Notice:
The standard package don't include batteries.
Because,the international air shipping forbid to ship liquid,powder and batteries,
we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.
At the same time, please forgive us that we are unable to provide the English user manual.
If you need it, please contact the customer service after purchase.
Thanks for your support!

1.2 features
1.2.1 Basic functions:
Waveform real-time display (4 voltage /4 current).
True effective values of voltage and current.
★ DC voltage components.
Peak current and voltage.
The maximum/minimum effective value of current and voltage half cycle.
★ Phoror diagram display.
★ Each phase harmonic measurement, up to 50 harmonics.
★ The column chart shows the harmonic content of each phase current and voltage.
Total Harmonic Distortion (THD).
★ The active/reactive/apparent power value and total value of each phase.
★ The value and total value of active power/reactive power/apparent electric energy of each phase.
★ Transformer K factor.
★ Power factor (PF) and COSφdisplacement power factor (DPF).
Short-term voltage flicker.
Three-phase unbalance (voltage and current).
 
1.2.2 Capture and record function:
◆ Transient capture function:
It can capture and detect instantaneous changes of voltage and current parameters, including voltage and current fluctuation, voltage and current sudden rise, sudden drop, short interruption, transient overvoltage, impulse current, current and voltage instantaneous distortion.
The instrument can store up to 150 sets of transient waveforms simultaneously.
◆ Start current monitoring:
It can monitor the inrush current of the line, and monitor the start current of the electrical equipment when it is started, which helps to design the installed capacity correctly.
It can display the rise/fall curve of the effective value during the startup process, the envelope curve of the startup current, the waveform of the 4-way current and 4-way voltage.
After triggering, it can record about 100s, and store all instantaneous values of current and voltage and waveform curves within 100s of each cycle.
◆ Trend chart record storage function:
All test parameters of the basic test function (URMS, UTHD, UCF, UUNB, HZ, VRMS, VTHD, VCF, VUNB, PST, ARM, ATHD, ACF, AUNB, KF, W, VAR, VA, PF, COSφ, Tan φ), voltage 50 harmonics,
The 50 harmonics of current are recorded with 123 parameters in total, and the trend graph is generated, which can be recorded for a long time according to the need.
(Select 20 parameters at the same time and record once every 5 seconds, which can record for about 300 days)
◆ Alarm function:
The selected parameters can be set limits according to needs to monitor whether they are out of limit. Alarm logs will be generated when they are out of limit, such as voltage over voltage, current over current, unbalance degree over limit, certain harmonic ratio over limit, frequency over limit, active power over limit, total harmonic distortion over limit, etc. Up to 40 groups of alarm monitoring parameters can be set.
Each group can set different monitoring parameters (including a total of 123 different parameters for 50 harmonics) and limits, and can set the shortest time beyond the limit.
Up to 12,800 groups of alarm log records can be stored.
Screen capture function:
In any test page can take a screenshot to store the current screen picture, at the same time automatically save the record time and the test mode.
For example, you can save screen pictures of current and voltage waveforms, harmonic histograms, phasor graphs, and so on.
Up to 60 groups of screenshots can be saved simultaneously.
 
1.2.3 Other functions
◆ Communication function:
Through USB communication with the computer, the monitoring software can display the waveform of the power quality analysis test in real time, read the detected and captured transient waveform, trend chart records, alarm logs, screenshots, etc., and display on the computer.
◆ Setting function:
The user can set the time and date, the contrast and brightness of the display, and the corresponding color of each phase waveform curve in the instrument.
The wiring mode and power grid type of the instrument can be set.
Different current clamp and different voltage test ratio can be selected.

