Package Contents
100% Brand New
1 XModule

Features: 

USB to MBUS master module

Please use USB driver we provided, otherwise it will not communicate properly!


HTB1tk0nN3HqK1RjSZFgq6y7JXXah
Applications
• Smart energy meter, gas meter, heat meter, smart grid meter reading application with MBUS
• Smart home control, fire alarm and linkage network applications with MBUS
• Central air conditioning control with MBUS, smart sensor network application
Features

1.2 Ports MBUS interfaces (the same MBUS is divided into two groups) to facilitate the connection of multiple slave devices

2.ully complied with MBUS international standards and national standards

3.
3. Compatible with Win11 and below systems.
MAC OS SYSTEM SUPPORT
Support for Linux systems
Support Android

4.USB power supply, no external power supply required

5.USB hot pluggable, safe and stable, long communication distance, communication distance greater than 1200M

6.Portable size, easy to carry out on-site debugging; The shell does not have any text or pattern logo, and customers can engrave the logo by themselves.

7.The module has no spontaneous self-receiving and bit error phenomenon within the normal load range.

8.Short circuit protection low power function.

After the bus is short-circuited, the USB indicator is turned off, and the bus is automatically shut down internally to enter the protection state.
It detects whether the bus is short-circuited every 4 seconds.

Once the short-circuit is automatically recovered, the USB indicator is automatically restored. The module enters protection and low power consumption and the computer USB will not be dead (If USB dead, it needs to restart the computer).
 Hint: Since there is voltage on the MBUS bus, the bus protection function is essential for the converter. Unprotected converters may cause the computer's USB serial port to crash and may cause permanent damage to the USB.


HTB1tY4lN8LoK1RjSZFuq6xn0XXat

 

9.        Communication baud rate 300~9600, maximum 19200bps.

10. Take 25 standard MBUS slave devices according to the load capacity
The bus voltage within the MBUS standard range is provided, and the following is the MBUS standard description:




19200 communication waveform:


ge
 

Cautions:

1.   The MBUS host module can only communicate with the slave module. The master module cannot communicate with the master module. The slave module cannot communicate with the slave module. There can only be one master on the same MBUS bus

2.  USB power supply capacity is limited, MBUS bus can load up to 10 standard slave devices, too many slave devices will make the module into overload protection state.

3.  Bus protection function, the module will not be damaged after the MBUS bus is short-circuited, but try to avoid long-term short circuit.

4.  All interfaces of this module cannot touch the strong electricity.

5.       If you encounter problems during the debugging process, you can purchase a slave module to test with the master module, and communicate with other devices after confirming that there is no problem.


USB to MBUS slave module


QQ20190424181307

This module is used for MBUS master and slave module communication debugging, and the module is used as the slave to communicate with the host terminal through the USB terminal. The integrated chip FC722 is used as the slave end, which is different from the TSS721A without self-receiving, and has lower bus leakage current than the discrete device circuit integrated chip.The module MBUS signal is completely isolated from the USB signal, so you don't have to worry about MBUS high level damage to the computer USB interface! The MBUS signal circuit takes power from the MBUS bus and has nothing to do with USB!

Features:

1, fully in line withM-BUSInternational standards and national standards

2,Bus current200uA-3mAcontinuous

3, bus voltage12V-42V

4,Enhanced5V, 3.3VRegulated output

5, 300-9600BPSCommunication rate

6,stand byUART,High stability


  Application areas:

    Communication debugging of master-slave module for simulating intelligent water meter gas meter heat meter reading meter application
    Analog smart grid automatic meter readingApplication master-slave module communication debugging
    Analog smart home control networkApplication master-slave module communication debugging
    Simulated fire alarm and linkage networkApplication master-slave module communication debugging
    Analog central air conditioning control systemApplication master-slave module communication debugging
    Analog smart sensor networkApplication master-slave module communication debugging

sample graph:


Master-slave docking testsged
 




Am 08.12.21 hat der Verkäufer die folgenden Angaben hinzugefügt:




Am 10.11.2022 hat der Verkäufer die folgenden Angaben hinzugefügt:


DataCaciques