the cathode of the power supply directly ,need to go through an external shunt terminal (although see the wiring diagram from the back of the meter is in a line, but the result is completely different)!

 

 

20A:

  • 1. Electical parameter measurement function(Voltage, current,active power, energy)
    2. Voltage alarm function(over voltage alarm threshold, backlight and voltage flashing to alarm)
    3. The reset function of energy key.
    4. Store date when power off.
    5. Large-screen LCD (display voltage, current, active power, energy at the same time)
    6. Backlight function.
  • Display interface
    Display interface is large-screen LCD (display Voltage, current, power, energy parameters at the same time)
  • Display format:
    1. Power: test range: 0-2KW
    Within 1kw, the display format is 0.0-999.9W;
    1kw and about, the display format is 1000-2000w.
    2. Energy: test range: 0-9999kwh
    Within 10kwh, the display format is 0-9999wh;
    10kw and about, the display format is 10-9999kwh.
    3. Voltage: test range: 6.5-100v
    Display format: 6.50-99.9v
    4. Current: test range: 0-20A
    Display format: 0.00-20.00
  • Precautions:
    1. This module is suitable for indoor, please do not use outdoor.
    2. Applied load should not exceed the rated voltage, current.
    3. Wiring order can't be wrong.
  • Specifications:
    Type: PAEM-031
    Working voltage: 6.5-100VDC
    Test voltage:6.5-100VDC
    Rated power: 20A/200W
    Meaurement accuracy: 1.0 grade
    Size: 89.6*49.6*24.4mm(Length*Wide*High)
    LCD screen: 51*30mm(Length*Wide)
    Color: Black


100A:

 

  • Widely Use in cars, boats, motorcycle and Testing Devices for measuring voltage and current
    Widely used in equipment and electromechanical device
    Monitoring battery & electrical system, solar, Wind, HHO System
  • The New version details
    Specifications
    - The working voltage: 6.5 ~ 100VDC
    - Max power: 100A/10000W
    - Measurement precision: class 1
  • About function
    - Measure and monitor the electrical parameters (voltage, current, kWh, watt)
    - Overload alarm function (more than watt alarm threshold , backlight flashing)
    - Power alarm threshold preset function (can set up their own power alarm threshold)
    - Power(kWh) button reset function
    - When power off, store the data, when on, continue the date
    - Large screen LCD liquid crystal screen full display function (voltage, current, kWh, watt)
    - Backlight function
  • About Display
    Display interface. By the large screen LCD display LCD monitor voltage and current, kWh, watt, electric parameters
    - Watt: the measurement range of 0~10kW
    less than 1kW: 0.0~999.9W
    less than 10kW: 1000~9999W
    - kWh: the measurement range of 0~9999kWh
    less than 10kWh: 0~9999Wh
    more than 10kWh:10~9999kWh
    - The test voltage range of 6.5-100V DC
    Display format 6.50~99.99V
    - Current test range: 0~100A
    Display format 0.00~99.99A
  • About Button
    - Backlight control
    Can turn on/off backlight by short press
    - Power rese
    Step 1: long time press the button ( about 5 seconds), til display flicker, then release the button
    Step 2: if short time press the button again, then power(kWh) reset zero and exit flicker
    Step 3: if long press button for 5 seconds until it is no longer flicker, power(kWh) data is not cleared and exit
    - Set the alarm (watt
    Step 1: long press the button, till the LCD screen display "SET CLr", release the button
    Step 2: show the alarm(voltage) value, short time press, value(number) increase. don't press the button for 3 seconds, the setting switch to other bit
    Step 3: long time press the button(about 5 seconds) ----> save the threshold voltage value
    Threshold setting watt range: 6.5v-99.99v

 

 

 

 

Package includes:

 

1pcs DC 20/50/100A LCD Digital Volt Voltage Watt Current Power Meter Ammeter Voltmeter

 

 

Payment

Payment

Payable To

Note

PayPal

Paypal

All payments are due within 7 days of the close of auction. Failing to do so, non-paying bidders will be reported to eBay.

Shipping Policy

Delivery Time

We ship to worldwide, it usually takes 10-30 Business Days to delivery.

Shipping address

We ship to your PayPal address. Please, make sure to provide us with correct, precise, and detailed shipping Address.

Send Time

Items will be shipped within 1 to 3 business days upon payment received or cleared.

Note

If you don't receive items over 30 business days, please notify us via eBay message.

Return Policy
We appreciate your business and offer an instant 7 days return policy.(7 days after receive the item). The returned item has to be in its original condition. We are able to refund your money without shipping cost.  
Contact us
For anything about product, price, shipping or order status, please contact us via eBay message.
We love positive feedback and 5 scores DSR. We will leave it for everyone that leaves it for us.  

 

DataCaciques