1.3 Technical Specifications

1.3.1 Reference conditions and working conditions

Amount of influence

Test project

Benchmark conditions

The working conditions

The environment temperature

All the parameters

(23±2)℃

-10℃~40℃

Relative humidity

All the parameters

40%~60%

<80%

Phase voltage

All the parameters

(100±1%)V

1.0V~1000V

Line voltage

True effective value of line voltage

(200±1%)V

1.0V~2000V

current

Measure the true effective value of the current

(5±1%)A

10mA~3000A

The grid frequency

All the parameters

50Hz±0.1Hz

40Hz~70Hz

Phase shift

harmonic

Measure the active power

      Cosφ=1

Cosφ:0.2~1.0

Measure reactive power Reactive power

      Sinφ=1

Sinφ:0.2~1.0

Voltage unbalance

All the parameters

<0.1%

0.0%~100%

Instrument operating voltage

All the parameters

<10%

0.0%~100%

External electrical field, magnetic field

All the parameters

 DC9.8V±0.1V

 DC9.5V~10.5V

Position of conductor to be measured

All the parameters

Should be avoided

Amount of influence

Measure the parameters related to the current

The measured wire is located at the approximate geometric center of the jaws


1.3.2 General Specifications

The power supply

Rechargeable lithium battery pack 9.6V, external charger.

Battery level indicator

Battery symbol 5 grid shows the power, when the battery power is too low, prompt 1 minutes after the automatic shutdown.

Working current

About 490mA, full charge of the battery for about 8 hours continuous operation.

Display mode

LCD color screen,640dots×480dots, 5.6 inches, 116mm×88mm display field

Size of jaws (optional)

008B small tip current clamp: 7.5mm×13mm;

Size of instrument

040B round mouth type current clamp: 35mm×40mm;

The channel number

068B round mouth type current clamp: 68mm×68mm;

Line voltage

300F flexible coil current sensor (with integrator) : Φ300mm.

Phase voltage

Length width thickness: 240mm×170mm× 68mm.

current

4 channels voltage, 4 channels current.

frequency

1.0 V to 2000 V.

Electric power parameter

1.0 V to 1000 V.

Electricity parameter

008B current clamp: 10mA ~ 10.0A;

harmonic

040B current clamp: 0.10A ~ 100A;

Total harmonic distortion

068B current clamp: 1.0A ~ 1000A;

Expert mode

300F flexible coil current sensor (with integrator) 10A ~ 3000A

Number of transient record groups

40 hz ~ 70 hz.

Voltage flicker

W, VA, VAR, PF, DPF, cosine φ, tanφ.

Start current mode

Wh, Varh, Vah.

Three-phase unbalance

Yes, 0 to 50 times.

record

There are 0 to 50 phases.

Minimum maximum record value

YES.

The alarm

150 sets.

peak

YES.

Capture capacity

Yes, 100 seconds.

The menu language

YES.

Communication interface

300 days (20 parameters recorded simultaneously, 1 point every 5 seconds).

Automatic shutdown

backlit

Yes, the maximum and minimum values that can be measured over time.

40 different types of parameter selection, 12,800 sets of alarm logs.

Quality of the instrument

YES.

Voltage test line length

Current clamp wire length

Operating temperature and humidity

Storage temperature and humidity

The input impedance

pressure

insulation

60.

Chinese, English.

USB.

In alarm/trend chart record/transient capture mode (wait or in progress), the instrument does not shut down automatically.

In other test mode, no button operation within 15 minutes, prompting 1 minute automatic shutdown.

Yes, suitable for dark places and night use.

Host: 1.6kg(with battery);

structure

008B small tip current clamp: 170g×4;

Suitable for safety

040B round mouth type current clamp: 190g×4;

The power supply

068B round mouth current clamp: 510g×4;

Battery level indicator

300F flexible coil current sensor (with integrator) : 330g×4;

Working current

Test line and power adapter: 900G;

Display mode

Total weight: about 9.2kg(including packaging).

Size of jaws (optional)

3 m.

Size of instrument

2 m.

The channel number

- 10 ℃ to 40 ℃;Below 80% Rh.

