Lot Of 50 New EYE LIGHTING 50EYE124BGJJF 

Outdoor Locking Photoelectric Photo Light Sensors

SHIPS TO ADDRESSES WITHIN THE LOWER 48 STATES ONLY PLEASE

Applications Include LED, HID, Induction, Fluorescent or Halogen Systems; Roadways; High Surge Areas; Street Lighting; Parking Lots; Security Lighting

Rated 105-305VAC for 120, 208, 240 and 277VAC systems
  
Will operate down to 90VAC
  
Control rated -40° to +70°C. Base rated for 105°C interface temperature per C136.10
  
FR4 fiberglass printed circuit board
  
Silicon light sensor
 
2-5 second Turn OFF delay
  
ANSI Standard 1.5±0.5 fc Turn ON, Turn OFF is 1.5 times the Turn ON level
 
Surge protection: Dual 25mm 420 joules. All controls are rated for multiple surges at one minute intervals
 
 >0.070 inch (1.78 mm) cover thickness
 
Solid brass legs
 
Load rating: 1800VA HID ballast or 1000W (10A) electronic LED driver 
 
Fail OFF design series » Use Fail OFF controls in situations where fixture life may be compromised by being ON during the day in unlikely event of a photocontrol failure
 
Upgrade from standard control with dual 420 MOV’s

Sealed relay 

Cover Color - black 
 
50-piece carton quantity 

120-277VAC, two 25 mm MOVs each rated 420 joules for multiple surges. Black cover. Fail OFF.

Sample Specification for Silicon Multivolt RoHS Compliant Photocontrols – BG Series 1. 
Photocontrol: Shall be a Locking Type (aka twist lock). 2. 
Line voltage: 105-305VAC @ 50/60 hertz. 3. 
Load rating: Shall be at least 1800VA. Control must be able to operate incandescent, ballast, LED and lighting contractor type loads. 
4. Control relay: Shall be sealed. 
5. Turn ON: Shall be 1.5±0.5 fc. Turn OFF shall be 1.5 times the turn ON level. 
6. Photosensor: Sealed silicon sensor. Cadmium sulphide cells are not acceptable. 
7. Failure mode: Control will fail OFF per ANSI definition. Relay must use normally open contacts. 
8. Time delay: Control must have instant ON and 2-5 seconds “OFF” delay. 
9. Surge protection: Each MOV shall be rated a minimum of 420 joules and 9500 amp surge.
10. Housing: Shall be black, opaque and of an impact and UV resistant material. Impact resistance of housing shall be greater than 1.0 ft-lbs at -20°C. Top of cover 0.070 inch (1.78 mm) or thicker. 
11. Drop test: Control must be capable of withstanding a drop of 3 feet (1 m) to a concrete floor without causing damage to the housing or changing electrical operation. 
12. Markings: The following must appear on the control: month/year of manufacture, model description, operating voltage range and load rating. 
13. Power consumption: Shall consume 0.5 watts or less at 120VAC. 
14. Environmental: Shall be RoHS compliant. It shall not contain lead, cadmium, mercury or hexavalent chromium. Pigments in plastic parts shall not contain bromine compounds or heavy metal pigments.