MS6310 Combustible Gas Detector 10%-40% for Methane Solid State easy to use
New MASTECH MS6310 Combustible Gas Detector
 
1.Features
l Quickly identifies and pinpoints gas leaks
l One hand operation and manual regulate sensitivity
to eliminate background gas level
l High sensitivity
l Visible and audible alarm at 10% ~ 40% LEL
l Resume calmness approx 7~10 minutes in pure air
l Power supply 6V( 4דAA”1.5V alkaline batteries)
2.Gas Detected
l Natural Gas
l Methane
l Ethane
l Propane
l Butane
l Acetone
l Alcohol
l Ammonia
l Steam
l Carbon Monoxide (not to quantify)
l Gasoline
l Jet Fuel
l Hydrogen Sulfide
l Smoke
l Industrial Solvents
l Lacquer Thinner
l Naphtha
3.Specification
Specifications
Range
Sensitivity
50 ppm methane
Sensor
Solid State
Alarm
10% ~ 40% for Methane
Warm-up
Approx. 2minute
Response Time
< 2 seconds (10%~40% LEL)
Duty Cycle
Intermittent
Battery life
Approx.9 hours continuous use typical
Operating Temperature
0 ~50℃
Operating Humidity
10 ~90% RH (non-condensing)
Dimensions
172×70×46 mm
Functions description:
l Quickly recognize and determine the flammable gas leakage location
l Manual sensibility adjustment
l High sensibility
l Visible sound and light alarm
Important Notice:
l Please use the product in pure air after preheating.
l Please replace battery immediately when green light flashes.
l Please power off when not using to prevent battery discharge.
 
Main Parameters:
l Resolution: 50 ppm (methane)
l Alarm range: 10%—40% LEL
l Response time: < 2S (40% LEL)
Use method:
Red light: alarm detection indicator
Green light: power indicator and low voltage power supply alarm indicator
l In pure air, press the power key to start up. The green light will turn on.
l Rotate the knob clockwise to the lowest sensitivity position. Wait for at least 2 minutes for preheating.
 
Note: In the preheating process, the red light will flash uninterruptedly along with alarm sound, which is due to the sensor not being stable. You may ignore this condition.
 
l After preheating, rotate the knob counter-clockwise to the critical emergency alarm set point. At this time, the detection sensitivity is at maximum. The red light will not light without the alarm. . The red light will light only occasionally. This does not affect meter performance.
l Hold the meter with one hand. Do not adjust the knob now. Move the sensor slowly close to the detected gas. When the meter detects a certain concentration of flammable gas, the red light will flash and the alarm will sound. The greater the concentration is, the more intense the alarm will be.
l After the completion of detection, rotate the knob clockwise to the lowest sensibility position. Press the power supply key to power off, and the green light will turn off.
 
Specifications:
l Operating temperature: 0~50oC
l Operating humidity: 10 ~90% (above freezing)
l L×W×H: 172×70×46 mm
l Power supply mode: 4x1.5V AAA battery
l Weight: 330g (Not includes batteries)