1.3.3 Description of instrument accuracy (excluding current sensor)

The following data are presented respectively under reference conditions and on the basis of an ideal current sensor that is completely linear and has no phase displacement.

measurement

Range

Display resolution

Within the reference range

Maximum error

frequency

40Hz~70Hz

0.01 Hz

±(0.03)Hz

True effective value of phase voltage

1.0V~1000V

Minimum resolution 0.1V

±(0.5%+5dgt)

True effective value of line voltage

1.0V~2000V

Minimum resolution 0.1V

±(0.5%+5dgt)

Dc voltage

1.0V~1000V

Minimum resolution 0.1V

±(1.0%+5dgt)

True effective value of current

10mA~3000A

Minimum resolution 1mA

±(0.5%+5dgt)

Peak phase voltage

1.0V~1414V

Minimum resolution 0.1V

±(1.0%+5dgt)

Peak line voltage

1.0V~2828V

Minimum resolution 0.1V

±(1.0%+5dgt)

The peak current

10mA~4200A

Minimum resolution 1mA

±(1.0%+5dgt)

The peak factor

Active power

1.00~3.99

0.01

±(1%+2dgt)

4.00~9.99

0.01

±(5%+2dgt)

Reactive power

inductive

0.000W~9999.9kW

Minimum resolution

0.001 W.

±(1%+3dgt)
Cosφ≥0.8

±(1.5%+10dgt)
0.2≤Cosφ<0.8

&

capacitive

0.000VAR~
9999.9kVAR

Minimum resolution

0.001 VAR

±(1%+3dgt)
Sinφ≥0.5

±(1.5%+10dgt)
0.2≤Sinφ<0.5

Apparent power

0.000VA~
9999.9kVA

Minimum resolution 0.001VA

±(1%+3dgt)

The power factor

Active power

-1.000~1.000

0.001

Minimum resolution

±(1.5%+3dgt)
Cosφ≥0.5

±(1.5%+10dgt)
0.2≤Cosφ<0.5

Reactive power

inductive

0.000Wh~
9999.9MWh

0.001 Wh

Minimum resolution

±(1%+3dgt)
Cosφ≥0.8

±(1.5%+10dgt)
0.2≤Cosφ<0.8

&

capacitive

0.000VARh~
9999.9MVARh

0.001 VARh

Minimum resolution

±(1%+3dgt)
Sinφ≥0.5

±(1.5%+10dgt)
0.2≤Sinφ<0.5

Apparent power

0.000VAh~
9999.9MVAh

0.001 VAh

±(1%+3dgt)

Phase Angle

-179°~180°

1 °

±(2°)

Tan phi

-32.76~32.76

Minimum resolution 0.001

φ:±(1°)

(VA VA 50 or higher)

-1.000~1.000

0.001

φ:±(1°)

Displacement power factor

0.0%~99.9%

0.1%

±(1%+5dgt)

(DPF)

Harmonic than

-179°~180°

1 °

0.1%

±(3°) harmonics 1 ~ 25 times

±(10°) harmonic 26 ~ 50 times

Contains 1 to 50 times

0.0%~99.9%

0.1%

±(1%+5dgt)

(Vrms>50V)

0.0%~99.9%

0.01

±(1%+10dgt)

Harmonic Angle

1.00~99.99

0.1%

±(5%)

(Vrms>50V)

0.0%~100%

Display resolution

±(1%)

 
1.3.4 Current clamp characteristics

Type of current clamp

True effective value of current

True effective value of current

Maximum error

Maximum error of phase Angle φ

  008B

10mA~99mA

±(1%+3dgt)

±(1.5°),Arms≥20mA

100mA~10.0A

±(1%+3dgt)

±(1°)

040B

0.10A~0.99A

±(1%+3dgt)

±(1.5°)

1.00A~100A

±(1%+3dgt)

±(1°)

068B

1.0A~9.9A

±(2%+3dgt)

±(3°)

10.0A~1000A

±(2%+3dgt)

±(2°)

300FType of current clamp

Current sensor

10A~99A

±(1%+3dgt)

±(3°)

100A~3000A

±(1%+3dgt)

±(2°)

 

DataCaciques